Product Details:
Payment & Shipping Terms:
|
The 1734-IB4D is the only four-point DC input slice that tells you whether the wiring is wrong before the machine runs: it monitors sensor source voltage per point and reports both an open wire and a short circuit in the produced data.
Diagnostics are per input and self-resetting. A short clears and the point re-energises without a power cycle; an open wire clears when the sensor circuit closes again. Nothing latches, so the module reports the present condition rather than a history.
| 1734-IV4 | 4 sourcing 24V DC inputs, 2...15 mA per point, 31.8 g | IN STOCK |
| 1734-IV8 | 8 sourcing 24V DC inputs, 1.2 W dissipation, 32.3 g | IN STOCK |
| 1734-IB4D | 4 sinking 24V DC inputs with open-wire and short circuit diagnostics | IN STOCK |
Number of inputs |
4, sinking, one group of 4 |
Diagnostics |
Short circuit and open wire, per input |
Voltage, on-state, nom |
24V DC |
Voltage, on-state range |
11...28.8V DC |
Voltage, off-state range |
-3...+5V DC |
Current, on-state range |
2.0...15.0 mA |
Current, off-state, max |
1.5 mA |
Short circuit threshold |
Above 200 mA the input fault is asserted and the LED turns solid red |
Open wire threshold |
Below 0.5 mA the input fault is asserted and the LED blinks red |
Input filter time |
Independently settable per input in 1 us steps, rounded to 333 us; 0...65,535 us, default 1000 us |
POINTBus current, max |
50 mA @ 5V DC |
Power dissipation, max |
0.6 W @ 28.8V DC |
Thermal dissipation, max |
1.9 BTU/hr @ 28.8V DC |
Isolation voltage |
50V DC (continuous), reinforced insulation, tested at 1000V DC for 60 s, field side to system |
Field power bus supply |
24V DC nominal, 10...28.8V DC |
Reverse polarity protection |
Yes |
Terminal base |
1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS - not compatible with 1734-TB3, 1734-TB3S, 1734-TOP3 or 1734-TOP3S |
Terminal base screw torque |
0.8 Nm (7 lb-in) |
Wire size |
0.25...2.5 mm2 (22...14 AWG), 75 deg C, 1.2 mm insulation max |
Keyswitch position |
1 |
Dimensions, HxWxD |
56 x 12 x 75.5 mm |
Weight, approx |
36 g |
Temperature, operating |
-20...55 deg C (-4...131 deg F) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN029B-EN-E (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Short circuit: the sensor source voltage for each input is protected by a thermally actuated smart-power device. Above 200 mA the fault bit is set and the input LED turns solid red. Open wire: current in the source-voltage leg is monitored, and below 0.5 mA the fault bit is set and the LED blinks red. Both are per input, and both reset automatically when the condition clears.
A dry contact in series with the source voltage draws no current while open, which looks exactly like an open wire. Rockwell's instruction is explicit: wire the contact between SSV and the input, and add a shunt resistor across the contact so more than 0.5 mA always flows. Without the resistor, every healthy open contact would flag a fault - which is why open-wire detection can be disabled per point for unused inputs.
Each input has its own filter from 0 to 65,535 us in 1 us steps, rounded to the nearest 333 us, with a 1000 us default. That granularity lets a high-speed limit switch on one point and a level float on another share a slice without compromising either. It also means the scan time does not have to be set for the slowest device.
The protection device trips above 200 mA per input and resets thermally. A solenoid wired into the same field supply can drag the rail down before the PTC acts, so keep the diagnostics input supply separate from output loads - the module tolerates the fault, but the rest of the panel does not.
The IB4D fits 1734-TB, TBS, TOP and TOPS bases and is explicitly not compatible with TB3, TB3S, TOP3 or TOP3S. On a rack built with three-row bases for a 36-point slice, this module physically cannot be inserted - check the base family before ordering the diagnostic version.
What diagnostics does 1734-IB4D provide?
Per-input short circuit and open wire detection. Above 200 mA the LED is solid red; below 0.5 mA it blinks red. Both conditions reset automatically when they clear.
How is open-wire detection used with dry contacts?
Wire the contact between the SSV terminal and the input, and fit a shunt resistor across the contact so the SSV leg always carries more than 0.5 mA.
Can open-wire diagnostics be switched off?
Yes, per point through the EDS file, GSD file or Logix profile, or for all four points at once from the configuration software. All four are enabled by default.
What is the input filter range?
0 to 65,535 us per input, settable in 1 us steps rounded to 333 us, default 1000 us.
Which bases are compatible?
1734-TB, 1734-TBS, 1734-TOP and 1734-TOPS. It is not compatible with 1734-TB3, TB3S, TOP3 or TOP3S.
How much POINTBus current does it draw?
50 mA at 5V DC, with 0.6 W dissipation at 28.8V DC and 50V reinforced isolation type tested at 1000V DC for 60 s.
The table reproduces the sibling list this page publishes, with each catalog number put in the class of module it is; the paragraph after it places this part in that ladder, and the arithmetic at the end uses this page's own POINTBus figure against the 1.0 A budget the adapters print.
| Catalog number | What the published line says | Class of module |
| 1734-IV4 | 4 sourcing 24V DC inputs, 2...15 mA per point, 31.8 g | Digital input |
| 1734-IV8 | 8 sourcing 24V DC inputs, 1.2 W dissipation, 32.3 g | Digital input |
| 1734-IB4D | 4 sinking 24V DC inputs with open-wire and short circuit diagnostics | Digital input, diagnostics |
1734-IB4D is the diagnostic member of the input line: the same four sinking inputs as 1734-IB4, plus per-input short-circuit and open-wire detection. Its printed thresholds are the reason to pick it - above 200 mA the input faults solid red, below 0.5 mA it blinks - and it draws 50 mA, which is lighter than any plain input module in the list.
At the 50 mA this module prints, the 1.0 A POINTBus carries 20 modules with nothing left over. A full 63-module rack of this module would be 3150 mA, 3.1 times the 1.0 A budget, so the 63-module figure is a slot count and the current is what decides how many expansion supplies go into the rack.
Two catalog numbers one digit apart often differ in exactly one published figure, and that figure is the one the specification is written around - which is why the ladder is worth reading as a table rather than as a list of options.
What the printed data does not carry: this page prints the sibling descriptions but not their POINTBus currents, so the 50 mA is the only draw in the table that can be used; and no page in this family states a maximum number of modules between two power supplies.
Source: Rockwell publication 1734-IN001 (POINT I/O module and adapter installation instructions) and the module specification tables published on these pages; the class column and the module count are read off the printed lines, not assumed.
The Allen-Bradley POINT I/O 1734 modules category groups the other catalog numbers, options and spare parts in the same range.