Allen Bradley PLC 1734-IA2 / 1734IA2

China Allen Bradley PLC 1734-IA2 / 1734IA2 supplier
Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier Allen Bradley PLC 1734-IA2 / 1734IA2 supplier

Large Image :  Allen Bradley PLC 1734-IA2 / 1734IA2

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-IA2 / 1734IA2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $45.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1734-IA2 technical data PDF download POINT I/O 1734-IA2 / 1734IA2 2-Channel AC Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O AC Input Module

The 1734-IA2 takes 2 nonisolated sinking AC inputs on one slice, 7.5 mA at 120V AC. No external relay or interface card is needed between a 120V or 220V field contact and the POINTBus.

Because the input is sinking and nonisolated, all points share one common and the field supply must come from a source that matches the module voltage class exactly: 65V AC...132V AC.

1734-IA2 2 sinking 120V AC inputs, 65...132V AC, 7.5 mA at 120V IN STOCK
1734-IA4 4 sinking 120V AC inputs, 65...132V AC, 30.9 g IN STOCK
1734-IM2 2 sinking 220V AC inputs, 159...264V AC, 8.5 mA at 220V IN STOCK
1734-IM4 4 sinking 220V AC inputs, 159...264V AC, 30.9 g IN STOCK

Product Specifications 1734-IA2 (PDF)
 Number of inputs
 2 (1 group of 2), nonisolated, sinking
 Voltage, on-state, nom
 120V AC
 Voltage, on-state range
 65V AC...132V AC
 Voltage, off-state, max
 43V AC
 Current, on-state, nom
 7.5 mA @ 120V AC, 60 Hz
 Current, on-state range
 4.0 mA @ 65V AC...8.5 mA @ 132V AC, 60 Hz
 Impedance, input, nom
 10.6 kOhm
 Input filter time
 20 ms hardware filter plus 1...65 ms digital filter, programmable in 1 ms steps
 POINTBus current, max
 75 mA @ 5V DC
 Power dissipation, max
 0.35 W @ 132V AC
 Thermal dissipation, max
 1.19 BTU/hr @ 132V AC
 Isolation voltage
 240V (continuous), type tested at 3250V DC for 60 s, field side to system
 External AC power supply
 120V AC @ 60 Hz, 85...132V AC, 47...63 Hz
 Terminal base
 1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS
 Wiring category
 1 - on signal ports
 Keyswitch position
 8
 Dimensions, HxWxD
 56.0 x 12.0 x 75.5 mm
 Weight, approx
 30.9 g
 Temperature, operating
 -20...55 deg C (-4...131 deg F), T4A

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-SG001E-EN-P (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-IA2 original product photograph, wide view 1734-IA2 original product photograph, label view 1734-IA2 original product photograph, second angle

Voltage window and off-state guard

On-state range 65V AC...132V AC, off-state guaranteed below 43V AC. That gap is what keeps a 120V circuit from reading a stray 40V induced level as a valid ON, and it is the reason this module tolerates long field wiring runs next to contactor coils.

Input current sets the load on the field device

Nominal 7.5 mA @ 120V AC, 60 Hz, with a working range of 4.0 mA @ 65V AC...8.5 mA @ 132V AC, 60 Hz. A dry contact or a small pilot relay has to carry that current reliably at the low end of the range; a sealed reed rated for switching only 1 mA may not wet properly, so check the device's minimum load before dropping a 2-point slice into a panel full of low-current sensors.

Filter: 20 ms hardware plus a digital window

Every Series C AC input slice carries a 20 ms hardware filter, then a digital filter from 1 to 65 ms set in 1 ms steps. Twenty milliseconds is already longer than a half cycle at 60 Hz, so the hardware stage alone rejects most contact bounce; the digital stage is for a noisy bus, not for speed. Do not expect this slice to catch a 10 ms pulse.

Supply, isolation and base

External supply 120V AC @ 60 Hz, 85...132V AC, 47...63 Hz. Isolation is 240V continuous, type tested at 3250V DC for 60 s from field side to system - the highest test level in the POINT I/O digital family, which is what a 220V circuit demands. The slice fits a TB, TBS, TOP or TOPS base at keyswitch position 8 and dissipates 0.35 W @ 132V AC.

Cost per point versus a DC slice

A 2-point AC slice removes four or eight interposing relays, their DIN rail, and the wiring between relay coil and input. On a panel that switches 120V pushbuttons and level switches directly, the saving is real; on a panel already built around 24V DC, stay with a DC slice and keep one voltage class in the cabinet. The four AC input slices share one 30.9 g moulding and one keyswitch position, so keeping a single spare on the shelf covers 2 and 4 point duties in either voltage class.

FAQ — 1734-IA2

What voltage does 1734-IA2 accept?

120V AC nominal, on-state from 65V AC to 132V AC, with off-state guaranteed below 43V AC.

Does it need an external supply?

Yes - 120V AC at 60 Hz, 85...132V AC and 47...63 Hz, wired to the base's field power terminals.

How much current does each point draw?

7.5 mA at 120V AC nominal, ranging from 4.0 mA at 65V AC to 8.5 mA at 132V AC.

Is it isolated?

Nonisolated between the two points, with 240V continuous field-to-system isolation, type tested at 3250V DC for 60 s.

Which base and keyswitch position?

1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS, keyswitch position 8, 75 mA from the 5V POINTBus.


Data sources. Technical values on this page come from Rockwell publication 1734-SG001E-EN-P (POINT I/O Modules Selection Guide) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-IA2: 2-point AC input

1734-IA2 is a 2-point AC input in the POINT I/O family. It mounts on a terminal base assembly that is ordered separately, connects to the POINTBus through the base, and presents its field wiring on the removable terminal block.

AttributeValue
Catalog number1734-IA2
Module type2-point AC input
POINTBus current requirement75 mA
Module width12.1 mm (0.48 in.) standard, 24.1 mm (0.94 in.) for safety modules
Terminal baseOrdered separately: 1734-TB/TBS (8 terminal) or 1734-TB3/TB3S (12 terminal)
Module dimensions77.5 x 12.1 x 56.6 mm (3.05 x 0.48 x 2.23 in.), weight approx. 31-36 g

POINTBus current is the budget that decides how many modules a slice can carry: most digital and analog modules draw 75 mA, the 1734-OW2 draws 80 mA, and 1734-IB4D draws 50 mA. The usable current of the adapter, plus that of any expansion power supply, divided by the per-module draw gives the maximum slice length, and that is a planning calculation rather than a rule of thumb.

Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.

Sink/source and AC-input variants exist because the field device decides the wiring, not the module preference: a sinking input expects the field device to switch to the positive rail, a sourcing input expects it to switch to common, and an isolated AC input exists so that a shared common between channels does not create a path between two different field circuits.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

The system is rated for panel work rather than for a lab bench: modules plug onto bases that are already wired, the RTB stays on the wiring while the electronics come off, and the same base family accepts the next module of the same width. That is the reason a spare part for POINT I/O is usually an RTB or a base rather than a module, and why a maintenance stock built only from modules is incomplete.

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley POINT I/O 1734 modules category.