Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier Allen Bradley PLC 1734-PDN / 1734PDN supplier

Large Image :  Allen Bradley PLC 1734-PDN / 1734PDN

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-PDN / 1734PDN

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $86.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-PDN technical data PDF download POINT I/O 1734-PDN / 1734PDN DeviceNet Interface Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O DeviceNet communication interface

The 1734-PDN is the DeviceNet interface that sits at the left end of a POINT I/O system and supplies the POINTBus. It is not an adapter in the 1734-ADN sense: the PDN has no scanner, no node addressing and no I/O image of its own.

That distinction is the reason it exists. Where the 1734-ADN lets a POINT I/O rack appear as its own DeviceNet node, the PDN makes the rack part of an existing node's I/O - the cheapest way to add POINT I/O to a DeviceNet network that already has a master.

1734-AENT EtherNet/IP adapter, 10/100 Mbit, 63 modules, 1.0 A POINTBus IN STOCK
1734-ADN DeviceNet adapter, 125/250/500 kbit, 63 modules IN STOCK
1734-ADNX DeviceNet adapter with Subnet scanner, node 0 on the subnet IN STOCK
1734-ACNR ControlNet adapter, redundant coax A/B, node 01...99 IN STOCK
1734-APB PROFIBUS DP adapter, 63 modules on one DP node IN STOCK
1734-PDN DeviceNet communication interface, 24V DC 400 mA, 1.3 A POINTBus IN STOCK
1734-EP24DC 24V DC expansion power supply, 1.3 A POINTBus at 19.2...28.8V input IN STOCK
1734-EPAC 120/240V AC expansion power supply, 1.3 A POINTBus, 3250V DC isolation IN STOCK
1734-FPD Field potential distributor, breaks the field power bus, no current draw IN STOCK
1734-ARM Address reserve module, 75 mA POINTBus, keeps a slot addressed IN STOCK

Product Specifications 1734-PDN (PDF)
 DeviceNet communication rate
 125 kbit/s (500 m), 250 kbit/s (250 m), 500 kbit/s (100 m)
 POINTBus output current, max
 1.3 A @ 5V DC +5% (4.75...5.25V)
 I/O module capacity
 Up to 17 modules, 17 x 75 mA = 1.275 A, just under the 1.3 A limit
 DeviceNet power requirements
 24V DC (+4% = 25V DC max) @ 400 mA max
 Input voltage rating
 24V DC nominal, 11...25V DC DeviceNet range
 Inrush current, max
 6 A for 5 ms
 Power consumption
 8.0 W @ 25V DC
 Power dissipation, max
 1.2 W @ 25V DC
 Thermal dissipation, max
 4.1 BTU/hr @ 25V DC
 Isolation voltage
 50V continuous, tested at 2600V DC for 60 s
 Field power bus
 10 A max, 10...28.8V DC or 120/240V AC
 Module location
 Starter module, left side of the 1734 system
 Dimensions, HxWxD
 76.2 x 25.4 x 133.4 mm
 Weight, approx
 0.13 kg
 Wire size
 0.34...2.5 mm2 (22...14 AWG), 75 deg C or greater, 1.2 mm insulation max
 Terminal base screw torque
 0.6 Nm (7 lb-in)

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN057 (module specifications) and 1734-UM016 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-PDN original product photograph 1734-PDN original product photograph, second view 1734-PDN original product photograph, third view

1.3 A is a module count, not a round number

The POINTBus budget is 1.3 A at 5V. Seventeen modules at 75 mA is 1.275 A, which is why Rockwell publishes 17 as the typical count. Fit 1734-IR2 slices at 220 mA and the same budget covers five. Add up the actual current requirement of the slices - the table in 1734-IN057 lists every catalog number at 75, 80, 100, 110, 160, 175, 180 or 220 mA.

Two indicator pairs

System power (green = DC-DC converter active at 5V) and DeviceNet power (green = 24V present on the network). A dark system power LED with a lit DeviceNet LED points at the converter or an overloaded POINTBus, not at the network.

Field power goes through, DeviceNet power does not

The removable terminal block carries 12/24V DC or 120/240V AC field power, which becomes the internal field power bus for the modules to the right. DeviceNet power is separate and must come from a Class 2 source; Rockwell's instruction is explicit that user supplied field power should be kept separate from DeviceNet power. DeviceNet draw is 400 mA at 24V, inrush 6 A for 5 ms.

Where the PDN stops

No 1734-EPAC with the PDN - the AC expansion supply is limited to the adapter class products (ADN, ADNX, APB, ACNR, AENT). For 24V DC expansion the 1734-EP24DC is allowed. The module is the starter module: it goes on the left side of the assembly, and the network goes to the right from there.

FAQ — 1734-PDN

What is the difference between 1734-PDN and 1734-ADN?

The PDN is a communication interface that supplies POINTBus power and has no scanner; the ADN is a DeviceNet adapter that makes the rack its own node.

How many I/O modules can it power?

Up to 17 modules at 75 mA each, because 17 x 75 mA = 1.275 A against a 1.3 A POINTBus limit. Higher current slices reduce the count.

What DeviceNet power does it need?

24V DC at 400 mA maximum from a Class 2 source, with 6 A inrush for 5 ms.

What isolation does it provide?

50V continuous, tested at 2600V DC for 60 s, with 1.2 W dissipation and 8.0 W consumption at 25V DC.

Can 1734-EPAC be used with it?

No. The AC expansion supply is restricted to the 1734 adapters; the 1734-EP24DC is the expansion supply for a PDN system.


Data sources. Technical values on this page come from Rockwell publication 1734-IN057 (POINT I/O DeviceNet Communication Interface Module) and 1734-UM016. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-PDN: compact POINTBus head unit, 25.4 mm width

1734-PDN is a head-of-slice unit in the POINT I/O system. Head units sit to the left of the I/O modules and either own the network connection, supply the POINTBus, or distribute field power; the modules to their right exist only as a slice hanging off that head unit.

AttributeValue
Catalog number1734-PDN
Rolecompact POINTBus head unit, 25.4 mm width
Width56.1 mm (2.21 in.) for the network adapters, 25.4 mm (1.00 in.) for expansion supplies, distributors and the compact head unit
MountingDIN rail, at the head of the slice
System clearance25.4 mm on all sides; 50.8 mm above when safety modules are present
Ordering noteTerminal bases for the I/O modules are separate line items

POINTBus current is the budget that decides how many modules a slice can carry: most digital and analog modules draw 75 mA, the 1734-OW2 draws 80 mA, and 1734-IB4D draws 50 mA. The usable current of the adapter, plus that of any expansion power supply, divided by the per-module draw gives the maximum slice length, and that is a planning calculation rather than a rule of thumb.

Mechanically the system is width-driven: adapters occupy 56.1 mm, expansion power supplies and field power distributors 25.4 mm each, standard I/O modules 12.1 mm each, and safety I/O modules 24.1 mm each. Total panel width is the sum of those, and a layout that assumes a uniform module width is wrong on both the adapter and the safety side.

Clearance is a specification, not a courtesy: 25.4 mm on all sides of the system is the minimum, and a system with POINT I/O safety modules needs 50.8 mm above the assembly. Cabinets that pass at 25 mm on a digital-only slice fail once a safety module is added to the same rail.

The width difference between 56.1 mm and 25.4 mm is the difference between an adapter that carries a network port and a unit that only carries power. Both can head a slice, and both feed the POINTBus, but only the adapter appears on the network as a node; the expansion supply and the field power distributor exist to extend the slice inside the cabinet.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

The Allen-Bradley POINT I/O 1734 modules category lists the related catalog numbers, options and accessories for this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)