The 1734-OV8E is the eight-point protected sinking output for POINT I/O Series C: eight 24V DC channels, 1.0 A each, 3.0 A for the module, a red fault LED per channel and one byte of status data returned to the controller.
The module is non-isolated between channels, so the eight loads share one sinking reference, and its 240V basic isolation to the system side is tested at 2550V DC for 60 s.
| 1734-OV2E | 2 protected sinking outputs, 0.7V DC drop, 2.0 A per module | IN STOCK |
| 1734-OV4E | 4 protected sinking outputs, 0.7V DC drop, 3.0 A per module | IN STOCK |
| 1734-OV8E | 8 protected sinking outputs, 0.7V DC drop, 3.0 A per module | IN STOCK |
Number of outputs |
8 (1 group of 8), non-isolated, sinking |
Output current rating, max per module |
1.0 A per output, not to exceed 3.0 A max per module |
External DC supply current |
32 mA |
On-state voltage, min |
10V DC |
On-state voltage, nominal |
24V DC |
On-state voltage, max |
28.8V DC |
On-state voltage drop, max |
0.7V DC @ 28.8V DC, 55 deg C, full load |
On-state current, min per channel |
1.0 mA |
On-state current, max per channel |
1.0 A (electronically protected) |
Off-state voltage, max |
28.8V DC |
Off-state leakage, max |
0.5 mA |
Output signal delay |
0.1 ms off to on, 0.1 ms on to off |
Surge current |
2 A for 10 ms, repeatable every 3 s |
Data image |
Produces 1 byte of input data (status), consumes 1 byte of output data |
Pilot duty rating |
24V DC 1.0 A |
Keyswitch position |
1 |
Module location |
1734-TB or 1734-TBS wiring base assembly |
POINTBus current, max |
75 mA @ 5V DC |
Isolation voltage |
240V, Basic Insulation Type, tested at 2550V DC for 60 s, output to system |
External DC supply, nominal |
24V DC |
External DC supply range |
10...28.8V DC |
Terminal base screw torque |
0.6 Nm |
Wire size |
0.25...2.5 mm2 (22...14 AWG) solid or stranded copper, 75 deg C or greater |
Dimensions, HxWxD |
56 x 12 x 75.5 mm |
Wire category |
2 - on signal ports |
Temperature code |
T4 (North American) |
Operating temperature |
-20...55 deg C |
Enclosure |
None (open style) |
Power dissipation, max @ 28.8V DC |
2.0 W @ 28.8V DC |
Thermal dissipation, max @ 28.8V DC |
6.8 BTU/hr @ 28.8V DC |
Weight, approx |
35.4 g |
Field wiring terminations |
0...7 - Outputs 0...7, common daisy-chained from the adapter, 1734-FPD or 1734-EP24DC |
Indicators |
8 yellow output status, 8 red output fault, 2 green/red module and network status |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN585D-EN-E (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
All eight channels sink to the same common, which is daisy-chained from a POINT I/O adapter, a 1734-FPD or a 1734-EP24DC, or from a user-supplied terminal block. The 24V DC for the module comes from the same source through the internal power bus and draws 32 mA. If the eight loads need separate references, this is the wrong module - split them across smaller slices.
Each channel protects at 1.0 A and the module is limited to 3.0 A, so eight pilot valves at 0.4 A total 3.2 A and already exceed the limit; the same bank at 0.3 A is fine. The module reports a tripped channel on its red LED and in the status byte, which makes an overloaded bank obvious in commissioning rather than weeks later.
0.7V DC maximum drop at 28.8V DC, 55 deg C and full load means the load sees about 23.3V DC when the supply is at nominal 24V DC. Devices with a narrow pick-up window, or 24V relays specified at 75% pick-up, should be checked against that figure before the module is chosen.
2.0 W, 6.8 BTU/hr at 28.8V DC, the highest of the protected sink family and the same as the sourcing eight-point modules. Add the load heat in the field devices when sizing a sealed enclosure, and remember the drop also generates heat at the module when channels are loaded.
1734-TB or 1734-TBS base only, 0.6 Nm terminal base torque, wire 0.25 to 2.5 mm2 (22 to 14 AWG) copper rated 75 deg C or greater with 1.2 mm maximum insulation. The pilot duty rating is 24V DC 1.0 A, which is the figure a panel builder needs when the load is a contactor or valve pilot rather than a resistive lamp.
What is the difference between a 1734-OV8E and a 1734-OB8E?
The 1734-OV8E is a sinking output: it pulls the load to 0V and the load is tied to the positive supply. The 1734-OB8E is a sourcing output: it switches the positive supply to the load and the load returns to common. Both are protected, both are 1.0 A per channel and 3.0 A per module, and both carry a red fault LED per channel.
Why is the on-state voltage drop of a sink output larger than a source output?
The published figure is 0.7V DC maximum at 28.8V DC, 55 deg C and full load, against 0.2V DC for the sourcing 1734-OB family. The drop is part of the protection circuit, so at 1.0 A the module dissipates roughly 0.7 W in the output stage - check it against a load that is sensitive to receiving 23.3V DC rather than 24V DC.
How many bytes does the module exchange with the scanner?
Two. It produces one byte of input data carrying channel status and consumes one byte of output data carrying the channel commands, which is how the module reports a faulted channel back to the controller.
What is the isolation rating?
240V continuous, Basic Insulation Type, tested at 2550V DC for 60 s from output to system. This is a higher field-side rating than the 50V used on the sourcing 1734-OB and 1734-IB families.
Which terminal base and wire gauge?
1734-TB or 1734-TBS only. Wire is 0.25 to 2.5 mm2 (22 to 14 AWG) solid or stranded copper rated 75 deg C or greater with 1.2 mm maximum insulation, and terminal base screw torque is 0.6 Nm - note this is lower than the 0.8 Nm used on the input and sourcing output modules.
What happens on a short circuit?
The channel is electronically protected and limits current to 1.0 A; the yellow status LED goes out and the red fault LED for that channel comes on. Remove the cause and re-energise the channel. Surge capability is 2 A for 10 ms repeatable every 3 s.
Is a 1734-OV8E a drop-in replacement for a 1734-OV8?
The 1734-OV8 series protected sink modules are catalogued as 1734-OV2E, 1734-OV4E and 1734-OV8E - there is no unprotected 1734-OV8 in this publication. Confirm the existing catalog number before ordering, because the base and wire rules for the E family (1734-TB or 1734-TBS, 0.6 Nm) are narrower than for the sourcing outputs.
The Allen-Bradley POINT I/O 1734 modules category groups the other catalog numbers, options and spare parts in the same range.