logo
Home ProductsAB POINT I/O 1734

Allen Bradley PLC 1734-OV2E / 1734OV2E

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1734-OV2E / 1734OV2E

China Allen Bradley PLC 1734-OV2E / 1734OV2E supplier
Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier Allen Bradley PLC 1734-OV2E / 1734OV2E supplier

Large Image :  Allen Bradley PLC 1734-OV2E / 1734OV2E

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley POINT I/O 1734-OV2E / 1734OV2E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $32.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-OV2E technical data PDF download POINT I/O 1734-OV2E / 1734OV2E 2-Point 24V DC Protected Sink Output

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O Digital Output

The 1734-OV2E is the protected two-point 24V DC sinking output for POINT I/O Series C. Both channels are non-isolated, electronically protected to 1.0 A and limited to 2.0 A for the module, and each has its own red fault indicator beside the yellow status LED.

The published on-state drop is 0.7V DC at 28.8V DC, 55 deg C and full load, which is the number to use when a load is sensitive to the supply it actually receives. Isolation is 240V basic type tested at 2550V DC for 60 s.

1734-OV2E 2 protected sinking outputs, 0.7V DC drop, 2.0 A per module IN STOCK
1734-OV4E 4 protected sinking outputs, 0.7V DC drop, 3.0 A per module IN STOCK
1734-OV8E 8 protected sinking outputs, 0.7V DC drop, 3.0 A per module IN STOCK

Product Specifications 1734-OV2E (PDF)
 Number of outputs
 2 (1 group of 2), non-isolated, sinking
 Output current rating, max per module
 2.0 A
 External DC supply current
 8 mA
 On-state voltage, min
 10V DC
 On-state voltage, nominal
 24V DC
 On-state voltage, max
 28.8V DC
 On-state voltage drop, max
 0.7V DC @ 28.8V DC, 55 deg C, full load
 On-state current, min per channel
 1.0 mA
 On-state current, max per channel
 1.0 A (electronically protected)
 Off-state voltage, max
 28.8V DC
 Off-state leakage, max
 0.5 mA
 Output signal delay
 0.1 ms off to on, 0.1 ms on to off
 Surge current
 2 A for 10 ms, repeatable every 3 s
 Data image
 Produces 1 byte of input data (status), consumes 1 byte of output data
 Pilot duty rating
 24V DC 1.0 A
 Keyswitch position
 1
 Module location
 1734-TB or 1734-TBS wiring base assembly
 POINTBus current, max
 75 mA @ 5V DC
 Isolation voltage
 240V, Basic Insulation Type, tested at 2550V DC for 60 s, output to system
 External DC supply, nominal
 24V DC
 External DC supply range
 10...28.8V DC
 Terminal base screw torque
 0.6 Nm
 Wire size
 0.25...2.5 mm2 (22...14 AWG) solid or stranded copper, 75 deg C or greater
 Dimensions, HxWxD
 56 x 12 x 75.5 mm
 Wire category
 2 - on signal ports
 Temperature code
 T4 (North American)
 Operating temperature
 -20...55 deg C
 Enclosure
 None (open style)
 Power dissipation, max @ 28.8V DC
 0.8 W @ 28.8V DC
 Thermal dissipation, max @ 28.8V DC
 2.7 BTU/hr @ 28.8V DC
 Weight, approx
 32.60 g
 Field wiring terminations
 0/2 - Output 0, 1/3 - Output 1, 4/5 - Common, 6/7 - Supply
 Indicators
 2 yellow output status, 2 red output fault, 2 green/red module and network status

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN585D-EN-E (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-OV2E original product photograph, wide view 1734-OV2E original product photograph, label view 1734-OV2E original product photograph, second unit

Sink or source - what the customer is really choosing

A sinking output connects the load to 0V, so the load sits between the positive supply and the module terminal. That suits devices wired to a common positive rail and to relays whose coil return is switched low. If the panel uses a common-negative convention, the sourcing 1734-OB2E is the equivalent module and the wiring convention decides between them.

Protected output stage and its drop

Protection costs voltage: 0.7V DC maximum drop against 0.2V DC on the sourcing family. At 1.0 A the module dissipates roughly 0.7 W in the output stage, and at 28.8V DC the whole slice is rated 0.8 W, so the thermal budget in a sealed cabinet is set by the load current, not by the quiescent module.

Wiring and field supply

Outputs 0 and 2 are output 0, terminals 1 and 3 are output 1, 4 and 5 are common and 6 and 7 are supply, the same terminal pattern as 1734-OB2. The module draws 8 mA from the external 24V DC supply and the load current passes through that same supply, fed through the internal power bus from the adapter, a 1734-FPD or a 1734-EP24DC.

Diagnostics over the network

Unlike the sourcing family, this module produces one byte of status data back to the scanner in addition to consuming its output byte, so a faulted channel is visible in the controller as well as on the red LED. That combination - local LED plus status bit - is the practical difference when the panel is remote.

Installation details that catch people out

Terminal base screw torque is 0.6 Nm for this family, not the 0.8 Nm used on inputs and sourcing outputs, and the accepted wire is 0.25 to 2.5 mm2 (22 to 14 AWG) copper at 75 deg C or better. Only 1734-TB and 1734-TBS are listed - the TB3 and TOP bases used by other modules do not appear in this publication.

FAQ — 1734-OV2E

What is the difference between a 1734-OV8E and a 1734-OB8E?

The 1734-OV8E is a sinking output: it pulls the load to 0V and the load is tied to the positive supply. The 1734-OB8E is a sourcing output: it switches the positive supply to the load and the load returns to common. Both are protected, both are 1.0 A per channel and 3.0 A per module, and both carry a red fault LED per channel.

Why is the on-state voltage drop of a sink output larger than a source output?

The published figure is 0.7V DC maximum at 28.8V DC, 55 deg C and full load, against 0.2V DC for the sourcing 1734-OB family. The drop is part of the protection circuit, so at 1.0 A the module dissipates roughly 0.7 W in the output stage - check it against a load that is sensitive to receiving 23.3V DC rather than 24V DC.

How many bytes does the module exchange with the scanner?

Two. It produces one byte of input data carrying channel status and consumes one byte of output data carrying the channel commands, which is how the module reports a faulted channel back to the controller.

What is the isolation rating?

240V continuous, Basic Insulation Type, tested at 2550V DC for 60 s from output to system. This is a higher field-side rating than the 50V used on the sourcing 1734-OB and 1734-IB families.

Which terminal base and wire gauge?

1734-TB or 1734-TBS only. Wire is 0.25 to 2.5 mm2 (22 to 14 AWG) solid or stranded copper rated 75 deg C or greater with 1.2 mm maximum insulation, and terminal base screw torque is 0.6 Nm - note this is lower than the 0.8 Nm used on the input and sourcing output modules.

What happens on a short circuit?

The channel is electronically protected and limits current to 1.0 A; the yellow status LED goes out and the red fault LED for that channel comes on. Remove the cause and re-energise the channel. Surge capability is 2 A for 10 ms repeatable every 3 s.


Data sources. Technical values on this page come from Rockwell publication 1734-IN585D-EN-E (POINT I/O Protected Sink Output Modules, catalog numbers 1734-OV2E, 1734-OV4E, 1734-OV8E, 1734-OV8EK, Series C, January 2019) and 1734-UM001 (POINT I/O Digital and Analog Modules User Manual). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

The Allen-Bradley POINT I/O 1734 modules category lists the related catalog numbers, options and accessories for this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)