Allen Bradley PLC 1734-OB2EP / 1734OB2EP

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1734-OB2EP / 1734OB2EP

China Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier
Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier Allen Bradley PLC 1734-OB2EP / 1734OB2EP supplier

Large Image :  Allen Bradley PLC 1734-OB2EP / 1734OB2EP

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-OB2EP / 1734OB2EP

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $38.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-OB2EP technical data PDF download POINT I/O 1734-OB2EP / 1734OB2EP Protected Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O Protected Output Module

The 1734-OB2EP is the two-point sourcing output slice with electronic protection built into each channel: short circuit and overload are limited in the module instead of relying on a downstream fuse.

It carries the same 2 A per point, 4 A per module rating as the standard 1734-OB2, so a panel can swap one for the other without re-rating the load - what changes is how the output behaves when the field wiring is wrong.

1734-OB2E 2 protected sourcing outputs, red fault LED per channel, 2.0 A per module IN STOCK
1734-OB4E 4 protected sourcing outputs, red fault LED per channel, 3.0 A per module IN STOCK
1734-OB8E 8 protected sourcing outputs, red fault LED per channel, 3.0 A per module IN STOCK

Product Specifications 1734-OB2EP (PDF)
 Number of outputs
 2 (1 group of 2), non-isolated, sourcing
 Voltage, on-state, min
 10V DC
 Voltage, on-state, nom
 24V DC
 Voltage, on-state, max
 28.8V DC
 Voltage drop, on-state, max
 0.7V DC at 28.8V DC, 55 deg C, full load
 Current, on-state, min
 1 mA per channel
 Current, on-state, max
 2 A per output, 4 A per module
 Surge current, max
 2 A, electronically protected
 Current, off-state, max
 0.5 mA leakage
 Output signal delay, max
 0.1 ms off to on, 0.1 ms on to off
 POINTBus current, max
 75 mA @ 5V DC
 Power dissipation, max
 3.4 W @ 28.8V DC
 Thermal dissipation, max
 11.6 BTU/hr @ 28.8V DC
 Isolation voltage
 50V (continuous), tested at 1250V AC for 60 s between outputs and POINTBus
 External DC power supply
 10...28.8V DC, 13 mA max at 28.8V DC, no load
 Terminal base
 1734-TB or 1734-TBS, 0.6 Nm screw torque
 Wiring category
 2 - on signal ports
 Data size
 produces 1 byte, consumes 1 byte
 Dimensions, HxWxD
 56.0 x 12.0 x 75.5 mm
 Weight, approx
 32.6 g
 Temperature, operating
 -20...55 deg C (-4...131 deg F)

Same-family catalog numbers: 1734-OB2E, 1734-OB4E, 1734-OB8E. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1734 family.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN586C-EN-P (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-OB2EP original product photograph 1734-OB2EP original product photograph, label view 1734-OB2EP original product photograph, second angle

What protected means here

The output stage limits surge current to 2 A electronically. A shorted valve lead therefore does not take out the slice on the first energisation, and the fault is reported per channel through the two red output-fault indicators on the logic side. That is the practical difference from 1734-OB2, where the load has to be protected externally.

2 A per point, 4 A per module, 0.7V drop

Full load is 2 A on either point but only 4 A across both at once - the module total is the constraint, not the per-point figure. At 28.8V DC and 55 deg C the on-state drop reaches 0.7V DC, so a 24V rail delivers about 23.3V to the load at full current. Size a 24V solenoid coil on that, not on the nominal 24V.

0.1 ms output delay and 1 mA minimum

Off-to-on and on-to-off are both 0.1 ms maximum, which is fast enough for a pneumatic solenoid pilot but not a substitute for a high-speed discrete output slice. The 1 mA on-state minimum is the other end of the specification: a solid-state relay or an LED indicator drawing less than that may not hold the output on.

Where the heat comes from

3.4 W at 28.8V DC, 11.6 BTU/hr, is the highest dissipation of any two-point output slice in the family, and it is the price of the protection circuitry. In a full 63-module rack that matters: ten of these slices add 34 W of internal heat before any load current is considered, so leave the 25.4 mm air gap the installation instructions call for.

Terminal base, keyswitch and data

1734-TB or 1734-TBS only, at 0.6 Nm terminal torque - the one-piece TOP bases are not listed for this module. Wiring category 2 on the signal ports means 300V-class segregation from the field wiring rather than the 150V class used on category 1 modules. The slice produces 1 byte and consumes 1 byte on the POINTBus.

FAQ — 1734-OB2EP

What does the EP suffix mean on 1734-OB2EP?

Protected: each output is electronically limited against short circuit and overload, with 2 A surge current limitation and per-channel red fault indicators.

How much current can each output carry?

2 A per output, 4 A per module total, at 10...28.8V DC with a maximum 0.7V DC drop at 28.8V DC and full load.

How fast does the output switch?

0.1 ms maximum off-to-on and 0.1 ms on-to-off. Minimum load current is 1 mA, leakage in the off state is 0.5 mA maximum.

Which base does it need?

1734-TB or 1734-TBS at 0.6 Nm terminal torque. The one-piece TOP bases are not listed for the 1734-OB2EP.

What is its isolation and dissipation?

50V continuous, tested at 1250V AC for 60 s between outputs and POINTBus; 3.4 W and 11.6 BTU/hr at 28.8V DC, with 75 mA from the 5V POINTBus.


Data sources. Technical values on this page come from Rockwell publication 1734-IN586C-EN-P (POINT I/O Protected Output Module, Series C, March 2021) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Where 1734-OB2EP sits in the POINT I/O line

The table reproduces the sibling list this page publishes, with each catalog number put in the class of module it is; the paragraph after it places this part in that ladder, and the arithmetic at the end uses this page's own POINTBus figure against the 1.0 A budget the adapters print.

Catalog numberWhat the published line saysClass of module
1734-OB2E2 protected sourcing outputs, red fault LED per channel, 2.0 A per moduleDigital output
1734-OB4E4 protected sourcing outputs, red fault LED per channel, 3.0 A per moduleDigital output
1734-OB8E8 protected sourcing outputs, red fault LED per channel, 3.0 A per moduleDigital output

1734-OB2EP is the smallest of the three protected sourcing output modules and the only one whose per-output rating is the binding limit: 2 A per output and 4 A per module here, against 3.0 A per module on 1734-OB4E and 1734-OB8E. The red fault LED per channel is printed on all three.

At the 75 mA this module prints, the 1.0 A POINTBus carries 13 modules with nothing left over. A full 63-module rack of this module would be 4725 mA, 4.7 times the 1.0 A budget, so the 63-module figure is a slot count and the current is what decides how many expansion supplies go into the rack.

Read the sibling list by the numbers in the description rather than by the catalog order: channel count, per-channel rating and per-module rating are three separate published figures, and on this page they do not scale together.

What the printed data does not carry: this page prints the sibling descriptions but not their POINTBus currents, so the 75 mA is the only draw in the table that can be used; and no page in this family states a maximum number of modules between two power supplies.

Source: Rockwell publication 1734-IN001 (POINT I/O module and adapter installation instructions) and the module specification tables published on these pages; the class column and the module count are read off the printed lines, not assumed.

Related numbers

The Allen-Bradley POINT I/O 1734 modules category groups the other catalog numbers, options and spare parts in the same range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)