logo
Home ProductsAB POINT I/O 1734

Allen Bradley PLC 1734-TOP3 / 1734TOP3

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1734-TOP3 / 1734TOP3

China Allen Bradley PLC 1734-TOP3 / 1734TOP3 supplier
Allen Bradley PLC 1734-TOP3 / 1734TOP3 supplier Allen Bradley PLC 1734-TOP3 / 1734TOP3 supplier Allen Bradley PLC 1734-TOP3 / 1734TOP3 supplier Allen Bradley PLC 1734-TOP3 / 1734TOP3 supplier Allen Bradley PLC 1734-TOP3 / 1734TOP3 supplier

Large Image :  Allen Bradley PLC 1734-TOP3 / 1734TOP3

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Terminal Base 1734-TOP3 / 1734TOP3

Payment & Shipping Terms:

Minimum Order Quantity: 10 /PCS
Price: $10.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-TOP3 technical data PDF download POINT I/O 1734-TOP3 / 1734TOP3 12-Terminal Wiring Base

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O Terminal Base

The 1734-TOP3 is a 12-terminal POINT I/O wiring base with a screw-clamp removable terminal block: the base mounts on the DIN rail, the I/O module snaps into it, and integrated one-piece block carries the field wiring.

Twelve terminals in a one-piece base: the high density slice footprint without a removable block in the way.

1734-TB 8 terminal wiring base with removable screw-clamp RTB IN STOCK
1734-TB3 12 terminal wiring base with removable screw-clamp RTB3 IN STOCK
1734-TB3S 12 terminal wiring base with removable spring-clamp RTB3S IN STOCK
1734-TOP 8 terminal one-piece base, screw-clamp IN STOCK
1734-TOPS 8 terminal one-piece base, spring-clamp IN STOCK
1734-TOP3 12 terminal one-piece base, screw-clamp IN STOCK
1734-TOP3S 12 terminal one-piece base, spring-clamp IN STOCK
1734-CTM Common terminal module, 2 A per point, 4 A per module IN STOCK

Product Specifications 1734-TOP3 (PDF)
 Number of terminations
 12
 Termination type
 screw-clamp
 Wiring block
 integrated one-piece block
 Field power bus supply voltage
 28.8V DC, 120/240V AC
 Field power bus supply current, max
 10 A
 Signal terminal voltage, max
 28.8V DC, 120/240V AC
 Signal terminal current, max
 2 A
 Wire size
 0.25...2.5 mm2 (22...14 AWG), 75 deg C or greater, 1.2 mm insulation max
 Dimensions, HxWxD
 49 x 12 x 188 mm
 Weight, approx
 79.2 g
 Enclosure type rating
 None (open-style)
 Temperature, operating
 Dependent on the installed module, -20...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN028 (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-TOP3 original product photograph 1734-TOP3 original product photograph, second view 1734-TOP3 original product photograph, third view

Twelve terminals, common and supply repeated

0...3 are channels 0 and 1, 4/5 common, 6/7 supply, 8/9 common again, 10/11 supply again. The layout repeats the common and supply pairs so four channels fit without external jumpers, exactly as on the 1734-TB3.

Screw-clamp on 188 mm of rail

79.2 g and 49 x 12 x 188 mm - 44 mm longer than the 8-terminal TOP. In a 63-module rack that length adds up: 20 high density slices consume an extra 880 mm of rail, which is the argument for counting rail length before specifying density.

Where TOP3 is the right call

Panels that are built once and wired in place, with the same crew, on a rail that has room. If the cabinet will be serviced by someone else, the removable RTB3 on a 1734-TB3 is the safer choice for the same 12 terminals.

Ratings that apply to the whole base

Field power bus 10 A and signal terminals 2 A, at 28.8V DC or 120/240V AC. The 10 A figure is the bus capacity that the 1734-EP24DC and 1734-FPD modules are built around; the 2 A is per signal terminal, which is why an output slice rated 2 A per point uses the base at its limit rather than in the middle of its range. Isolation and voltage segregation come from the module that sits in the base, not from the base itself - the base is a passive wiring carrier.

Removing a base means removing its neighbour first

Rockwell's removal sequence is explicit: remove the module in the base, then the module in the base to the right, then the RTB, then release the orange base locking screw and lift straight up. The base to the right has to come out because the interlocking side pieces and the POINTBus contacts overlap. Pulling a base with power applied interrupts the backplane and can cause unintended machine motion.

FAQ — 1734-TOP3

How many terminals does 1734-TOP3 have?

Twelve: 0...3 channels, 4/5 common, 6/7 supply, 8/9 common, 10/11 supply.

How long is the base on the rail?

49 x 12 x 188 mm, 44 mm longer than the 8-terminal 1734-TOP.

What is the weight?

79.2 g.

Does it need a removable terminal block?

No - it is a one-piece base, so wiring is done on the installed unit.

What are the current ratings?

10 A field power bus, 2 A per signal terminal, 28.8V DC or 120/240V AC.


Data sources. Technical values on this page come from Rockwell publication 1734-IN028 (POINT I/O One-piece Wiring Bases) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-TOP3: terminal base assembly

1734-TOP3 is a POINT I/O terminal base assembly: a DIN-rail mounting base with a 12-terminal RTB, tall base profile. The base is ordered separately from the I/O module because the base and the RTB are the parts that carry the wiring, and the module is the part that is replaced on failure.

AttributeValue
Catalog number1734-TOP3
Assembly type12-terminal RTB, tall base profile
Replacement RTB1734-RTB3
Dimensions, H x W x D167.6 x 13.8 x 79.1 mm (6.60 x 0.54 x 3.11 in.)
Weight79.10 g (2.79 oz)
RTB functionAll field terminations, removable without disturbing wiring
Terminal numberingMarked on the bottom of the RTB
Related base1734-TBCJC adds cold junction compensation for 1734-IT2I

Terminal count decides the base, not the module width: the eight-terminal bases suit modules with one termination per channel, and the twelve-terminal bases are needed where the module presents commons or shield returns in addition to the channel terminals. A two-point analog module needs a shield ground terminal point, which is why the analog side of the family runs on the wider bases.

The terminal base assembly is the part that makes POINT I/O modular: the base mounts on the DIN rail, the removable terminal block (RTB) carries every field termination, and the I/O module plugs onto both. The RTB is ordered with the base as one unit, and a spare RTB is a field-replaceable part rather than a whole new base.

Each terminal point is numbered on the bottom of the RTB, which is why a wiring fault can be traced from the drawing to a numbered terminal instead of to a wire colour. Once the RTB is wired, the block separates from the base and the module without disturbing the terminations, so a module swap does not require re-terminating a single field wire.

Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

Producer/consumer behaviour is what makes the slice worth wiring this way: input data and output status can be shared among several Logix controllers without a second physical input module per controller, so the I/O count is set by field devices rather than by the number of controllers that need to see them.

Browse the Allen-Bradley POINT I/O 1734 modules category for the other models, options and spare parts that share this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)