logo
Home ProductsAB POINT I/O 1734

Allen Bradley PLC 1734-ARM / 1734ARM

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1734-ARM / 1734ARM

China Allen Bradley PLC 1734-ARM / 1734ARM supplier
Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier Allen Bradley PLC 1734-ARM / 1734ARM supplier

Large Image :  Allen Bradley PLC 1734-ARM / 1734ARM

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-ARM / 1734ARM

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $18.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 25 PCS
Detailed Product Description

1734-ARM technical data PDF download POINT I/O 1734-ARM / 1734ARM Address Reserve Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O address reserve module

The 1734-ARM keeps a slot alive. When a POINT I/O module is pulled for repair and the machine has to keep running on the remaining slices, the ARM goes into that base and holds the address, so the controller's I/O image does not renumber.

That is the whole function: 75 mA of POINTBus current and a physical placeholder that tells the adapter the slot is still there and intentionally empty.

1734-AENT EtherNet/IP adapter, 10/100 Mbit, 63 modules, 1.0 A POINTBus IN STOCK
1734-ADN DeviceNet adapter, 125/250/500 kbit, 63 modules IN STOCK
1734-ADNX DeviceNet adapter with Subnet scanner, node 0 on the subnet IN STOCK
1734-ACNR ControlNet adapter, redundant coax A/B, node 01...99 IN STOCK
1734-APB PROFIBUS DP adapter, 63 modules on one DP node IN STOCK
1734-PDN DeviceNet communication interface, 24V DC 400 mA, 1.3 A POINTBus IN STOCK
1734-EP24DC 24V DC expansion power supply, 1.3 A POINTBus at 19.2...28.8V input IN STOCK
1734-EPAC 120/240V AC expansion power supply, 1.3 A POINTBus, 3250V DC isolation IN STOCK
1734-FPD Field potential distributor, breaks the field power bus, no current draw IN STOCK
1734-ARM Address reserve module, 75 mA POINTBus, keeps a slot addressed IN STOCK

Product Specifications 1734-ARM (PDF)
 Function
 Reserves an I/O slot address when a module is removed
 Module location
 1734-TB, TBS, TOP or TOPS wiring base assembly
 POINTBus current, max
 75 mA @ 5V DC
 Power dissipation, max
 0.375 W @ 5V DC
 Thermal dissipation, max
 1.3 BTU/hr @ 5V DC
 Status indicators
 1 green/red network status, 1 green/red module status, logic side
 Keyswitch position
 Use the keyswitch position of the removed module
 Field wiring terminals
 0 = no connection, 3 = protective earth ground, 4 = L2/N
 Dimensions, HxWxD
 56.6 x 12.1 x 77.5 mm
 Weight, approx
 23.3 g

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN019 (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-ARM original product photograph 1734-ARM original product photograph, second view 1734-ARM original product photograph, third view

Address preservation, not I/O simulation

The ARM carries a network status and a module status indicator and nothing else - terminal 0 is explicitly no connection, 3 is protective earth ground and 4 is L2/N. It does not emulate the removed module's data; it keeps the slot from collapsing and shifting every module to its right down by one address.

Keyswitch follows the removed module

Rockwell's instruction is to use the keyswitch position of the module that was removed. The mechanical keying on the base is what stops a wrong slice being fitted later, so matching the ARM to that position keeps the base's keying meaningful when the real module goes back in.

75 mA is real load

75 mA at 5V DC, 0.375 W dissipation, 1.3 BTU/hr. Small, but it counts against the 1.3 A POINTBus budget like any other slice - four ARMs in a rack is 300 mA of the budget spent on placeholders.

56.6 x 12.1 x 77.5 mm, 23.3 g

The same housing as an I/O module, so it occupies one slot and one base. Use it in a 1734-TB, TBS, TOP or TOPS base; the base stays wired and no field wiring is touched.

FAQ — 1734-ARM

What is the 1734-ARM used for?

It reserves the I/O slot address when a module is removed, so the modules to the right keep their addresses in the controller's I/O image.

How much POINTBus current does it draw?

75 mA at 5V DC, with 0.375 W dissipation and 1.3 BTU/hr thermal dissipation.

Which keyswitch position should it use?

The keyswitch position of the module that was removed, so the base keying stays valid when the module is refitted.

What terminals does it have?

Terminal 0 is no connection, 3 is protective earth ground and 4 is L2/N; no I/O signal terminals are used.

What are its dimensions and weight?

56.6 x 12.1 x 77.5 mm and 23.3 g, the same housing as an I/O slice.


Data sources. Technical values on this page come from Rockwell publication 1734-IN019 (POINT I/O Address Reserve Module) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-ARM: POINT I/O mounting and wiring accessory

1734-ARM is a POINT I/O mounting and wiring accessory in the POINT I/O family. It mounts on a terminal base assembly that is ordered separately, connects to the POINTBus through the base, and presents its field wiring on the removable terminal block.

AttributeValue
Catalog number1734-ARM
Module typePOINT I/O mounting and wiring accessory
POINTBus current requirementsee module it serves
Module width12.1 mm (0.48 in.) standard, 24.1 mm (0.94 in.) for safety modules
Terminal baseOrdered separately: 1734-TB/TBS (8 terminal) or 1734-TB3/TB3S (12 terminal)
Module dimensions77.5 x 12.1 x 56.6 mm (3.05 x 0.48 x 2.23 in.), weight approx. 31-36 g

POINTBus current is the budget that decides how many modules a slice can carry: most digital and analog modules draw 75 mA, the 1734-OW2 draws 80 mA, and 1734-IB4D draws 50 mA. The usable current of the adapter, plus that of any expansion power supply, divided by the per-module draw gives the maximum slice length, and that is a planning calculation rather than a rule of thumb.

Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.

Sink/source and AC-input variants exist because the field device decides the wiring, not the module preference: a sinking input expects the field device to switch to the positive rail, a sourcing input expects it to switch to common, and an isolated AC input exists so that a shared common between channels does not create a path between two different field circuits.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

The system is rated for panel work rather than for a lab bench: modules plug onto bases that are already wired, the RTB stays on the wiring while the electronics come off, and the same base family accepts the next module of the same width. That is the reason a spare part for POINT I/O is usually an RTB or a base rather than a module, and why a maintenance stock built only from modules is incomplete.

This part sits in the Allen-Bradley POINT I/O 1734 modules category, with the other models and spare parts listed alongside it.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)