Product Details:
Payment & Shipping Terms:
|
The 1734-ADNX is a DeviceNet adapter that also acts as a scanner: on the plant network it is one slave node, and on its own Subnet it is the master at node 0, so a single DeviceNet connection can reach POINT I/O modules in the assembly plus additional DeviceNet devices on a separate trunk.
The practical difference from 1734-ADN is that the ADNX talks to modules that are not on the backplane at all - remote DeviceNet nodes on a Subnet trunk, addressed above the number of modules plugged into the assembly.
| 1734-AENT | EtherNet/IP adapter, 10/100 Mbit, 63 modules, 1.0 A POINTBus | IN STOCK |
| 1734-ADN | DeviceNet adapter, 125/250/500 kbit, 63 modules | IN STOCK |
| 1734-ADNX | DeviceNet adapter with Subnet scanner, node 0 on the subnet | IN STOCK |
| 1734-ACNR | ControlNet adapter, redundant coax A/B, node 01...99 | IN STOCK |
| 1734-APB | PROFIBUS DP adapter, 63 modules on one DP node | IN STOCK |
DeviceNet communication rate |
125 kbit/s (500 m max), 250 kbit/s (250 m max), 500 kbit/s (100 m max) |
Subnet role |
Scanner and master to the Subnet, node 0 on that network |
Subnet baud rate default |
125 kbit/s (1734-ADN default is 1 Mbaud on the backplane) |
Subnet capacity |
Backplane modules plus non-backplane DeviceNet modules on the Subnet trunk |
Subnet non-backplane addressing |
Node addresses must be numerically greater than the number of backplane modules |
Subnet termination |
Terminating resistor at each end of the trunk, supplied with the adapter |
Node address |
00...63 on the thumbwheel, 64...99 selects the stored address |
DeviceNet current |
30 mA |
Module location |
Starter module, left side of the POINT I/O system |
Module capacity |
63 powered modules, up to 504 I/O points |
POINTBus current |
1000 mA @ 5V DC (4.75...5.25V) |
Field power bus |
24V DC nominal, 10...28.8V DC, 10 A max |
24V current load for the adapter |
400 mA |
Input byte capacity |
248 bytes |
Output byte capacity |
248 bytes |
Isolation voltage |
50V continuous, tested 800V DC for 60 s |
Power consumption |
8.1 W @ 28.8V DC |
Power dissipation, max |
2.8 W @ 28.8V DC |
Thermal dissipation, max |
9.5 BTU/hr @ 28.8V DC |
Terminal base screw torque |
0.5...0.6 Nm (5...7 lb-in) |
Wire size |
0.25...2.5 mm2 (22...14 AWG) copper rated 75 °C or greater, 1.2 mm insulation max |
Temperature code |
T4A (North American), T4 (UKEX/ATEX and IECEx) |
Dimensions, HxWxD |
79.8 x 56.3 x 133.1 mm |
Weight, approx |
260 g |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN026 (module specifications) and 1734-UM002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
On the primary network the adapter receives the connections a DeviceNet master opens and returns the assembly's data; on the Subnet it originates the I/O connections to its own modules as well as to non-backplane devices. That makes the ADNX a two-network device in one panel slot, which is the reason to choose it over an ADN plus a separate scanner.
A terminating resistor must sit at each end of the Subnet trunk segment - the adapter ships with one. If no cable is fitted to the Subnet connector, two resistors are required across CAN_H and CAN_L. Skipping termination produces intermittent I/O that looks like a faulty module.
Non-backplane Subnet modules must have node addresses numerically greater than the number of modules on the ADNX backplane. With eight modules in the assembly, the first remote device can be node 9 and nodes 1 to 8 are not available to it. Plan the Subnet address map before the panel is wired.
The 1734-ADN backplane default is 1 Mbaud; the ADNX Subnet default is 125 kbit/s. Mixing the two assumptions is the most common commissioning failure - set the Subnet baud rate explicitly, and confirm every module shares it before going online.
63 backplane modules, 1000 mA at 5V DC on POINTBus, field power 10...28.8V DC at 10 A, 8.1 W consumption and 2.8 W dissipation, 50V isolation tested at 800V DC for 60 s, 260 g, 79.8 x 56.3 x 133.1 mm. The Subnet capability does not change the power budget.
What is the difference between 1734-ADN and 1734-ADNX?
ADNX also acts as a scanner on its own DeviceNet Subnet, at node 0, so it can reach remote DeviceNet devices in addition to the modules on its backplane. ADN only serves the backplane modules as a slave on the primary network.
How do I address modules on the Subnet?
Non-backplane modules must use node addresses numerically greater than the number of backplane modules - with eight backplane modules, start remote devices at node 9.
What baud rate does the Subnet use by default?
125 kbit/s, unlike the 1734-ADN backplane default of 1 Mbaud. Set it explicitly and make sure every module matches.
Does the Subnet need termination?
Yes - a terminating resistor at each end of the trunk, one of which is supplied with the adapter. With no cable fitted, two resistors belong across CAN_H and CAN_L.
What is the module capacity?
63 backplane modules and 504 I/O points within 1000 mA at 5V DC, plus non-backplane DeviceNet devices on the Subnet trunk.
The table reproduces the sibling list this page publishes, with each catalog number put in the class of module it is; the paragraph after it places this part in that ladder, and the arithmetic at the end uses this page's own POINTBus figure against the 1.0 A budget the adapters print.
| Catalog number | What the published line says | Class of module |
| 1734-AENT | EtherNet/IP adapter, 10/100 Mbit, 63 modules, 1.0 A POINTBus | Network adapter |
| 1734-ADN | DeviceNet adapter, 125/250/500 kbit, 63 modules | Network adapter |
| 1734-ADNX | DeviceNet adapter with Subnet scanner, node 0 on the subnet | Network adapter |
| 1734-ACNR | ControlNet adapter, redundant coax A/B, node 01...99 | Network adapter |
| 1734-APB | PROFIBUS DP adapter, 63 modules on one DP node | Network adapter |
1734-ADNX is the DeviceNet adapter that also scans a Subnet, and it is node 0 on that network. Read the list by network rather than by order: the other four adapters put one network on the backplane, this one puts two, and the printed addressing rule - subnet node numbers must be numerically greater than the number of backplane modules - exists because of that.
The budget the adapters themselves publish is 1.0 A of 5 V POINTBus and 63 modules. Those two limits do not meet: 63 modules at the lightest draw in this whole product line - 50 mA on the diagnostic input module - is 3,150 mA, which is 3.15 times the 1.0 A, so a full rack cannot be powered from one adapter at any module class. That is why the family carries expansion power supplies and why the 63-module figure is a slot count rather than a current plan.
Two catalog numbers one digit apart often differ in exactly one published figure, and that figure is the one the specification is written around - which is why the ladder is worth reading as a table rather than as a list of options.
What the printed data does not carry: no adapter page in this list states its own current draw on the POINTBus, and none prints a maximum backplane length or a cable type for the expansion link. The 1.0 A is an output rating, not a budget that already accounts for the adapter.
Source: Rockwell publication 1734-IN001 (POINT I/O module and adapter installation instructions) and the module specification tables published on these pages; the class column and the module count are read off the printed lines, not assumed.
The Allen-Bradley POINT I/O 1734 modules category groups the other catalog numbers, options and spare parts in the same range.