Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier Allen Bradley PLC 1734-TB3 / 1734TB3 supplier

Large Image :  Allen Bradley PLC 1734-TB3 / 1734TB3

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Terminal Base 1734-TB3 / 1734TB3

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $69.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-TB3 technical data PDF download POINT I/O 1734-TB3 / 1734TB3 12-Terminal Wiring Base

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O Terminal Base

The 1734-TB3 is a 12-terminal POINT I/O wiring base with a screw-clamp removable terminal block: the base mounts on the DIN rail, the I/O module snaps into it, and 1734-RTB3 carries the field wiring.

The 12-terminal base is what makes a 36-point slice possible: four extra terminals and 27 mm of extra rail per module, in exchange for double the field capacity.

1734-TB 8 terminal wiring base with removable screw-clamp RTB IN STOCK
1734-TB3 12 terminal wiring base with removable screw-clamp RTB3 IN STOCK
1734-TB3S 12 terminal wiring base with removable spring-clamp RTB3S IN STOCK
1734-TOP 8 terminal one-piece base, screw-clamp IN STOCK
1734-TOPS 8 terminal one-piece base, spring-clamp IN STOCK
1734-TOP3 12 terminal one-piece base, screw-clamp IN STOCK
1734-TOP3S 12 terminal one-piece base, spring-clamp IN STOCK
1734-CTM Common terminal module, 2 A per point, 4 A per module IN STOCK

Product Specifications 1734-TB3 (PDF)
 Number of terminations
 12
 Termination type
 screw-clamp
 Wiring block
 1734-RTB3
 Field power bus supply voltage
 28.8V DC, 120/240V AC
 Field power bus supply current, max
 10 A
 Signal terminal voltage, max
 28.8V DC, 120/240V AC
 Signal terminal current, max
 2 A
 Wire size
 0.25...2.5 mm2 (22...14 AWG), 75 deg C or greater, 1.2 mm insulation max
 Dimensions, HxWxD
 65 x 12 x 160 mm
 Weight, approx
 97.5 g
 Enclosure type rating
 None (open-style)
 Temperature, operating
 Dependent on the installed module, -20...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN013 (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-TB3 original product photograph 1734-TB3 original product photograph, second view 1734-TB3 original product photograph, third view

Twelve terminals with two internally shorted pairs

Terminals 4, 5, 8 and 9 are internally shorted to each other, and 6, 7, 10 and 11 are internally shorted. That is what lets one base feed four channels: the commons are commoned inside the part, not with a jumper on the terminals. Wiring to two of them and leaving the others unconnected is correct, not a mistake.

Isolation 250V, tested at 1000V AC

250V basic insulation, type tested at 1000V AC for 60 s, field side to system. Field power bus 28.8V DC or 120/240V AC at 10 A; signal terminals 28.8V DC or 120/240V AC at 2 A. That combination is what separates TB3 from TB: the eight-terminal base has no published isolation rating because it was designed around 240V AC field bus only.

0.8 Nm on the RTB3 only

The torque call-out applies to the screw-clamp RTB3. Spring-clamp RTB3S needs none. Wire range is 0.25...2.5 mm2 (24...14 AWG) single wire, or two 0.75 mm2 wires into one terminal, with 14 mm strip length.

Ratings that apply to the whole base

Field power bus 10 A and signal terminals 2 A, at 28.8V DC or 120/240V AC. The 10 A figure is the bus capacity that the 1734-EP24DC and 1734-FPD modules are built around; the 2 A is per signal terminal, which is why an output slice rated 2 A per point uses the base at its limit rather than in the middle of its range. Isolation and voltage segregation come from the module that sits in the base, not from the base itself - the base is a passive wiring carrier.

Removing a base means removing its neighbour first

Rockwell's removal sequence is explicit: remove the module in the base, then the module in the base to the right, then the RTB, then release the orange base locking screw and lift straight up. The base to the right has to come out because the interlocking side pieces and the POINTBus contacts overlap. Pulling a base with power applied interrupts the backplane and can cause unintended machine motion.

FAQ — 1734-TB3

Why does 1734-TB3 have 12 terminals?

To carry four channels plus common and supply pairs: terminals 4/5/8/9 are internally shorted, and so are 6/7/10/11.

What isolation does the base provide?

250V basic insulation, type tested at 1000V AC for 60 s, field side to system.

Can two wires go into one terminal?

Yes - two 0.75 mm2 (18 AWG) wires, with a 16 mm strip length rather than the 14 mm used for a single wire.

Which modules require 1734-TB3?

High density slices such as the eight-point analog and 36-point digital modules that need more than eight field terminals.

What is the rail length per module?

65 x 12 x 160 mm, about 27 mm longer than the 8-terminal 1734-TB.


Data sources. Technical values on this page come from Rockwell publication 1734-IN013 (POINT I/O Wiring Base Assembly, 1734-TB3 and 1734-TB3S) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-TB3: terminal base assembly

1734-TB3 is a POINT I/O terminal base assembly: a DIN-rail mounting base with a 12-terminal screw-clamp RTB. The base is ordered separately from the I/O module because the base and the RTB are the parts that carry the wiring, and the module is the part that is replaced on failure.

AttributeValue
Catalog number1734-TB3
Assembly type12-terminal screw-clamp RTB
Replacement RTB1734-RTB3
Dimensions, H x W x D158.0 x 13.8 x 79.8 mm (6.22 x 0.54 x 3.14 in.)
Weight97.52 g (3.44 oz)
RTB functionAll field terminations, removable without disturbing wiring
Terminal numberingMarked on the bottom of the RTB
Related base1734-TBCJC adds cold junction compensation for 1734-IT2I

Terminal count decides the base, not the module width: the eight-terminal bases suit modules with one termination per channel, and the twelve-terminal bases are needed where the module presents commons or shield returns in addition to the channel terminals. A two-point analog module needs a shield ground terminal point, which is why the analog side of the family runs on the wider bases.

The terminal base assembly is the part that makes POINT I/O modular: the base mounts on the DIN rail, the removable terminal block (RTB) carries every field termination, and the I/O module plugs onto both. The RTB is ordered with the base as one unit, and a spare RTB is a field-replaceable part rather than a whole new base.

Each terminal point is numbered on the bottom of the RTB, which is why a wiring fault can be traced from the drawing to a numbered terminal instead of to a wire colour. Once the RTB is wired, the block separates from the base and the module without disturbing the terminations, so a module swap does not require re-terminating a single field wire.

Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

Browse the Allen-Bradley POINT I/O 1734 modules category for the other models, options and spare parts that share this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)