Product Details:
Payment & Shipping Terms:
|
| 1794-ACN | Flex ControlNet Adaptor | IN STOCK |
| 1794-ACN15 | Flex ControlNet Adaptor | IN STOCK |
| 1794-ACN15K | Flex ControlNet Adaptor | IN STOCK |
| 1794-ACNR | Flex ControlNet Adaptor | IN STOCK |
| 1794-ACNR15 | Flex ControlNet Adaptor | IN STOCK |
| 1794-ACNR15XT | 1794-ACNR15XT C | IN STOCK |
| 1794-ADN | Flex DeviceNet Adaptor | IN STOCK |
| 1794-ADNK | Flex DeviceNet Adaptor | IN STOCK |
| 1794-AENT | FLEX EtherNet/IP Adapter | IN STOCK |
| 1794-AENTR | Flex EtherNet/IP Adapter | IN STOCK |
| 1794-AENTRXT | Flex XT EtherNet/IP Adapter | IN STOCK |
| 1794-APB | Flex PROFIBUS DP Adaptor | IN STOCK |
| 1794-APBDPV1 | Flex Adaptor | IN STOCK |
| 1794-ASB | Flex Remote I/O Adaptor | IN STOCK |
| 1794-ASB2 | Flex Remote I/O Adaptor | IN STOCK |
| 1794-ASBLT | Flex Remote I/O Adaptor | IN STOCK |
| 1794-CE1 | Flex Extension Cable | IN STOCK |
| 1794-CE3 | Flex Extension Cable | IN STOCK |
| 1794-CJC2 | Flex I/O Accessories | IN STOCK |
The 1794-ACNR15 connects a FLEX I/O rail to a ControlNet network over two media channels - Comm A and Comm B - so a single cable fault or a single tap failure does not take the I/O rack off the network. It supports up to eight FLEX I/O modules, runs at 5 Mbps, and implements ControlNet protocol v1.25.
Redundancy here is media redundancy, not controller redundancy: both BNC ports carry the same scheduled traffic, and the adapter keeps producing data if one segment goes down. That is the configuration used on lines where a cable is routed through a cell that gets hit, or where the segment crosses a long distance and a connector is the most likely failure point.
The adapter also contains the 24 V to 5 V converter that feeds the FlexBus for the whole rack - 640 mA at 5 V dc available to the modules - so the rack needs one 24 V feed at the adapter, not a supply per slice. Indicators are per channel: I/O status, Comm A and Comm B, each red/green.
|
Application
|
In-Cabinet
|
|
Brand Name
|
PLC Module
|
|
Cat Num
|
1794-ACNR15
|
|
Communication Protocol
|
ControlNet protocol v1.25, 5 Mbps, redundant media (2 BNC ports) |
|
Enclosure
|
None (open-style)
|
|
Mounting
|
Din-rail, Panel
|
|
Power Supply
|
24V DC nominal, 19.2...31.2V DC; inrush 14 A for 2 ms |
|
Special Features
|
Dual media (Comm A / Comm B); FlexBus output 640 mA at 5V DC |
|
Standard
|
CE,CSA,C-TICK,CUL,GOST,KC,MARINE,UL
|
|
Sub Brand
|
Flex I/O
|
|
Temperature Rating
|
-25...55 C (-13...131 F)
|
|
Type
|
ControlNet redundant-media adapter, 8 I/O modules per rack |
|
UNSPSC
|
32151701
|
Input: 24 V dc nominal, 19.2...31.2 V dc range including 5% ac ripple, drawn from an external supply that must be SELV or PELV to satisfy the CE Low Voltage Directive. Inrush is 14 A for 2 ms, which is the number that decides whether a small 24 V supply will trip when the rack is energised - the supply must tolerate that surge for every adapter on it. Power dissipation is 3.4 W at 19.2 V dc, 15.7 BTU/hr.
Isolation: 50 V continuous, basic insulation type, type tested at 860 V ac for 60 s between power and system, power and ControlNet, and ControlNet and system. There is no isolation between the two ControlNet channels - they are two ports on the same physical layer, which is the reason a ground potential difference between the two segments has to be handled in the cabling, not expected to be blocked by the adapter.
Mechanical: 87 x 94 x 92 mm, 220 g, open-style, DIN rail or panel mount. Power terminal torque 0.8 N·m (7 lb·in); power conductors 0.33...3.31 mm² (22...12 AWG) stranded copper rated 75 °C or higher with 1.2 mm maximum insulation. Wiring category 3 on power ports, 2 on communication ports. North American temperature code T4A, IEC T4. Installation instructions are publication 1794-IN128.
We Could Supply Full Range Of PLC Module.
If you find the PLC Module part that you are looking for, pls Skype / Email us for a quote.
The choice inside the FLEX I/O adapter family is usually one of three: 1794-ACN15 for a single ControlNet segment, 1794-ACNR15 when the segment has to survive a cable fault, and 1794-AENTR when the plant standard is EtherNet/IP. All three carry eight modules and provide the same 640 mA FlexBus budget, so the rack itself does not change - only the network, its cabling and the controller's communication path.
A note on the network side: ControlNet at 5 Mbps is deterministic and scheduled, which is why it survives on high-speed transfer of time-critical data. If the surrounding plant is migrating to EtherNet/IP, the AENTR is the forward-looking part; if the existing ControlNet trunk has to keep running while a segment is repaired, ACNR15 is the part that buys that continuity.
Commissioning note: because both ports are live, the rack must be given a unique ControlNet node address before it is connected to a running trunk - a duplicate node address is the most common reason a redundant adapter appears to work on one channel only. Set the address offline, then connect Comm A and Comm B in that order and watch both channel indicators.
All values on this page are from the FLEX I/O Communication Adapters Specifications technical data, publication 1794-TD014.
Same-family catalog numbers: 1794-ACN, 1794-ACN15, 1794-ACN15K, 1794-ACNR. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1794 family.
Other FLEX I/O adapters, terminal bases and slices are listed on our Allen-Bradley FLEX I/O 1794 category page. Stock and lead time: sales@plc-vip.com.