Product Details:
Payment & Shipping Terms:
|
| 1785-ACC5LA | PLC-5 Accessory Kit | IN STOCK |
| 1785-ACC5LB | PLC-5 Accessory Kit | IN STOCK |
| 1785-CHBM | PLC-5 ControlNet Backup Cartridge | IN STOCK |
| 1785-ENET | PLC-5 ETHERNET/IP EXPAN. MOD FOR PLC-5 | IN STOCK |
| 1785-L20B | PLC-5 Processor | IN STOCK |
| 1785-L20E | PLC-5 Ethernet Processor | IN STOCK |
| 1785-L26B | PLC-5 Protected Processor | IN STOCK |
| 1785-L40B | PLC-5 Processor | IN STOCK |
| 1785-L40C | PLC-5 ControlNet 1.25 Processor | IN STOCK |
| 1785-L40C15 | PLC-5 ControlNet 1.5 Processor | IN STOCK |
| 1785-L40E | PLC-5 Ethernet Processor | IN STOCK |
| 1785-L46C15 | PLC-5 ControlNet 1.5 Protected Processor | IN STOCK |
| 1785-L60B | PLC-5 Processor | IN STOCK |
| 1785-L60L | PLC-5 Processor | IN STOCK |
| 1785-L80B | PLC-5 Processor | IN STOCK |
| 1785-L80C | PLC-5 ControlNet 1.25 Processor | IN STOCK |
| 1785-L80C15 | PLC-5 ControlNet 1.5 Processor | IN STOCK |
| 1785-L80E | PLC-5 Ethernet Processor | IN STOCK |
| 1785-L86B | PLC-5 Protected Processor | IN STOCK |
| 1785-M100 | PLC-5 100 K Words Memory Memory Module | IN STOCK |
| 1785-ME16 | PLC-5 16 K Words Memory Memory Module | IN STOCK |
| 1785-ME32 | PLC-5 32 K Words Memory Memory Module | IN STOCK |
| 1785-ME64 | PLC-5 64 K Words Memory Memory Module | IN STOCK |
| 1785-RC | PLC-5 Relay Cartridge | IN STOCK |
The 1785-L20E is the Ethernet version of the PLC-5/20: the same 16K words of user memory and 512 I/O points, the same fixed DH+ channel and configurable DH+/Remote I/O channel, plus a built-in Ethernet port that speaks 802.3/TCP-IP at 10 Mbps. It exists so that a PLC-5 cell can join a plant network without a 1785-ENET side module or a 1785-KA bridge.
The Ethernet port is a 15-pin transceiver (MAU/AUI) connection, not an RJ45 - it attaches to thin-wire or thick-wire Ethernet through an external transceiver. That is the detail that catches people replacing one of these today: the cabling is 10Base2/10Base5 era, so a media converter or a copper transceiver is part of the project, not an accessory.
Everything else is standard PLC-5/20: channel 1A fixed DH+ on a 3-pin connector with address set by SW-1, channel 0 serial configurable for RS-232/423/422A, four rack addresses (0...3), 13 I/O chassis with 12 remote. Programming and monitoring over Ethernet uses the 6200 series software with an Ethernet PCMCIA or PC/AT card and the appropriate transceiver.
| Application | 802.3/TCP-IP Ethernet via 15-pin MAU (AUI) transceiver, 10 Mbps; 4 rack addresses (0-3), 13 chassis |
|
Brand Name
|
PLC Module |
|
Cat Num
|
1785-L20E |
|
Operating Temperature
|
0-60 Degrees C |
|
Standard
|
CE-EMC,CSA,CSA_HAZ,C-TICK,GOST_R,MARINE-ABS,MARINE- BVS,MARINE-DNV,MARINE-GL,MARINE-KRS,MARINE- LR,ROSTECHNADZOR,UL-US
|
|
Sub Brand
|
PLC-5 |
|
Type
|
Ethernet PLC-5 processor (PLC-5/20E): 16K words, 512 I/O, 1 fixed DH+, 1 DH+/RIO, 1 serial, 1 Ethernet channel |
|
UNSPSC
|
32151705 |
Ethernet configuration in the PLC-5 is done through the channel configuration screen, where the controller is given an IP address, a subnet mask and a hardware address, and where the BOOTP/DHCP behaviour is selected - the same file that carries the “defaults5E" client string seen in the manual's examples. Because it is a 10 Mbps interface, throughput is modest by modern standards but entirely adequate for programming, HMI data and inter-controller messaging on a PLC-5-era line.
Power: the PLC-5/20 family draws 2.3 A at 5 V dc from the backplane with 12 W maximum dissipation - the same as the non-Ethernet /20 and /11. The Ethernet circuitry does not add a separate supply; there is no external transceiver power requirement beyond the MAU itself.
Memory: 16K words maximum user memory, expandable with the 1785-ME16/ME32/ME64 nonvolatile modules; 16,384 words of available user memory is the figure to compare against the existing program size. Battery is the 1770-XYC. Communication port isolation is tested at 500 V for 60 s. Operating temperature 0...60 °C, storage -40...85 °C, open-style enclosure, approximately 1.45 kg.
We Could Supply Full Range Of PLC Module.
If you find the PLC Module part that you are looking for, pls Skype / Email us for a quote.
Three things decide whether an L20E drops into an existing cell. One: the network - a 10 Mbps AUI port needs a transceiver, and if the plant has moved to switched 100 Mbps Ethernet, a media converter is required at the panel. Two: the rack budget - four rack addresses and 13 chassis are the same as the /20, so a growing cell still needs a /40 at the point where it exceeds them. Three: the program - 16K words is the ceiling, and an Ethernet-equipped processor is often the one carrying the most messaging logic, so the memory headroom should be measured before the swap rather than after.
Where a PLC-5 needs only to be reachable from a modern network and does not need a native Ethernet port in the processor, the 1785-ENET expansion module on a standard Enhanced PLC-5 achieves the same result - worth comparing on price and lead time before committing to the E variant.
One more field point: the PLC-5/20E keeps the fixed DH+ port because most installed cells still have a DH+ trunk serving remote I/O and older panel devices. Replacing a /20B with a /20E does not remove that trunk - it adds a second path, and the two can be used at the same time, which is how a plant migrates one segment at a time instead of stopping the line for a network cut-over.
Specifications on this page are from publications 1785-UM012 and 1785-IN062.
Same-family catalog numbers: 1785-L20B, 1785-L26B. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1785 family.
PLC-5 processors, 1785-ENET modules and 1771 I/O are listed on our Allen-Bradley PLC-5 Systems category page. Stock and lead time: sales@plc-vip.com.