Product Details:
Payment & Shipping Terms:
|
1761-CBL-PM02 is the cable that connects MicroLogix 1000 controller to a personal computer.
Unlike the controllers and the communication adaptors of the 1761 family, this cable is still on the Rockwell catalogue as Active Mature, with a published lead time. That makes it the one part of a MicroLogix 1000 panel that can still be bought new when a connector goes missing.
| 1761-CBL-PM02 | Cable: MicroLogix 1000 controller to a personal computer | IN STOCK |
| 1761-CBL-AP00 | Cable: MicroLogix 1000 controller to port 1 of the adaptor chain | IN STOCK |
| 1761-CBL-AM00 | Cable: MicroLogix 1000 controller to port 2 of the adaptor chain | IN STOCK |
| 1761-CBL-AS09 | Cable: SLC 5/01, 5/02 and 5/03 RJ45 port to port 3 | IN STOCK |
| 1761-CBL-AS03 | Cable: SLC 5/01, 5/02 and 5/03 RJ45 port to port 3 | IN STOCK |
| 1761-CBL-AC00 | Cable: 9-pin port of a 1761-NET-AIC to a 9-pin port | IN STOCK |
| 1761-CBL-HM02 | Cable: MicroLogix 1000 controller to the hand-held programmer | IN STOCK |
Catalog number |
1761-CBL-PM02 |
Description |
MicroLogix cable: MicroLogix 1000 controller to a personal computer |
Class |
Power cable |
Lifecycle status |
Active Mature |
UPC |
662468368674 |
Estimated lead time |
5 days |
Country of origin |
China |
Warranty |
1 year standard |
Publication |
1761-UM003 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1761-UM003 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Use: MicroLogix 1000 controller to a personal computer.
The MicroLogix 1000 programming port is an 8-pin mini DIN carrying RS-232. The cable is the physical translation between that connector and the 9-pin port on the other end; nothing in the controller changes because of it.
A generic serial cable will plug in and may even transfer data, but the pin assignment on a mini DIN programming port is not the standard 9-pin null-modem map. A wrong cable is the usual reason a controller refuses to go online, and it is also the usual reason a port is damaged when a cable is forced into the socket.
Keep the correct cable with the panel. For a machine that is serviced once a year, a missing cable costs more in downtime than the cable costs to keep.
Cable length is a fixed part of the catalog number and is not chosen at order time. The controller dimensions printed for the family already include a note to add about 13 mm when a 1761-CBL-PM02 or 1761-CBL-HM02 connector is plugged in, which is the clearance needed inside a cabinet door.
Route the cable so the connector is not carrying the weight of the run. The mini DIN shell is small and the strain ends up on the controller socket.
Rockwell lists an estimated lead time of 5 days for this catalog number, with China as the country of origin and a one year standard warranty.
Lead times on these accessories move. A 51 day item is effectively a project part, not a spare, so the panel that depends on it should carry one on the shelf.
The cable is the cheapest item in the MicroLogix 1000 spares list and the one most often lost. Alongside a controller spare and a communication adaptor, it is what lets an engineer get online without waiting for a delivery.
Because the part is still active, a cable bought today is a current production item rather than new old stock of unknown storage history.
What does 1761-CBL-PM02 connect?
MicroLogix 1000 controller to a personal computer.
Is 1761-CBL-PM02 still available from Rockwell?
Yes. It is listed as Active Mature, with an estimated lead time of 5 days.
Where is 1761-CBL-PM02 made?
China, per the Rockwell product page.
Does 1761-CBL-PM02 have a UPC?
662468368674 on the Rockwell product page.
Can a standard serial cable replace 1761-CBL-PM02?
No. The programming port uses an 8-pin mini DIN with a non-standard pin map; a generic cable is the usual cause of a controller that will not go online.
1761-CBL-PM02 is the programming cable, mini-DIN to D-shell, 2 m in the MicroLogix 1000 accessory family. The controller itself is the packaged unit with supply, inputs, outputs and processor in one housing; everything in this family is what connects to it, powers a network segment from it, or carries its program away from it.
| Attribute | Value |
| Catalog number | 1761-CBL-PM02 |
| Product type | programming cable, mini-DIN to D-shell, 2 m |
| Family | MicroLogix 1000 accessories, bulletin 1761 |
| Length | 2 m (6.5 ft) |
| Ends | 8-pin mini-DIN to DB-9 D-shell, DTE wiring |
| Typical uses | Computer serial port or SLC 5/03, 5/04, 5/05 channel 0 to the AIC+ or ENI port 2 |
| Also listed for | MicroLogix 1500 LRP channel 1, CompactLogix, FlexLogix and ControlLogix serial ports |
| Hazardous area | Series C or later for Class I Division 2 installations |
| Mechanical effect | Fitted connector adds approximately 13 mm (0.51 in) to the controller depth |
| Replacement | 1747-CP3 is the 3 m cable of the same electrical type for SLC channel 0 |
The 2 m length is the one that matters in a panel: it reaches from a laptop on the floor to a controller mounted at the bottom of a cabinet without pulling the connector sideways. Where the run has to leave the enclosure, the D-shell end is the side that goes to the computer, and the mini-DIN end stays on the controller or converter.
Class I Division 2 installations restrict which cable may be used, and the restriction is stated per catalog number with a series letter: the programming cables have to be series C or later to be used in a hazardous environment. A general purpose cable of the same length is not the same part for that location.
Any converter that is not connected to a controller needs its own 24V dc supply, and the AIC+ is the one that can be powered through the communication cable when it sits on a controller port 2. Miswiring a supply into that port causes permanent damage, which is why the published instruction is 24V dc only, never a 120V or 230V source.
MicroLogix 1000 controllers store the program in 1K EEPROM, approximately 737 instruction words and 437 data words, and keep 24V dc user supply at 200 mA maximum. Any accessory that appears to add controller memory has to be read carefully, because the 1761-HHM modules belong to the hand held programmer and do not enlarge the controller.
Converter supplies are not interchangeable in the paperwork: the AIC+ is rated 20.4 to 28.8V dc with 104 to 120 mA draw and 200 mA inrush, the ENI 20.4 to 26.4V dc with 50 mA typical and 100 mA maximum, and the DNI takes 11 to 25V dc from the DeviceNet connector with 200 mA at 24V dc. A 24V dc supply shared across all three has to be sized on the inrush, not on the steady state.
The family is discontinued in stages, and the documentation follows: the DNI manual has been withdrawn from the literature site while the AIC+ and ENI manuals are still published. When a catalog number is quoted against an obsolete network, read the manual revision before promising compatibility with a current controller series.
Before ordering, confirm the catalog number against the port it has to reach, confirm the series letter where the installation is in a classified area, and confirm the supply budget of the panel against the current the device draws at 24V dc.
The Allen-Bradley MicroLogix 1000 1761 controllers category lists the related catalog numbers, options and accessories for this range.