logo
Home ProductsAB CompactLogix 1769

Allen Bradley PLC 1769-PA4 / 1769PA4

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1769-PA4 / 1769PA4

China Allen Bradley PLC 1769-PA4 / 1769PA4 supplier
Allen Bradley PLC 1769-PA4 / 1769PA4 supplier Allen Bradley PLC 1769-PA4 / 1769PA4 supplier Allen Bradley PLC 1769-PA4 / 1769PA4 supplier Allen Bradley PLC 1769-PA4 / 1769PA4 supplier Allen Bradley PLC 1769-PA4 / 1769PA4 supplier

Large Image :  Allen Bradley PLC 1769-PA4 / 1769PA4

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1769-PA4 / 1769PA4

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $260.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 25 PCS
Detailed Product Description

1769-PA4 technical data PDF download 1769-PA4 / 1769PA4 Compact I/O AC Power Supply 4 A

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Power Supply

The 1769-PA4 is the 4 A AC power supply for a 1769 Compact I/O bank: 85...265V AC input with a 170...265V AC switch-selectable range, 4.0 A at 5V and 2.0 A at 24V, 200VA drawn at 120V AC and 240VA at 240V AC.

It exists for banks that the PA2 cannot carry — a full bank of 32-point or analog modules — and the trade is 18 W of dissipation against the PA2's 8 W, plus a 240V range that has to be selected by switch rather than tracked automatically.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1769-PA4 (PDF)
 Application
 Compact I/O bank power supply
 Cat Num
 1769-PA4
 Brand Name
 Rockwell
 Input voltage range
 85...265V AC, or 170...265V AC switch selectable
 Input voltage, nom
 120V/220V AC
 Power consumption
 200VA @ 120V AC; 240VA @ 240V AC
 Current capacity @ 5V
 4.0 A
 Current capacity @ 24V
 2.0 A
 Power dissipation
 18 W @ 60 °C (140 °F)
 Inrush current, max
 25 A @ 132V AC
 Isolation voltage
 265V continuous, reinforced insulation
 Fuse type
 Wickmann 19193-6.3A; Littelfuse 021706.3MXP
 Weight, approx
 630 g (1.39 lb)
 Dimensions (H * W * D), approx
 118 * 70 * 87 mm

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1769-PA4 Compact I/O AC power supply, factory packaging 1769-PA4 power supply front view with status indicators 1769-PA4 label detail showing catalog number and ratings

Output budget and bank size

4.0 A at 5V, 2.0 A at 24V. Twice the 5V and 2.5 times the 24V capacity of the PA2, which is what a bank of analog outputs or 32-point modules needs. Eight modules per side. The physical limit is unchanged from the PA2; the PA4 buys current, not slot count. 200VA at 120V AC. Size the upstream circuit and any UPS for the input power, not the DC output.

The switch-selectable input range

85...265V AC, or 170...265V AC. The narrow range is selected by switch; a supply left on the wide setting in a 230V system works, but the correct setting is part of commissioning. 6.3 A fuse. Wickmann 19193-6.3A or Littelfuse 021706.3MXP, uprated from the PA2's 3.15 A to match the larger input. 25 A inrush at 132V AC. The same inrush as the PA2, so a panel full of PA4 supplies does not change the breaker coordination study.

Heat, size and enclosure

18 W at 60 °C. More than twice the PA2's figure; in a sealed enclosure this is the supply that forces a thermal calculation. 630 g, 118 * 70 * 87 mm. Same two-module footprint as the PA2, heavier by 105 g — the difference is the transformer and the larger output stage. 0...60 °C, 5...95% RH. The same environmental envelope as every other 1769 supply, with 6 kV contact and 8 kV air ESD immunity.

Where the PA4 is the right answer

Analog-heavy banks. 1769-IF16C and -IF16V draw 190 mA at 5.1V each; eight of them plus digital modules is a PA4 bank, not a PA2 bank. 32-point digital banks. 1769-IQ32 and -OB32 draw 170 mA and similar at 5.1V but their distance rating of 6 modules on the OB32 limits how far the bank can spread. Keep one supply type per panel. Mixing PA2 and PA4 in one enclosure complicates the spares list for no functional gain.

Commissioning checks

Verify the input range switch position before energising — 170...265V AC for a 230V system. Add every module's 5.1V and 24V current and leave headroom for one spare module. Record the 6.3 A fuse in the spares list; it is not the same part as the PA2's 3.15 A. Check the dissipation against the enclosure's thermal budget at 60 °C ambient, the worst case the supply is certified for.

FAQ — 1769-PA4

What is the output of the 1769-PA4?

4.0 A at 5V and 2.0 A at 24V, from an 85...265V AC input, drawing 200VA at 120V AC and 240VA at 240V AC.

What is the difference between 1769-PA2 and 1769-PA4?

Output current and heat: 2.0 A/0.8 A at 8 W for the PA2 against 4.0 A/2.0 A at 18 W for the PA4, in the same 118 * 70 * 87 mm footprint.

Does the 1769-PA4 have a voltage selector?

Yes, the input is 85...265V AC or 170...265V AC switch selectable, so the switch position has to be set for the supply voltage in use.

What fuse does the 1769-PA4 take?

A Wickmann 19193-6.3A, equivalent to Littelfuse 021706.3MXP.

How hot does the 1769-PA4 run?

18 W of dissipation at 60 °C ambient, which is the figure to use in an enclosure thermal calculation.

Can the 1769-PA4 be used on a 24V DC system?

No; the DC input version is the 1769-PB2 (2 A) or the 1769-PB4 (4 A), which also carry the ATEX and IECEx Zone 2 approvals.


Data sources. Technical values on this page come from Rockwell publication 1769-TD008 (CompactLogix Power Supplies Specifications) and 1769-IN028 (Compact I/O Expansion Power Supplies), current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The four 1769 bank supplies

A Compact I/O bank is powered by one of four supplies, and the two numbers that decide the choice are the 5V and 24V capacities - not the input voltage, which only decides whether the panel has AC or DC available. The published rows are below.

CatalogInput range5V capacity24V capacityDissipationInrushWeight
1769-PA285...265V AC2.0 A0.8 A8 W @ 60 °C (140 °F)25 A @ 132V AC525 g (1.16 lb)
1769-PB219.2...31.2V DC2.0 A0.7 A7.5 W @ 60 °C (140 °F)30 A @ 31.2V DC525 g (1.16 lb)
1769-PA485...265V AC, or 170...265V AC switch selectable4.0 A2.0 A18 W @ 60 °C (140 °F)25 A @ 132V AC630 g (1.39 lb)
1769-PB419.2...31.2V DC4.0 A1.7 A14.5 W @ 60 °C (140 °F)30 A @ 31.2V DC630 g (1.39 lb)

The 24V capacity is the figure most often overlooked: it feeds the modules that need field power from the bank rather than from a separate Class 2 supply, and it is smaller than the 5V figure on every one of the four units. A bank with several analog or specialty modules can exhaust the 24V rail while the 5V rail still has room.

Inrush is published per supply and it is what the upstream breaker sees when the panel is energised: the figure is a cold-start current on the AC side, and a panel with several supplies switched together adds them. That is the reason the supply counts against the feeder sizing as well as against the bank budget.

The dissipation figure is the heat that stays inside the enclosure, and it is larger than most engineers assume for a supply this size — it belongs in the cabinet thermal calculation beside the modules, not in the load list alone.

The family table above is shared across the sibling pages; the number this page answers for is 1769-PA4.

Related numbers

The Allen-Bradley CompactLogix 1769 controllers category lists the related catalog numbers, options and accessories for this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)