logo
Home ProductsAB MicroLogix 1000 1761

Allen Bradley PLC 1761-NET-AIC / 1761NETAIC

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1761-NET-AIC / 1761NETAIC

China Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier
Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier Allen Bradley PLC 1761-NET-AIC / 1761NETAIC supplier

Large Image :  Allen Bradley PLC 1761-NET-AIC / 1761NETAIC

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1761-NET-AIC / 1761NETAIC

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $121.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1761-NET-AIC technical data PDF download 1761-NET-AIC Rockwell AIC+ Advanced Interface Converter

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: MicroLogix 1000 / 1761

1761-NET-AIC is the AIC+ Advanced Interface Converter in the 1761 accessory family: Advanced Interface Converter that links DH-485 and RS-232 networks and isolates the two sides.

The adaptors were the way a MicroLogix 1000 or a fixed SLC 500 got onto a plant network before Ethernet was built into the controller. They are discontinued, but a large installed base still runs on them, and a spare is often the fastest way to keep a line talking to a SCADA node.

1761-NET-ENI MicroLogix and SLC Ethernet Adaptor IN STOCK
1761-NET-DNI MicroLogix and SLC DeviceNet Adaptor IN STOCK
1761-NET-AIC AIC+ Advanced Interface Converter IN STOCK
1761-NET-ENIW MicroLogix and SLC Ethernet Adaptor, web-enabled IN STOCK

Product Specifications 1761-NET-AIC (PDF)
 Catalog number
 1761-NET-AIC
 Description
 Advanced Interface Converter that links DH-485 and RS-232 networks and isolates the two sides.
 Class
 Signal converters
 Ports
 9-pin D-shell to DH-485 / RS-232 8-pin mini DIN
 Mounting
 Panel or DIN rail, DIN rail power or 24V dc supply
 Isolation
 Communication side isolated from the controller supply
 Lifecycle status
 Discontinued December 31, 2016
 Replacement category
 No planned RA replacement
 UPC
 662468718998
 Publication
 1761-SG001

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1761-SG001 (MicroLogix 1000 selection guide and specifications). Certification details, with certificate and file numbers, are listed in the FAQ below.

1761-NET-AIC 1761-NET-AIC 1761-NET-AIC 1761-NET-AIC 1761-NET-AIC 1761-NET-AIC

What the adaptor does

Advanced Interface Converter that links DH-485 and RS-232 networks and isolates the two sides.

The converter sits between the controller's RS-232 port and the network. It answers on the network side and polls the controller on the serial side, so the controller's own protocol and program are untouched — no ladder edit, no firmware change, just a node that appears on the network.

Ports and wiring

Ports: 9-pin D-shell to DH-485 / RS-232 8-pin mini DIN. The serial side is an 8-pin mini DIN on the Ethernet adaptors, which is the same connector the MicroLogix 1000 programming port uses, so the cable that reaches the controller is the same class of part.

The unit is a panel or DIN rail device with its own supply. Keep the serial run short — these adaptors were specified for a cable at the controller, not for a long drop through a cabinet.

Isolation and network behaviour

The communication side is transformer-isolated from the controller supply, which is what allows an adaptor on a panel whose logic ground is not the same as the network ground. That isolation is the reason the part survives on machines where a bare serial-to-Ethernet bridge would not.

Throughput is bounded by the serial link, not by the network. An adaptor does not make a 1761-L32BWA into a fast Ethernet controller; it makes it reachable. Plan polling rates accordingly, especially where several clients read the same controller.

Commissioning and spares

Commissioning needs the adaptor's own configuration utility and the network parameters: IP address, subnet and, on the DeviceNet members, a node address and baud rate. Record those settings in the panel documentation — a replacement adaptor is useless without them, and the settings live in the adaptor, not in the controller.

A failed adaptor does not stop the machine. The controller keeps scanning its I/O and the local panel keeps working; only the network side goes dark. That makes a spare the cheapest fix, and it is why these parts are still traded.

Lifecycle and replacement

1761-NET-AIC was discontinued on December 31, 2016, with No planned RA replacement as the replacement category.

For a new installation the answer is a controller with Ethernet on board rather than an adaptor on an RS-232 port. For an existing panel the answer is usually a tested spare or a planned migration of the whole node.

FAQ — 1761-NET-AIC

What does 1761-NET-AIC connect?

Advanced Interface Converter that links DH-485 and RS-232 networks and isolates the two sides.

Which controllers does 1761-NET-AIC work with?

MicroLogix 1000, 1200 and 1500 controllers and fixed SLC 500 processors with an RS-232 port, per the adaptor's own user manual.

What ports does 1761-NET-AIC provide?

9-pin D-shell to DH-485 / RS-232 8-pin mini DIN.

Is 1761-NET-AIC still available from Rockwell?

No. Discontinued on December 31, 2016; replacement category No planned RA replacement.

Does 1761-NET-AIC need a separate power supply?

Yes, the adaptor is a panel or DIN rail device with its own supply.


Data sources. Port descriptions and class come from the Rockwell product page of the catalog number; network behaviour and commissioning practice follow the user manual for the adaptor family. Discontinued dates and replacement categories are from the Rockwell product page. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1761-NET-AIC: advanced interface converter, AIC+

1761-NET-AIC is the advanced interface converter, AIC+ in the MicroLogix 1000 accessory family. The controller itself is the packaged unit with supply, inputs, outputs and processor in one housing; everything in this family is what connects to it, powers a network segment from it, or carries its program away from it.

AttributeValue
Catalog number1761-NET-AIC
Product typeadvanced interface converter, AIC+
FamilyMicroLogix 1000 accessories, bulletin 1761
Product typeThree port converter for DH-485, DF1 and user networks
Port 1RS-232, DB-9 DTE
Port 2RS-232, 8-pin mini-DIN
Port 3RS-485, Phoenix plug
Supply24V dc, 20.4 to 28.8V dc
Current draw104 mA at 24V dc per the MicroLogix 1000 manual, 120 mA with 200 mA inrush per the AIC+ installation chapter
Isolation500V dc internal
Network limits32 nodes maximum, 1219 m (4000 ft) per multidrop network, 2 ganged networks maximum
Not compatibleThe 1761-HHP-B30 programmer cannot be connected to the converter

Each node on a DH-485 network needs its own converter, which is the cost item that catches out a first network design: three controllers plus a programming terminal is four converters, not one. The converter carries 32 nodes and 1219 m per segment and allows two ganged segments, so a plant that grows past that needs a second converter pair rather than a longer cable run.

Any converter that is not connected to a controller needs its own 24V dc supply, and the AIC+ is the one that can be powered through the communication cable when it sits on a controller port 2. Miswiring a supply into that port causes permanent damage, which is why the published instruction is 24V dc only, never a 120V or 230V source.

MicroLogix 1000 controllers store the program in 1K EEPROM, approximately 737 instruction words and 437 data words, and keep 24V dc user supply at 200 mA maximum. Any accessory that appears to add controller memory has to be read carefully, because the 1761-HHM modules belong to the hand held programmer and do not enlarge the controller.

Class I Division 2 installations restrict which cable may be used, and the restriction is stated per catalog number with a series letter: the programming cables have to be series C or later to be used in a hazardous environment. A general purpose cable of the same length is not the same part for that location.

The family is discontinued in stages, and the documentation follows: the DNI manual has been withdrawn from the literature site while the AIC+ and ENI manuals are still published. When a catalog number is quoted against an obsolete network, read the manual revision before promising compatibility with a current controller series.

The 8-pin mini-DIN port is the common thread through the whole accessory family: the programmer, the AIC+ port 2, the ENI port 2 and the DNI port 2 all speak through it, and the difference between the cables is only the far end and the length. A 45 cm cable is an inside the panel part, a 2 m cable is a reach across the floor, and a D-shell end is what goes to a computer or an SLC channel 0.

Before ordering, confirm the catalog number against the port it has to reach, confirm the series letter where the installation is in a classified area, and confirm the supply budget of the panel against the current the device draws at 24V dc.

The Allen-Bradley MicroLogix 1000 1761 controllers category lists the related catalog numbers, options and accessories for this range.