logo
Home ProductsAB CompactLogix 1769

Allen Bradley PLC 1769-IF8 / 1769IF8

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1769-IF8 / 1769IF8

China Allen Bradley PLC 1769-IF8 / 1769IF8 supplier
Allen Bradley PLC 1769-IF8 / 1769IF8 supplier Allen Bradley PLC 1769-IF8 / 1769IF8 supplier Allen Bradley PLC 1769-IF8 / 1769IF8 supplier Allen Bradley PLC 1769-IF8 / 1769IF8 supplier Allen Bradley PLC 1769-IF8 / 1769IF8 supplier Allen Bradley PLC 1769-IF8 / 1769IF8 supplier

Large Image :  Allen Bradley PLC 1769-IF8 / 1769IF8

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1769-IF8 / 1769IF8

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $448.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1769-IF8 technical data PDF download CompactLogix 1769-IF8 / 1769IF8 8-Channel Analog Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1769-IF8 (also written 1769IF8) is the 8-channel analog input module of the Compact I/O 1769 range: eight channels, each configurable as differential or single-ended, accepting ±10V, 0…10V, 0…5V, 1…5V, 0…20 mA or 4…20 mA. Conversion is Delta Sigma with 16-bit unipolar or 15-bit-plus-sign bipolar resolution.

The channel-to-channel architecture is the reason this module exists next to the 1769-IF4: twice the channels in the same one-slot footprint, at 120 mA from the 5.1V bus and 70 mA from the 24V field supply, with 3.24 W maximum heat. Both current draw figures matter — the 5.1V part is charged to the bank supply budget, the 24V part to the external Class 2 supply used for current loops.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1769-IF8 (PDF)
 Application
 Compact I/O, 1769 bus
 Cat Num
 1769-IF8
 Brand Name
 Rockwell
 Inputs
 8, differential or single-ended
 Input range
 ±10V, 0…10V, 0…5V, 1…5V, 0…20 mA, 4…20 mA
 Full-scale range
 ±10.5V; −0.5…10.5V; −0.5…5.25V; 0.5…5.25V; 0…21 mA; 3.2…21 mA
 Current draw @ 5.1V
 120 mA
 Current draw @ 24V
 70 mA
 Heat dissipation, max
 3.24 W
 Converter type
 Delta Sigma
 Resolution
 16 bits unipolar; 15 bits plus sign bipolar
 Rated working voltage
 30V AC / 30V DC
 Common mode voltage
 ±10V DC max per channel
 Input impedance
 Voltage 220 kΩ; current 250 Ω
 Accuracy @ 25 °C
 Voltage ±0.2% full-scale; current ±0.35% full-scale
 Module location
 DIN rail or panel mount

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1769-IF8 Compact I/O 8-channel analog input module, factory packaging 1769-IF8 module, front view with terminal block 1769-IF8 label detail showing catalog number

Where the module sits in a CompactLogix system

Signal types in one module. Voltage and current channels share the module: transmitters on 4…20 mA and ±10V drives or load cells on voltage can sit side by side, each channel configured in the module's own configuration rather than by jumpers. Differential or single-ended. Differential wiring is the choice for low-level signals and for loops where the transmitter ground is not the panel ground; single-ended halves the terminals used but gives up common-mode rejection. The published common-mode limit is ±10V DC per channel — a transmitter floating 20V above panel ground is outside the module's rating even before accuracy is considered. Bus and field supply. The module takes 120 mA from the 5.1V backplane bus and up to 70 mA from the 24V field supply for current loops. The 24V side must be a Class 2 source in the 20.4…26.4V DC range; Series B and later modules support that external supply option. One slot. 35 mm wide, 118 * 35 * 87 mm, DIN rail or panel mount, with the printed power-supply distance rating of eight modules per bank.

Accuracy, resolution and what they mean on site

Resolution versus accuracy. 16-bit resolution does not mean 16-bit accuracy: the published accuracy at 25 °C is ±0.2% of full scale on voltage and ±0.35% on current. On a 4…20 mA loop a 0.35% full-scale error is roughly ±0.06 mA — enough to matter in a batching or dosing loop and irrelevant in a tank level display. Full-scale range. The module reads beyond the nominal range: ±10.5V for a ±10V channel, 3.2…21 mA for a 4…20 mA channel. That over-range is what lets the controller detect an over-current or an open circuit instead of clipping silently. Input impedance. 250 Ω on current inputs and 220 kΩ on voltage inputs. The 250 Ω loop burden is part of the loop's total resistance and has to be subtracted when a transmitter specifies its maximum load. Working voltage. Rated 30V AC / 30V DC with ±10V common-mode per channel. A 120V AC conductor near the analog pair is a wiring error, not something the module absorbs.

Commissioning in four checks

Set the channel configuration — range, differential or single-ended, and the filter — in Studio 5000 before download; a channel left at default range reads a valid number that means nothing. Verify the 24V field supply is Class 2 and within 20.4…26.4V DC at the module terminals under load, not at the supply terminals with no load. Check terminal torque at 0.68 N·m (6 lb·in), retaining screw torque at 0.46 N·m (4.1 lb·in), and use 22…14 AWG solid copper rated 90 °C. Inject a known signal at the field terminals — a 4 mA and a 20 mA point on a current channel, 0V and 10V on a voltage channel — and record the raw counts. That record is the baseline for every later drift complaint.

Substituting or replacing a 1769-IF8

1769-IF4 — four channels, same ranges and Delta Sigma conversion, 14-bit resolution, 120 mA at 5.1V and 60 mA at 24V, 2.52 W. Use it where four channels are enough and the extra resolution of the IF8 is not required. 1769-IF16C — sixteen single-ended current-only channels, 190 mA at 5.1V, 70 mA at 24V, 4.0 W — the right choice for a cabinet of 4…20 mA transmitters. 1769-IF16V — the voltage counterpart for sixteen single-ended voltage channels. 1769-IF4I — isolated analog input, for channels that cannot share a common reference.

Which Compact I/O analog input to specify

1769-IF4 — 4 channels, 14-bit, 2.52 W, smallest analog slice draw. 1769-IF8 — 8 channels, 16-bit unipolar, 3.24 W, mixed voltage and current on one slice. 1769-IF16C / IF16V — 16 single-ended channels, current-only or voltage-only, 4.0 W. 1769-IR6 — six RTD / resistance channels for temperature, not a process-signal module. 1769-IT6 — six thermocouple channels for temperature, likewise a different measurement class. Decide by signal count, by whether voltage and current must coexist, and by whether isolation is needed; then confirm the 5.1V and 24V draw against the bank supply and the Class 2 field supply.

FAQ — 1769-IF8

How many channels does 1769-IF8 have and how are they wired?

Eight, each selectable as differential or single-ended. Differential uses two terminals per channel and rejects common-mode voltage up to ±10V DC per channel; single-ended uses one terminal per channel against a common reference, halving terminal count at the cost of that rejection.

What analog ranges does 1769-IF8 accept?

±10V, 0…10V, 0…5V, 1…5V, 0…20 mA and 4…20 mA, with full-scale range extending to ±10.5V, −0.5…10.5V, −0.5…5.25V, 0.5…5.25V, 0…21 mA and 3.2…21 mA so over-range is measurable rather than clipped.

What is the accuracy of 1769-IF8?

±0.2% of full scale at 25 °C on voltage and ±0.35% on current, per 1769-TD006. Resolution is 16 bits unipolar and 15 bits plus sign bipolar — the accuracy figure is the one to quote to a client.

How much current does 1769-IF8 draw?

120 mA from the 5.1V backplane bus and 70 mA from the 24V field supply, with 3.24 W maximum heat dissipation. The 24V draw only applies when the external Class 2 supply option is used for current loops.

Can 1769-IF8 replace a 1769-IF4 one for one?

Mechanically yes — both are one slot, 118 * 35 * 87 mm, on the same 1769 bus — but the tag layout and channel count change, so the Studio 5000 project must be re-configured and the 5.1V budget re-checked: 120 mA for both, with the 24V side rising from 60 mA on the IF4 to 70 mA on the IF8.

Does 1769-IF8 provide channel-to-channel isolation?

No. Isolation is group to bus, rated 500V AC or 710V DC for one minute with 30V AC / 30V DC working voltage; channels share a reference. Where isolation is required, use 1769-IF4I or separate modules.

What wire size and torque does 1769-IF8 use?

22…14 AWG solid copper rated 90 °C, terminals at 0.68 N·m (6 lb·in), retaining screws at 0.46 N·m (4.1 lb·in).


Data sources. Technical values on 1769-IF8 come from Rockwell publication 1769-TD006 (1769 Compact I/O Modules Specifications) and 1769-SG001 (CompactLogix and Compact GuardLogix Systems Selection Guide), both current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

Related models, options and spare parts for this range are listed in the Allen-Bradley CompactLogix 1769 controllers category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)