logo
Home ProductsAB CompactLogix 1769

Allen Bradley PLC 1769-IA8I / 1769IA8I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1769-IA8I / 1769IA8I

China Allen Bradley PLC 1769-IA8I / 1769IA8I supplier
Allen Bradley PLC 1769-IA8I / 1769IA8I supplier Allen Bradley PLC 1769-IA8I / 1769IA8I supplier Allen Bradley PLC 1769-IA8I / 1769IA8I supplier Allen Bradley PLC 1769-IA8I / 1769IA8I supplier Allen Bradley PLC 1769-IA8I / 1769IA8I supplier Allen Bradley PLC 1769-IA8I / 1769IA8I supplier Allen Bradley PLC 1769-IA8I / 1769IA8I supplier

Large Image :  Allen Bradley PLC 1769-IA8I / 1769IA8I

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1769-IA8I / 1769IA8I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $152.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1769-IA8I technical data PDF download CompactLogix 1769-IA8I / 1769IA8I 8-Point Isolated 120V AC Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1769-IA8I (also written 1769IA8I) is the eight-point 120V AC input with point-by-point isolation — the only AC input in the 1769 family that lets each channel sit on a different source. Where the sixteen-point 1769-IA16 forces all points onto one internally connected common, this module isolates every input against the bus and against the other groups.

That isolation is what makes it the right choice in a mixed panel: one point reading a 120V AC feed from the machine section, another reading a feed from a separate control transformer, a third reading a contact from a different enclosure. It costs twice the module per point and an extra 45 mA of 5.1V current against the IA16, and it buys the wiring freedom.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1769-IA8I (PDF)
 Application
 Compact I/O, 1769 bus
 Cat Num
 1769-IA8I
 Brand Name
 Rockwell
 Inputs
 8, individually isolated
 Voltage category
 100/120V AC
 Operating voltage range
 79…132V AC, 47…63 Hz
 Input delay, on / off
 20 ms / 20 ms
 Current draw @ 5.1V
 90 mA
 Heat dissipation, max
 1.81 W
 Off-state voltage / current
 20V AC max / 2.5 mA max
 On-state voltage / current
 79V AC min / 5 mA @ 74V AC min, 12 mA @ 120V AC max
 Inrush current, max
 250 mA
 Input impedance, max
 12 kΩ @ 50 Hz; 10 kΩ @ 60 Hz
 Isolation
 1517V AC 1 s or 2145V DC 1 s, point to bus and group to group; 132V AC working voltage
 Slot width / weight
 1 slot / 270 g
 Power supply distance
 8 modules

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1769-IA8I Compact I/O 8-point isolated 120V AC input module, factory packaging 1769-IA8I module, front view with terminal block 1769-IA8I label detail showing catalog number

Where the module sits in a CompactLogix system

Bank and supply. 90 mA at 5.1V, 1.81 W, one slot, eight-module distance rating; powered from the bank's 1769-PA2 / PB2 / PA4 / PB4. Eight isolated points. The published isolation is 1517V AC for 1 s (or 2145V DC) from input point to bus and group to group, with a 132V AC working voltage — the reason separate AC feeds can be terminated on one slice. Same electrical behaviour as the IA16. 79…132V AC at 47…63 Hz, 20 ms on and 20 ms off, 12 kΩ at 50 Hz and 10 kΩ at 60 Hz. What differs is only the isolation and the point count.

Input behaviour that decides field wiring

Leakage versus minimum current. Off-state current may reach 2.5 mA per point while the minimum on-state current is 5 mA at 74V AC. Neon pilots and long cable runs leak into that band and hold a point on. Inrush and the resistor trade. 250 mA inrush; a 6.8 kΩ (2.5 W minimum) series resistor cuts it to 35 mA but raises the minimum on-state voltage to 92V AC. In a hazardous area the resistor's own surface temperature has to stay inside the enclosure rating — the specification says so explicitly. Twenty milliseconds is fixed. Long enough to reject contact bounce on a selector switch, short enough for a normal scan; it will not catch a pulse shorter than 20 ms.

Commissioning in four checks

Label which AC source each point is wired to — the module allows several, and the drawing must record it, because a later swap to 1769-IA16 would short those feeds together. Measure each source at the terminals under load and confirm 79…132V AC; a sagging feed drops points individually here, not as a bank. Torque terminals at 0.68 N·m (6 lb·in), retaining screws at 0.46 N·m (4.1 lb·in), 22…14 AWG solid or 22…16 AWG stranded copper rated 90 °C. Verify every point against a known pilot device before closing the panel; with isolated inputs a cross-feed shows up as a single stuck point.

Substituting or replacing a 1769-IA8I

1769-IA16 — sixteen points on one internally connected common, 115 mA, 3.30 W; cheaper per point but all points must share one AC source. 1769-IM12 — twelve points at 200/240V AC on one common, for 230V control circuits. 1769-IQ16 — sixteen 24V DC sink/source inputs when the field circuit can be converted to DC. There is no 16-point isolated 120V AC module in the family; above eight isolated points the answer is two 1769-IA8I modules.

Which Compact I/O AC input to specify

1769-IA8I — 8 points, 120V AC, individually isolated, 90 mA. 1769-IA16 — 16 points, 120V AC, one internal common, 115 mA. 1769-IM12 — 12 points, 240V AC, one internal common, 100 mA. Choose isolation when the panel genuinely has more than one AC control source; otherwise the IA16 costs less current and less panel width per point.

FAQ — 1769-IA8I

What does the “I" in 1769-IA8I mean?

Individually isolated: each of the eight 120V AC inputs is isolated from the bus and from the other inputs, rated 1517V AC for 1 s with a 132V AC working voltage. It is the only isolated AC input in the 1769 range.

How many inputs does 1769-IA8I have?

Eight, and they do not share a common — that is the whole point of the catalog number against the sixteen-point 1769-IA16.

What AC voltage range does 1769-IA8I accept?

79…132V AC at 47…63 Hz, rated 100/120V AC, with a fixed 20 ms on and 20 ms off delay.

What does 1769-IA8I draw from the backplane?

90 mA at 5.1V with 1.81 W maximum heat dissipation, one slot, 270 g, eight-module power-supply distance rating.

Can inrush current on 1769-IA8I be reduced?

Yes, with a 6.8 kΩ (2.5 W minimum) series resistor: inrush falls to 35 mA but the minimum on-state voltage rises to 92V AC. The resistor's surface temperature must also stay within the enclosure's rating.

Why does a 1769-IA8I point stay on with the switch open?

Off-state current can reach 2.5 mA per point against a 5 mA minimum on-state current at 74V AC. A neon indicator or leakage path near that limit holds the point on.


Data sources. Technical values on 1769-IA8I come from Rockwell publication 1769-TD006 (1769 Compact I/O Modules Specifications) and 1769-SG001 (CompactLogix and Compact GuardLogix Systems Selection Guide), both current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley CompactLogix 1769 controllers category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)