Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1769-PA2 / 1769PA2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $158.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 25 PCS
Detailed Product Description

1769-PA2 technical data PDF download 1769-PA2 / 1769PA2 Compact I/O AC Power Supply

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Power Supply

The 1769-PA2 is the 2 A AC power supply for a 1769 Compact I/O bank: 85...265V AC input at 47...63 Hz, 2.0 A at 5V and 0.8 A at 24V out, 100VA drawn at 120V AC and 130VA at 240V AC.

A bank that hangs off an expansion cable needs its own supply — a 1769-CLLx, -CRRx or -CRLx cable carries bus communication, not power. The PA2 is the entry-level choice for that second or third bank, and 8 W of dissipation at 60 °C is the number that decides whether it can sit in a closed enclosure without a fan.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1769-PA2 (PDF)
 Application
 Compact I/O bank power supply
 Cat Num
 1769-PA2
 Brand Name
 Rockwell
 Input voltage range
 85...265V AC
 Input voltage, nom
 120V/220V AC
 Power consumption
 100VA @ 120V AC; 130VA @ 240V AC
 Current capacity @ 5V
 2.0 A
 Current capacity @ 24V
 0.8 A
 Power dissipation
 8 W @ 60 °C (140 °F)
 Inrush current, max
 25 A @ 132V AC
 Isolation voltage
 265V continuous, reinforced insulation
 Fuse type
 Wickmann 19195-3.15A; Littelfuse 02183.15MXP
 Weight, approx
 525 g (1.16 lb)
 Dimensions (H * W * D), approx
 118 * 70 * 87 mm

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1769-PA2 Compact I/O AC power supply, factory packaging 1769-PA2 power supply front view with status indicators 1769-PA2 label detail showing catalog number and ratings

What the PA2 supplies

2.0 A at 5V, 0.8 A at 24V. That is the complete output budget; sum the module current draws on both rails against it before adding another module. As many as eight modules per side. 1769 modules may sit to the left and to the right of the supply, eight on each side, so a single PA2 covers a 16-module bank subject to the current budget and to each module's own distance rating. 100VA at 120V, 130VA at 240V. The input power figure is what the panel's upstream circuit has to carry, not the 5V and 24V output.

Input, fuse and isolation

85...265V AC wide range. One catalog number covers 120V and 230V nominal systems without a selector switch, unlike the PA4. Fuse. A Wickmann 19195-3.15A (Littelfuse 02183.15MXP) protects the input; it is a replaceable item and belongs in the spares kit. 265V reinforced isolation. AC input to system and AC input to the 24V user supply, routine tested at 2596V DC for 1 s, with IEC Class 1 grounding required.

Heat and enclosure planning

8 W at 60 °C. The lowest dissipation in the 1769 family — half the PA4's 18 W — so the PA2 tolerates the tighter enclosure. 0...60 °C ambient. Certified only inside that surrounding-air range; the same 5...95% non-condensing humidity, 5 g vibration and 6 kV contact / 8 kV air ESD immunity as the modules it feeds. 118 * 70 * 87 mm, 525 g. Two module widths of panel space, which matters when the bank is being laid out on a 35 mm DIN rail.

Choosing between PA2, PA4, PB2 and PB4

PA2 vs PA4. Same 85...265V AC input, four times the 24V current and twice the 5V current on the PA4 (4.0 A at 5V, 2.0 A at 24V), at 18 W of dissipation and 630 g. AC vs DC. PA2 and PA4 take mains; PB2 and PB4 take 19.2...31.2V DC and are the Zone 2 variants with ATEX and IECEx approval. Count the modules first, then the current. Eight modules per side is a physical limit, but the 5V sum usually binds earlier on banks built from analog or 32-point modules.

Commissioning and spares

Check the 5V and 24V totals against 2.0 A and 0.8 A with the bank fully populated, not at the drawing stage. Confirm every module sits within its distance rating from this supply, not from the controller. Keep one 3.15 A fuse per supply in the panel spares; a blown input fuse is the first thing to check when a bank is dead but the controller is alive. A 1769-L3x controller needs its own supply as well — the controller is not a substitute for the bank supply.

FAQ — 1769-PA2

What is the output of the 1769-PA2?

2.0 A at 5V and 0.8 A at 24V, from an 85...265V AC input drawing 100VA at 120V AC and 130VA at 240V AC.

How many modules can one 1769-PA2 power?

As many as eight 1769 modules on each side of the supply, subject to the 5V and 24V current budget and to each module's power supply distance rating.

How much heat does the 1769-PA2 dissipate?

8 W at 60 °C, the lowest in the 1769 power supply range; the PA4 dissipates 18 W, the PB2 7.5 W and the PB4 14.5 W.

What fuse does the 1769-PA2 use?

A Wickmann 19195-3.15A, equivalent to Littelfuse 02183.15MXP, on the AC input.

Can the 1769-PA2 feed a second I/O bank?

Yes. Each additional bank needs its own supply because the expansion cable carries only bus communication, and two cables give a maximum of three banks.

Is the 1769-PA2 approved for hazardous locations?

It carries UL Class I Division 2 listing; the ATEX and IECEx Zone 2 approvals belong to the 1769-PB2 and 1769-PB4 DC variants.


Data sources. Technical values on this page come from Rockwell publication 1769-TD008 (CompactLogix Power Supplies Specifications) and 1769-IN028 (Compact I/O Expansion Power Supplies), current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley CompactLogix 1769 controllers category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)