logo
Home ProductsAB MicroLogix 1200 1762

Allen Bradley PLC 1762-OB32T / 1762OB32T

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1762-OB32T / 1762OB32T

China Allen Bradley PLC 1762-OB32T / 1762OB32T supplier
Allen Bradley PLC 1762-OB32T / 1762OB32T supplier Allen Bradley PLC 1762-OB32T / 1762OB32T supplier Allen Bradley PLC 1762-OB32T / 1762OB32T supplier Allen Bradley PLC 1762-OB32T / 1762OB32T supplier Allen Bradley PLC 1762-OB32T / 1762OB32T supplier Allen Bradley PLC 1762-OB32T / 1762OB32T supplier

Large Image :  Allen Bradley PLC 1762-OB32T / 1762OB32T

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1762-OB32T / 1762OB32T

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $205.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1762-OB32T technical data PDF download 1762-OB32T Rockwell MicroLogix 1200 expansion module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: MicroLogix 1200 / 1762

1762-OB32T is a 1762 expansion module for the MicroLogix 1200 and 1500: 32 point 24v dc source output module.

Expansion modules clip onto the controller bus and appear as extra I/O in the same data files, with no special programming. A 1200 brick carries up to six of them, and the platform is still orderable — most 1762 I/O is listed Active Mature rather than discontinued, which is unusual for a controller family this old.

1762-IQ8OW8 8 Point 24V DC Input / Relay Output Module IN STOCK
1762-IR4 4 Channel RTD / Resistance Input Module IN STOCK
1762-OW8 8 Point VAC/VDC Relay Output Module IN STOCK
1762-OA8 8 Point 120/240V AC Output Module IN STOCK
1762-OB8 8 Point 24V DC Source Output Module IN STOCK
1762-OB32T 32 Point 24V DC Source Output Module IN STOCK
1762-IQ32T 32 Point 24V DC Sink/Source Input Module IN STOCK
1762-IF4 4 Channel Current/Voltage Analog Input Module IN STOCK
1762-IQ8 8 Point 24V DC Sink/Source Input Module IN STOCK
1762-IA8 8 Point 120V AC Input Module IN STOCK
1762-OX6I 6 Point 24V DC Isolated High Current Relay Output Module IN STOCK
1762-OV32T 32 Point 24V DC Sink Output Module IN STOCK
1762-OB16 16 Point 24V DC Source Output Module IN STOCK
1762-OF4 4 Channel Analog Output Module IN STOCK
1762-IT4 4 Channel Thermocouple/mV Input Module IN STOCK

Product Specifications 1762-OB32T (PDF)
 Catalog number
 1762-OB32T
 Description
 32 Point 24V DC Source Output Module
 Channels
 32 sourcing dc outputs
 Class
 Expansion I/O module, MicroLogix 1200 / 1500 system
 Bus power
 +5V dc and +24V dc from the system power supply
 Dimensions
 90 mm high (110 mm with mounting tabs), 87 mm deep, 40 mm wide
 Shipping weight
 260 g with carton
 Heat dissipation
 3.4 W
 Power supply distance
 6 modules maximum from the supply
 Operating temperature
 0…55 °C
 Storage temperature
 -40…85 °C
 Humidity
 5…95 %, non-condensing
 Vibration
 10…500 Hz, 5 g
 Shock
 30 g operating
 Lifecycle status
 Active Mature
 UPC
 612598849925
 Estimated lead time
 5 days
 Publication
 1762-UM003

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1762-UM003 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1762-OB32T 1762-OB32T 1762-OB32T 1762-OB32T 1762-OB32T

What the module adds

32 sourcing dc outputs on the 32 point 24v dc source output module.

The module is a bus device: it takes +5V dc and +24V dc from the controller supply, reports into the controller's input and output image, and is configured from the programming software rather than by switches. Analog modules are calibrated in software, not with potentiometers.

Bus loading and placement

Every module draws from the same 5V and 24V budget. Heat dissipation for this module is 3.4 W, which is the number to add to the controller figure when the enclosure is sized.

Power supply distance rating is six: a module may not sit more than six modules away from the system power supply. In a full six-module line that is automatically satisfied; in a longer line built on a 1500 system the placement has to be checked.

Current draw is published per module in the manual and has to be summed before the module count is frozen. Adding a seventh relay output module to a panel that is already at its 24V limit is the usual way an expansion goes wrong.

Wiring and environment

Dimensions are 90 mm high, 110 mm including mounting tabs, 87 mm deep and 40 mm wide, at 260 g shipping weight. Two M4 or #8 screws per module is the panel method; DIN rail works but panel mounting is preferred where vibration is present.

Operating temperature is 0…55 °C, storage -40…85 °C, humidity 5…95 % non-condensing, vibration 5 g over 10…500 Hz, shock 30 g. The module is UL 508 listed, C-UL certified and CE compliant, and rated Class I Division 2 for hazardous locations when installed per the manual.

Commissioning an analog module

Analog inputs and outputs are configured per channel: input range, filter frequency and data format. The default configuration is not necessarily the range the sensor uses, so a module that reads zero is often simply configured for the wrong range rather than faulty.

RTD and thermocouple modules need the sensor type set per channel as well. Recording the channel configuration in the panel documentation saves the next engineer a trip.

Availability

Lifecycle status on the Rockwell product page: Active Mature, with a published lead time of 5 days where the page lists one. That makes 1762 I/O a live spare line even though the controllers it plugs into are discontinued.

For a new machine the same functions exist in the Micro800 expansion range, but the modules are not interchangeable — different bus, different terminal base.

FAQ — 1762-OB32T

What does 1762-OB32T provide?

32 Point 24V DC Source Output Module.

Which controllers accept 1762-OB32T?

MicroLogix 1200 and MicroLogix 1500 systems.

Is 1762-OB32T still available from Rockwell?

Lifecycle status: Active Mature.

How much heat does 1762-OB32T add?

3.4 W.

How far from the power supply can 1762-OB32T sit?

Six modules maximum, the published distance rating.


Data sources. Channel description and lifecycle come from the Rockwell product page of the catalog number; heat dissipation is taken from the module table in 1762-UM001, temperature, humidity, vibration, shock, dimensions and weight from the expansion module specification in 1762-UM003. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The fifteen 1762 expansion modules ranked by printed heat

The table lines up all fifteen thin 1762 expansion modules on the one number each of their pages prints that can be compared directly - heat dissipation in watts - together with the capacity and point count printed in the same field table.

Catalog numberCapacity as printedPoints or channelsPrinted heatHeat per point
1762-IQ32T32 dc inputs325.4 W0.169 W
1762-IQ8OW84 dc inputs and 4 relay outputs84.4 W0.55 W
1762-IQ88 dc inputs83.7 W0.46 W
1762-OB32T32 sourcing dc outputs323.4 W0.106 W
1762-OV32T32 sinking dc outputs323.4 W0.106 W
1762-OA88 triac outputs82.9 W0.36 W
1762-OB1616 sourcing dc outputs162.9 W0.181 W
1762-OW88 relay outputs82.9 W0.36 W
1762-OX6I6 isolated relay outputs62.8 W0.47 W
1762-IA88 ac inputs82 W0.25 W
1762-IF44 analog input channels42 W0.50 W
1762-OF44 analog output channels42 W0.50 W
1762-OB88 sourcing dc outputs81.6 W0.20 W
1762-IR44 RTD or resistance channels41.5 W0.38 W
1762-IT44 thermocouple or mV channels41.5 W0.38 W

Where this module sits: it prints 3.4 W for its 32 sourcing dc outputs, which is heat level 6 of 9 among the fifteen 1762 expansion modules. That level is shared with 1762-OV32T, so the printed heat does not separate those pages - the point count and the output type do. The level above it is 3.7 W on the 1762-IQ8, 1.09 times this figure. The level below is 2.9 W on the 1762-OB16, which is 1.17 times lighter. This page prints its capacity as "32 sourcing dc outputs".

Six slots filled with this module would radiate 20.4 W inside the enclosure; the same six slots filled with the 1762-IT4 or 1762-IR4 at 1.5 W would radiate 9.0 W. Both arrangements pass the printed rule, because the rule is counted in modules and not in watts: every page in this family prints the same "6 modules maximum from the supply" line. What the rule protects is the bus; what the enclosure has to absorb is the sum above, and only the first of the two is printed here.

The useful reading of this table is that geometry never varies inside the family - every one of the fifteen pages prints the same 90 mm height (110 mm with the mounting tabs), 87 mm depth and 40 mm width - so the six-module rule is always 240 mm of rail, and the only thing that changes from module to module is heat.

What the printed data does not carry: none of these fifteen pages prints the +5 V dc or +24 V dc current this module draws from the system power supply, none prints inrush, and none prints the supply budget of the controller the module hangs on. The printed heat is therefore the only load figure available here, and a bus budget cannot be closed from it.

Source: the field tables printed on the fifteen 1762 product pages on this site (catalog number, capacity, heat dissipation, dimensions, power supply distance) and Rockwell publication 1762-UM003, cited on each of those pages; no figure in this table is calculated or estimated.

Related numbers

The Allen-Bradley MicroLogix 1200 1762 controllers category groups the other catalog numbers, options and spare parts in the same range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)