Product Details:
Payment & Shipping Terms:
|
1763-L16AWA is the 120/240V ac version of the MicroLogix 1100: ten 120V ac digital inputs, two 0…10V dc analog inputs and six relay outputs, with an Ethernet port built into the controller.
The 1100 was the first MicroLogix with Ethernet on the CPU, which is why it stayed in panels long after serial-only controllers were replaced — the program and the HMI could both live on the plant network without a gateway.
| 1763-L16AWA | MicroLogix 1100 16 point controller | IN STOCK |
| 1763-NC01 | Channel 0 to RS-485 cable | IN STOCK |
| 1763-MM1 | Memory module | IN STOCK |
| 1763-BA | Replacement lithium battery | IN STOCK |
Catalog number |
1763-L16AWA |
Description |
MicroLogix 1100 16 point controller |
I/O |
(10) 120V ac digital inputs, (2) 0…10V dc analog inputs, (6) relay outputs |
Input power |
100…240V ac, -15/+10 %, 47…63 Hz |
Maximum power consumption |
46 VA |
Power supply inrush |
120V ac 25 A for 8 ms, 240V ac 40 A for 4 ms |
Dimensions |
90 mm high (104 mm with DIN latch open), 110 mm wide, 87 mm deep |
Shipping weight |
0.9 kg |
Analog input resolution |
10 bit, 0…1,023 counts over 0…10.0V dc, ±1.0 % of full scale |
Analog input impedance |
210 kΩ, overvoltage protection to 10.5V dc |
Relay contact rating |
240V ac 7.5 A make / 0.75 A break, 2.5 A continuous |
Ports |
Isolated RS-232/485 combination port plus 10/100 Ethernet port |
Expansion allowance |
800 mA at 5V dc and 700 mA at 24V dc |
Operating temperature |
-20…65 °C |
Storage temperature |
-40…85 °C |
Lifecycle status |
Discontinued April 30, 2022 |
Replacement category |
Engineering Replacement |
UPC |
662074023028 |
Publication |
1763-UM001 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1763-UM001 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Ten 120V ac digital inputs, two analog inputs and six relay outputs — 18 points on the brick, with the analog channels sharing the same terminal block as the digital inputs.
The analog inputs are 0…10V dc only, 10-bit, 210 kΩ impedance, ±1.0 % of full scale over the operating temperature range. They are not configurable to current loops; a 4…20 mA sensor needs a shunt resistor or a 1762 analog module.
Relay outputs are rated 7.5 A make and 0.75 A break at 240V ac, 2.5 A continuous. That is a general-purpose contact, not a motor starter: contactors and solenoids belong on an interposing relay.
The Ethernet port is 10/100 with a fixed IP configured through the programming software, and it carries programming, messaging and HMI traffic at the same time. There is no web server and no email client on this model.
Channel 0 is an isolated combination RS-232/485 port: DF1 full duplex, DH-485, Modbus RTU and ASCII are all available from it. 1763-NC01 breaks the 8-pin DIN connector out to a 6-pin Phoenix RS-485 terminal.
Input power is 100…240V ac at 47…63 Hz with -15/+10 % tolerance; maximum consumption is 46 VA. Inrush is 25 A for 8 ms at 120V ac and 40 A for 4 ms at 240V ac, which matters when several controllers share one breaker.
The controller will supply 800 mA at 5V dc and 700 mA at 24V dc to 1762 expansion modules. There is no 24V dc sensor supply on this version — the ac-input brick takes 120V ac signals directly.
90 mm high, 104 mm with the DIN latch open, 110 mm wide, 87 mm deep, 0.9 kg shipping weight. Mount horizontally with 50 mm of free space on all sides for ventilation.
Operating range -20…65 °C, storage -40…85 °C, humidity 5…95 % non-condensing, vibration 5 g over 10…500 Hz, shock 30 g. Terminal screw torque is 0.56 N·m.
1763-L16AWA was discontinued on April 30, 2022 with an Engineering Replacement as the replacement category. The whole MicroLogix 1100 line ended on the same date, with the battery following on April 01, 2022.
The functional successor is the Micro800 family with embedded Ethernet. The 1100 remains common in existing panels, so the practical options are a tested spare, a documented migration, or a like-for-like unit.
What I/O does 1763-L16AWA have?
Ten 120V ac digital inputs, two 0…10V dc analog inputs and six relay outputs.
Does 1763-L16AWA have Ethernet?
Yes — a 10/100 Ethernet port plus an isolated RS-232/485 combination port.
What power supply does 1763-L16AWA need?
100…240V ac, 47…63 Hz, 46 VA maximum consumption.
Is 1763-L16AWA still available from Rockwell?
No. Discontinued April 30, 2022; replacement category Engineering Replacement.
Can 1763-L16AWA read a 4…20 mA sensor?
Not directly. The analog inputs are 0…10V dc only.
1763-L16AWA is a MicroLogix controller, a self contained unit that combines the power supply, the processor, embedded I/O and the communication ports, so the figures below describe the whole assembly rather than a single card in a chassis. All values are taken from the Rockwell controller manual for this bulletin.
| Specification | Value |
|---|---|
| Catalog number | 1763-L16AWA |
| Input power | 100 to 240V AC, minus 15 percent to plus 10 percent, at 47 to 63 Hz |
| Number of I/O | 12 inputs (10 digital and 2 analog) and 6 outputs |
| Embedded discrete inputs | 10 at 120V AC |
| Embedded analog inputs | 2 voltage inputs, 0 to 10V DC |
| Embedded discrete outputs | 6 relay |
| 24V DC sensor power | None on this variant |
| Communication ports | Isolated combination RS-232/RS-485 port, plus Ethernet |
| Dimensions H x W x D | 90 x 110 x 87 mm (3.5 x 4.33 x 3.43 in.) |
| Shipping weight | 0.9 kg (2.0 lb.) |
| Power supply inrush | 120V AC: 25 A for 8 ms; 240V AC: 40 A for 4 ms |
| Maximum power consumption | 46 VA |
| Operating temperature | -20 to 65 degrees C ambient |
| Storage temperature | -40 to 85 degrees C ambient |
| Vibration | 10 to 500 Hz, 5 g, 0.015 in. peak to peak, 2 hours per axis |
| Shock | 30 g operating, 50 g non-operating panel mounted, 40 g DIN rail mounted |
| Terminal screw torque | 0.56 N m (5.0 in lb.) rated |
| Output pilot duty | C300 and R150 hazardous location, B300 and R150 ordinary location |
| Relay life, mechanical | 10,000,000 cycles |
| Source | 1763-UM001 controller user manual, Appendix A specifications |
The 1100 series carries ten 120V AC inputs, two 0 to 10V analog inputs and six relay outputs in a housing only 110 mm wide, which is what makes it a candidate for a small machine or a remote panel where a full rack would not fit. Expansion runs to the right through the 1762 bus, so the controller stays the power and communication source for the whole assembly.
Its operating range starts at minus twenty degrees C, and the relay contacts are rated for both hazardous location and ordinary pilot duty. Together those two lines decide whether the controller can sit in an unheated shelter and whether a contactor coil can be driven directly or needs an interposing relay.
Three numbers decide most of the engineering on a controller like this: the input power and its inrush, because that sizes the supply and the protective device; the embedded point count and type, because that decides how many field devices are wired directly; and the clearance envelope, because that decides whether the unit fits the panel that already exists.
Inrush current is the number that trips a breaker on a cold morning. An AC powered controller that draws tens of amperes for a few milliseconds needs a supply and a protective device sized for that pulse, not for the steady state VA figure on the nameplate.
Mounting clearance is part of the thermal design. Fifty millimetres on every side is the published figure, and a controller bolted tight against a wireway will run hotter than the specification assumes, which shortens the life of the internal supply long before any I/O fails.
A MicroLogix controller is a complete package: power supply, processor, embedded I/O and communication ports in one housing that mounts on a DIN rail or a panel. Nothing here is a card in a chassis, so the specification table reads differently from an I/O module page: input power, embedded point count, communication ports and enclosure dimensions all matter at once.
The 24V user supply, where it exists, is for input devices only. Feeding output circuits from it is the mistake that destroys the internal supply, and the manuals state the restriction explicitly because the temptation is real when a panel has spare milliamps.
These controllers expand to the right through an expansion bus, and the expansion modules are the 1762 family rather than a second controller. Power budgeting therefore happens across the whole assembly, and the expansion cable and the end cap belong on the order with the first module.
The AC input version is chosen when the machine already switches 120V control circuits. It removes the need for a separate 24V sensor supply, but it also means every field device carries line voltage, so the wiring practice around the terminal block is the same as for a 120V relay panel.
Communication is built in rather than added: an Ethernet port for programming and messaging, plus serial ports that cover RS-232 and RS-485 without an external converter. On a retrofit this removes the gateway that used to sit in the panel, and it also removes the point of failure that gateway represented.
Operating temperature for this generation is quoted down to minus twenty degrees C, which is unusual for an AC powered device and relevant for outdoor cabinets and unheated shelters. The storage range is wider still, so a controller that has sat in a cold store can be energised without a warm-up ritual.
Relay outputs are the reason these controllers survive in mixed panels. A relay contact does not care whether the load is 24V DC, 120V AC or a small contactor coil, and the published pilot duty ratings are what a panel builder uses to decide whether a starter can be driven directly or needs an interposing relay.
The memory module is a removable program store, so a replacement controller can be commissioned without a laptop. It is a service part rather than an expansion part, and the procedure is to power down, transfer the module, and confirm the program and the recipe data before returning the machine to production.
Terminal torque is specified because a loose terminal block screw fails intermittently for months. The published value is the target for the rated screw, and a torque screwdriver is cheaper than the downtime caused by a high resistance joint that only shows up under load.
Relay life is quoted mechanically and electrically, and the two numbers are far apart. Twenty million mechanical operations is a mechanical endurance figure; the electrical life depends on the load, the inrush and the arc, which is why contactor coils and incandescent lamps shorten the life of the same contact.
Battery low is a countdown, not a warning light to be noted. The published behaviour is that the controller keeps the program and the clock for about two weeks from the first indication, after which the data is at risk, so a spare battery in the cabinet is a maintenance item rather than an option.
Check the panel width against 110 mm plus 50 mm of clearance, confirm the pilot duty rating against the contactor coil, and keep the battery and the memory module in the spares list.
This part sits in the Allen-Bradley MicroLogix 1100 1763 controllers category, with the other models and spare parts listed alongside it.