logo
Home ProductsAB MicroLogix 1100 1763

Allen Bradley PLC 1763-BA / 1763BA

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1763-BA / 1763BA

China Allen Bradley PLC 1763-BA / 1763BA supplier
Allen Bradley PLC 1763-BA / 1763BA supplier Allen Bradley PLC 1763-BA / 1763BA supplier Allen Bradley PLC 1763-BA / 1763BA supplier Allen Bradley PLC 1763-BA / 1763BA supplier Allen Bradley PLC 1763-BA / 1763BA supplier Allen Bradley PLC 1763-BA / 1763BA supplier

Large Image :  Allen Bradley PLC 1763-BA / 1763BA

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1763-BA / 1763BA

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $25.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1763-BA technical data PDF download 1763-BA Rockwell MicroLogix 1100 Replacement Battery

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: MicroLogix 1100 / 1763

1763-BA is the replacement lithium battery for the MicroLogix 1100, backing up the real time clock and retentive data while the controller is unpowered.

It is the cheapest part in the panel and the one whose failure is noticed last — as a clock that resets to 2000 on every power cycle, taking timestamped fault records with it.

1763-L16AWA MicroLogix 1100 16 point controller IN STOCK
1763-NC01 Channel 0 to RS-485 cable IN STOCK
1763-MM1 Memory module IN STOCK
1763-BA Replacement lithium battery IN STOCK

Product Specifications 1763-BA (PDF)
 Catalog number
 1763-BA
 Description
 Replacement lithium battery for the MicroLogix 1100
 Function
 Backs up the real time clock and retentive memory
 Used with
 MicroLogix 1100 controllers
 Lifecycle status
 Discontinued April 01, 2022
 Replacement category
 Engineering Replacement
 UPC
 612598329816
 Warranty
 1 year standard
 Publication
 1763-UM001

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1763-UM001 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1763-BA 1763-BA 1763-BA 1763-BA 1763-BA 1763-BA 1763-BA

What it backs up

The real time clock and the retentive data area. Program memory is Flash and does not depend on the battery.

When the battery fails the controller still runs. What changes is that the clock resets on power-up and any timestamped fault or trend data becomes misleading.

Replacement

The battery is a user-replaceable item in the controller's battery compartment. Replace it with power applied where the procedure allows, so the clock and retentive data survive the swap.

Record the replacement date. A lithium cell in this role lasts years, not decades, and the failure mode is silent.

Availability

1763-BA was discontinued on April 01, 2022, a month before the rest of the MicroLogix 1100 line, with the replacement category Engineering Replacement.

Batteries are also a shipping-restricted item: a cell bought from stock may not be shippable by air, which affects delivery time more than price.

Stocking advice

Keep one spare per controller population, not per controller. The cells age on the shelf as well as in the panel.

Check the date code before fitting. A cell that sat in a warehouse for years arrives closer to end of life than the one it replaces.

Related parts

1763-L16AWA is the controller, 1763-MM1 the memory module and 1763-NC01 the RS-485 cable.

For controllers that hold program memory in RAM rather than Flash, the battery has a second role — check the manual for the specific model before assuming it is only a clock cell.

FAQ — 1763-BA

What is 1763-BA?

The replacement lithium battery for the MicroLogix 1100.

What does 1763-BA back up?

The real time clock and retentive data; program memory is Flash.

Is 1763-BA still available from Rockwell?

No. Discontinued April 01, 2022; replacement category Engineering Replacement.

What happens when the battery fails?

The controller runs, but the clock resets on power-up.

How many spares should be stocked?

One per controller population — the cells age on the shelf.


Data sources. Function comes from the Rockwell product page of 1763-BA; battery-backed clock behaviour follows 1763-UM001. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1763-BA: MicroLogix 1100 replacement battery

1763-BA is a Rockwell service part for the MicroLogix family, documented here from the controller manual rather than from a catalogue summary, so that the compatibility, the function and the installation sequence are on one page.

SpecificationValue
Catalog number1763-BA
FunctionReplaceable lithium battery for the controller
What it holdsReal-time clock reference and program retention while the controller is unpowered
Low indicationBattery Low indicator on the LCD, plus the RTC:0/BL function file bit
Time to failure after indicationAbout 2 weeks; the manual notes 8 hours without a battery is the exposure if power is not continuous
InstallationInsert the battery in the pocket with the wires facing up, plug the wire connector into the battery connector, dress the wires along the guide
HandlingDo not charge, do not short the terminals, dispose of cells only by the recommended procedures
Related warningConnecting or disconnecting a cell can arc, so the area must be non-hazardous before the connector is handled
Source1763-UM001 controller user manual, Appendix B replacement parts

Two weeks is the whole maintenance window. The controller keeps the clock and the retention for roughly that long after the first low indication, and the program itself is in non-volatile memory, so the loss that actually hurts is the time base and the data that depends on it.

The install is three steps and none of them are difficult, which is exactly why the handling rules deserve the space: a primary lithium cell that is charged, shorted or disposed of incorrectly is a personnel hazard rather than a controller fault.

For a service part the engineering question is narrow: which controller it fits, what it restores, and what the procedure costs in downtime. The table above answers the first two from the manual, and the procedure answers the third in steps that can be followed with the enclosure open.

A spare parts kit for a small controller is cheap compared with the cost of waiting. One memory module, one battery and one communication cable cover the three failures that stop a machine without any diagnostic message on the display.

A service part is ordered against a symptom, not against a catalog page. The questions that matter are which controller the part fits, what it actually restores, and how long the machine can stay down while it is fitted, and those three answers are the reason this page exists rather than a line in a price list.

Arc hazard during battery connection is a hazardous location issue, not a battery issue. Connecting or disconnecting a cell in a classified area can produce a spark, so the manual requires the area to be known non-hazardous before the connector is touched.

Program and recipe data are two different things in the backup question. A module image restores the program logic, while the current recipe may live in data that has moved since the image was taken, so the restore procedure has to state which of the two is being reloaded.

The distinction between backup and capacity is the one that costs money. A memory module that stores a copy of the program and the data does not enlarge the controller, so a project that has outgrown its memory cannot be rescued with an accessory; it needs a different controller.

Cable part numbers that carry a Series letter are not interchangeable with earlier series in classified locations. The manual states which series is required for Class I Division 2, and substituting an older cable because it fits is the kind of short cut that fails an inspection.

The port cover is part of the environmental rating. Removing it to fit a module and leaving it off exposes the connector to dust and to accidental contact, and the manual assumes the cover is back in place when the panel door is closed.

Transport is the second function of these parts. A module programmed in the workshop and carried to site turns a commissioning visit into an installation task, and it also gives the maintenance team a known good image to fall back on when a controller is replaced under pressure.

Termination impedance is built into the communication cable rather than added as a resistor. On a DH-485 segment that detail is what keeps reflections out of the signal, and it is why an arbitrary cable of the right length is not an acceptable substitute.

Field replacement of these parts happens with the controller de-energised. Reading the manual procedure before opening the enclosure is faster than discovering, mid-swap, that the connector is keyed or that the wires must be dressed along a guide.

Battery indications are a deadline rather than a status. The controller publishes roughly two weeks from the first low indication, and the clock data is what is actually at risk, because the program itself is held in non-volatile memory and the battery exists to keep the clock and the retention alive.

Cable length is quoted per segment and per node, and the two limits are different. A single point to point link tolerates a much longer run than a multi-drop segment, and the specification that applies is the one for the topology actually installed.

Documentation for accessories is a page in the controller manual rather than a separate publication, which is why the figures here are quoted from that manual. When a customer asks for the source, the manual section is the reference, and the catalog number is only the ordering key.

Stock one cell per controller, replace on the first low indication rather than at the outage, and dispose of the removed cell by the recommended route.

The Allen-Bradley MicroLogix 1100 1763 controllers category lists the related catalog numbers, options and accessories for this range.