1766-MM1 is the memory module for the MicroLogix 1400: 384 KB of separate storage for program, data, datalog and recipe files.
It is a back-up and transport device, not an expansion. The 1400's own program and data are already non-volatile, so the module adds a copy that can be stored apart from the controller.
| 1766-L32AWA | Controller, 20 ac inputs, 12 relay outputs | IN STOCK |
| 1766-L32AWAA | Controller, 20 ac inputs, 12 relay outputs, analog I/O | IN STOCK |
| 1766-L32BWA | Controller, 12 fast + 8 standard dc inputs, 12 relay outputs | IN STOCK |
| 1766-MM1 | Memory module, 384 KB back-up | IN STOCK |
Catalog number |
1766-MM1 |
Description |
Memory module for the MicroLogix 1400 |
Memory size |
384 KB |
Backs up |
User program, user data, datalog and recipe |
Additional features |
Program compare, data file download protection, write protection |
Insertion |
Removal and insertion under power supported |
Effect on controller memory |
None — the module does not increase available controller memory |
Country of origin |
Singapore |
Lifecycle status |
Active Mature |
Estimated lead time |
5 days |
UPC |
612598589708 |
Warranty |
1 year standard |
Publication |
1766-UM001 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1766-UM001 (module specifications) and 1766-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
User program, user data, datalog and recipe back-up. One module carries one program set.
It also supports program compare against the running program, download protection on data files and write protection — the three features that turn a back-up into something you can trust at a panel.
The controller's program and data are stored in non-volatile memory and survive power loss. The module provides additional back-up that can be kept separately; it does not increase the available memory of the controller.
That distinction matters when specifying: a larger program needs a different controller, not a bigger module.
The module fits the port on the controller after the port cover is removed. Removal and insertion under power are supported, which means a back-up can be refreshed on a running machine.
Refresh it after every program change. A module holding last year's logic restores last year's machine with complete confidence, which is worse than having none.
Active Mature, with a published five day lead time and stock originating in Singapore.
Because the 1400 itself is still orderable, this module is one of the few accessories in the MicroLogix range that can be bought new rather than hunted on the secondary market.
Controllers: 1766-L32AWA, 1766-L32AWAA, 1766-L32BWA. Expansion: 1762 Compact I/O modules, up to seven.
Communication: 1763-NC01 for RS-485 on channel 0.
How much memory does 1766-MM1 hold?
384 KB.
Does 1766-MM1 increase controller memory?
No. It provides a separate back-up only.
Is 1766-MM1 still available from Rockwell?
Yes. Lifecycle status Active Mature, lead time 5 days.
Can 1766-MM1 be fitted with power on?
Yes — removal and insertion under power are supported.
What does 1766-MM1 back up?
User program, user data, datalog and recipe files.
1766-MM1 is a Rockwell service part for the MicroLogix family, documented here from the controller manual rather than from a catalogue summary, so that the compatibility, the function and the installation sequence are on one page.
| Specification | Value |
|---|---|
| Catalog number | 1766-MM1 |
| Function | Memory module, optional backup of the user program and data |
| Memory size | 384 KB |
| Compatibility | MicroLogix 1400 controllers; one memory module type is available for the family |
| Capacity effect | Does not increase the available memory of the controller |
| Second use | Transport of programs between controllers |
| Installation | Remove the port cover, align the connector with the pins, seat firmly; a screwdriver is used later to remove it |
| Removal caution | Removing the module during a data transaction can corrupt data |
| Source | 1766-UM001 controller user manual, memory module section |
The published size is 384 KB, and the manual is equally clear about what that size is not: it is a copy of the program and data, not extra working memory. An application that has outgrown the controller stays outgrown, and buying this module to solve a memory problem is a wasted purchase.
Where it earns its cost is transport and recovery. A module carried from the workshop to the panel turns commissioning into a load-and-verify step, and the same module gives a maintenance team a known good image when a controller has to be swapped at three in the morning.
For a service part the engineering question is narrow: which controller it fits, what it restores, and what the procedure costs in downtime. The table above answers the first two from the manual, and the procedure answers the third in steps that can be followed with the enclosure open.
Cable part numbers that carry a Series letter are not interchangeable with earlier series in classified locations. The manual states which series is required for Class I Division 2, and substituting an older cable because it fits is the kind of short cut that fails an inspection.
The port cover is part of the environmental rating. Removing it to fit a module and leaving it off exposes the connector to dust and to accidental contact, and the manual assumes the cover is back in place when the panel door is closed.
Transport is the second function of these parts. A module programmed in the workshop and carried to site turns a commissioning visit into an installation task, and it also gives the maintenance team a known good image to fall back on when a controller is replaced under pressure.
Termination impedance is built into the communication cable rather than added as a resistor. On a DH-485 segment that detail is what keeps reflections out of the signal, and it is why an arbitrary cable of the right length is not an acceptable substitute.
Field replacement of these parts happens with the controller de-energised. Reading the manual procedure before opening the enclosure is faster than discovering, mid-swap, that the connector is keyed or that the wires must be dressed along a guide.
Battery indications are a deadline rather than a status. The controller publishes roughly two weeks from the first low indication, and the clock data is what is actually at risk, because the program itself is held in non-volatile memory and the battery exists to keep the clock and the retention alive.
Cable length is quoted per segment and per node, and the two limits are different. A single point to point link tolerates a much longer run than a multi-drop segment, and the specification that applies is the one for the topology actually installed.
Documentation for accessories is a page in the controller manual rather than a separate publication, which is why the figures here are quoted from that manual. When a customer asks for the source, the manual section is the reference, and the catalog number is only the ordering key.
Handling rules for lithium cells are not paperwork. Shorting the terminals, attempting to charge a primary cell, or puncturing a pack in a hazardous area are the three ways these parts injure people, and the procedures in the manual address each of them separately.
A spare parts kit for a small controller is cheap compared with the cost of waiting. One memory module, one battery and one communication cable cover the three failures that stop a machine without any diagnostic message on the display.
A service part is ordered against a symptom, not against a catalog page. The questions that matter are which controller the part fits, what it actually restores, and how long the machine can stay down while it is fitted, and those three answers are the reason this page exists rather than a line in a price list.
Arc hazard during battery connection is a hazardous location issue, not a battery issue. Connecting or disconnecting a cell in a classified area can produce a spark, so the manual requires the area to be known non-hazardous before the connector is touched.
Program and recipe data are two different things in the backup question. A module image restores the program logic, while the current recipe may live in data that has moved since the image was taken, so the restore procedure has to state which of the two is being reloaded.
Order the module with the spare controller, program the image before the panel is closed, and never buy it to solve a memory shortage.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley MicroLogix 1400 1766 controllers category.