logo
Home ProductsAB CompactLogix 1769

Allen Bradley PLC 1768-CNBR / 1768CNBR

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1768-CNBR / 1768CNBR

China Allen Bradley PLC 1768-CNBR / 1768CNBR supplier
Allen Bradley PLC 1768-CNBR / 1768CNBR supplier Allen Bradley PLC 1768-CNBR / 1768CNBR supplier Allen Bradley PLC 1768-CNBR / 1768CNBR supplier Allen Bradley PLC 1768-CNBR / 1768CNBR supplier Allen Bradley PLC 1768-CNBR / 1768CNBR supplier

Large Image :  Allen Bradley PLC 1768-CNBR / 1768CNBR

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1768-CNBR / 1768CNBR

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $692.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1768-CNBR technical data PDF download 1768-CNBR / 1768CNBR ControlNet Bridge Redundant Media

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Module

The 1768-CNBR is the redundant-media ControlNet bridge for the 1768 backplane: two BNC trunk ports, 48 Logix connections, 99 nodes, 1 A at 5.2V DC.

The second channel is the whole reason for the part. On a trunk where a coax break would stop the line, channel A and channel B run on separate cables and the module keeps the scheduled traffic going on the surviving one.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1768-CNBR (PDF)
 Application
 ControlNet bridge, redundant media, for 1768-L4x controllers
 Cat Num
 1768-CNBR
 Brand Name
 Rockwell
 ControlNet communication rate
 5 Mbps
 Logix communication connections
 48
 Number of nodes, max
 99
 Current draw @ 5.2V DC
 1 A
 Current draw @ 24V DC
 0 mA
 Power dissipation
 5.14 W
 Thermal dissipation
 17.5 BTU/hr
 Isolation voltage
 30V, functional, ControlNet to backplane
 Ports
 2 ControlNet BNC, 1 ControlNet RJ45
 Cable
 Quad shield RG6 coaxial
 Weight, approx
 0.293 kg
 Dimensions (H * W * D)
 132 * 56.7 * 105.1 mm
 Slot width
 1

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1768-CNBR ControlNet redundant bridge module, factory packaging 1768-CNBR module front view with two BNC ports 1768-CNBR label detail showing catalog number

How the redundancy works

Two BNC ports, two trunks. Channel A and channel B connect to physically separate RG6 cables; a single cable fault leaves the other channel carrying the segment. One channel for nonredundant media. Rockwell's guidance: while both channels are active, use channel A for nonredundant media rather than splitting a single trunk across both ports. The bridge stays a single node. Redundancy is in the media path, not in a second controller — 48 Logix connections and 99 nodes are unchanged from the CNB.

Same electrical figures as the CNB

1 A at 5.2V DC, 0 mA at 24V DC. Nothing added for the second BNC port. 5.14 W dissipation, 17.5 BTU/hr. Identical thermal load, so a panel designed for a CNB needs no extra cooling for a CNBR. 0.293 kg instead of 0.260 kg. The only physical difference: 33 g for the second connector and its shell.

Cabling practice

Quad shield RG6 on both channels. Taps and terminators from the 1786 family; keep the two trunks physically separated so one event does not damage both. 1786-CP for programming. The RJ45 port takes the ControlNet programming cable, not an Ethernet connection. Terminate both ends of each trunk. A redundant segment is two complete trunks, each with its own terminators — not one trunk split in two.

Isolation and environment

30V functional isolation. ControlNet to backplane, tested at 500V AC for 60 s; the NAP-to-backplane path has no isolation. 0...60 °C, 5...95% RH. 5 g vibration, 30 g operating shock, 6 kV contact and 8 kV air ESD immunity. T4A, open style. Class I Division 2 Groups A, B, C, D, CE to EN 61326-1 and EN 61131-2, CI conformance tested.

When to specify it

The trunk already exists and is redundant. Retrofits into a redundant ControlNet line are the common case. The process cannot stop for a cable fault. Where a coax break would take the line down, the second channel is cheaper than the downtime. Not for new Ethernet designs. Where the panel is being built on EtherNet/IP, 1768-ENBT is the module and DLR or Stratix switching handles the redundancy.

FAQ — 1768-CNBR

What does the 1768-CNBR add over the 1768-CNB?

A second BNC port for redundant media on two separate trunks, at the same 48 connections, 99 nodes and 5.14 W dissipation.

How much does the 1768-CNBR weigh?

0.293 kg against 0.260 kg for the 1768-CNB; dimensions are identical at 132 * 56.7 * 105.1 mm.

Does the 1768-CNBR double the connection count?

No. It remains a single node with 48 Logix connections and 99 nodes maximum; only the media path is redundant.

Which cable is used on the 1768-CNBR?

Quad shield RG6 coaxial cable on both channels, with 1786 taps and terminators for each trunk.

What is the thermal load of the 1768-CNBR?

5.14 W of dissipation, published as 17.5 BTU/hr, the same as the 1768-CNB.

Is the 1768-CNBR certified for ControlNet?

Yes, ControlNet International conformance tested, with c-UL-us, CE, C-Tick and KC markings.


Data sources. Technical values on this page come from Rockwell publication 1769-TD007 (CompactLogix Communication Modules Specifications, publication 1769-TD007D-EN-P, May 2014), current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The three 1768 communication modules on current and thermal load

The table puts the three 1768 module records that print current side by side, cell by cell, in the wording each record uses - which is the only way to see where the wording diverges as well as the numbers.

Catalog numberRole as printedCurrent at 5.2 VCurrent at 24 VPower consumptionPower dissipationLogix connections
1768-ENBTEtherNet/IP bridge834 mA0 mA4.34 W4.38 W128
1768-EWEBEnhanced web server834 mA0 mA4.34 W4.38 W128
1768-CNBRControlNet bridge, redundant media1 A0 mAnot printed5.14 W48

Where this module sits: its application sentence reads "ControlNet bridge, redundant media, for 1768-L4x controllers". On the 5.2 V rail it prints 1 A and on the 24 V rail 0 mA, with 48 Logix connections against a slot width of 1. Its dissipation is 5.14 W.

This is the only one of the three module records that prints a thermal figure in BTU per hour and the only one that prints a node limit, 99 nodes on the ControlNet segment. It also prints two BNC ports and one RJ45 port where the Ethernet records print a single RJ45, and its quad shield RG6 coaxial cable requirement is printed nowhere else in the family.

Slot width is the column that decides how many of these fit beside a controller: each module takes one slot, and a standard 1768 controller allows two 1768 modules while the safety controllers allow four. The communication limit printed on every controller record is two, so the expansion ceiling is reached by communication modules before it is reached by slots.

What these three records do not carry: no cable length or connector pinout beyond the port description, no supported media list, no firmware version, no current figure for the 24 V side beyond the printed zero, and no thermal margin against a chassis limit.

Source: the field tables printed on the 1768-ENBT, 1768-EWEB and 1768-CNBR records on this site; the connection counts, currents, wattages, port descriptions and dimensions are quoted from the record each belongs to, and a cell reads "not printed" where that record carries no such row.

Related numbers

Browse the Allen-Bradley CompactLogix 1769 controllers category for the other models, options and spare parts that share this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)