Product Details:
Payment & Shipping Terms:
|
The 1768-EWEB is the enhanced web server module for the 1768 CompactLogix backplane: custom web pages served from the controller's tags, 64 TCP/IP connections, 834 mA at 5.2V DC.
Rockwell discontinued it on 31 January 2020 with an engineering replacement, so the remaining supply is used stock — for a project that already specifies custom web pages served from the PLC, it is the only 1768 module that does that.
| 1769-IA16 | Compact 16-point 120V AC input module | IN STOCK |
| 1769-IQ16 | Compact 16-point 24V DC sink/source input module | IN STOCK |
| 1769-IQ32 | Compact 32-point 24V DC sink/source input module | IN STOCK |
| 1769-OA16 | Compact 16-point 120/240V AC output module | IN STOCK |
| 1769-OB16 | Compact 16-point 24V DC output module | IN STOCK |
| 1769-OB32 | Compact 32-point 24V DC output module | IN STOCK |
| 1769-OW16 | Compact 16-point relay output module | IN STOCK |
| 1769-IF4 | Compact 4-channel analog input module | IN STOCK |
| 1769-IF8 | Compact 8-channel analog input module | IN STOCK |
| 1769-IF16C | Compact 16-channel current input module | IN STOCK |
| 1769-OF4 | Compact 4-channel analog output module | IN STOCK |
| 1769-OF8V | Compact 8-channel voltage output module | IN STOCK |
| 1769-OF8C | Compact 8-channel current output module | IN STOCK |
| 1769-ARM | Compact address reserve module | IN STOCK |
Application |
Enhanced web server for 1768-L4x and 1768-L4xS controllers |
Cat Num |
1768-EWEB |
Brand Name |
Rockwell |
EtherNet/IP communication rate |
10/100 Mbps |
Logix communication connections |
128 |
TCP/IP communication connections |
64 |
Current draw @ 5.2V DC |
834 mA |
Current draw @ 24V DC |
0 mA |
Power consumption |
4.34 W |
Power dissipation |
4.38 W |
Isolation voltage |
30V, functional, Ethernet to system |
Ports |
1 Ethernet RJ45, Category 5 |
Weight, approx |
0.213 kg |
Dimensions (H * W * D) |
132 * 56.7 * 105.1 mm |
Slot width |
1 |
Product status |
Discontinued by Rockwell, 31 January 2020 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Is the 1768-EWEB still in production?
No. Rockwell discontinued it on 31 January 2020 and lists an engineering replacement; remaining units are used or surplus stock.
How many connections does the 1768-EWEB support?
128 Logix connections and 64 TCP/IP connections at 10/100 Mbps through one RJ45 port.
Can the 1768-EWEB control I/O?
No. It is a web server and message bridge without I/O support; distributed 1769 I/O uses the 1769-AENTR adapter.
What current does the 1768-EWEB draw?
834 mA at 5.2V DC, 0 mA at 24V DC, 4.34 W consumption and 4.38 W dissipation.
What is the difference between 1768-ENBT and 1768-EWEB?
Both bridge EtherNet/IP with the same connection pools and current; the EWEB additionally serves custom web pages from controller tags.
Which controllers take the 1768-EWEB?
The 1768-L43, 1768-L45, 1768-L43S and 1768-L45S, in one 1768 backplane slot.
The table puts the three 1768 module records that print current side by side, cell by cell, in the wording each record uses - which is the only way to see where the wording diverges as well as the numbers.
| Catalog number | Role as printed | Current at 5.2 V | Current at 24 V | Power consumption | Power dissipation | Logix connections |
| 1768-ENBT | EtherNet/IP bridge | 834 mA | 0 mA | 4.34 W | 4.38 W | 128 |
| 1768-EWEB | Enhanced web server | 834 mA | 0 mA | 4.34 W | 4.38 W | 128 |
| 1768-CNBR | ControlNet bridge, redundant media | 1 A | 0 mA | not printed | 5.14 W | 48 |
Where this module sits: its application sentence reads "Enhanced web server for 1768-L4x and 1768-L4xS controllers". On the 5.2 V rail it prints 834 mA and on the 24 V rail 0 mA, with 128 Logix connections against a slot width of 1. Its dissipation is 4.38 W.
Every electrical and physical figure on this page is identical to the 1768-ENBT record - same currents, same 4.34 W and 4.38 W, same connection counts, same port, same weight and the same 132 by 56.7 by 105.1 mm. What separates them is the role sentence and this record's own status row, which reads "Discontinued by Rockwell, 31 January 2020" - so the web-server function is the one that was withdrawn while the plain Ethernet bridge record prints no lifecycle row at all.
The three module records answer the same question in three different ways: the two Ethernet records print a consumption figure and a dissipation figure a hundredth of a watt apart, while the ControlNet record prints only dissipation, plus a BTU per hour figure the others do not have. A thermal sum built from the consumption column alone would therefore leave the ControlNet bridge out entirely.
What these three records do not carry: no cable length or connector pinout beyond the port description, no supported media list, no firmware version, no current figure for the 24 V side beyond the printed zero, and no thermal margin against a chassis limit.
Source: the field tables printed on the 1768-ENBT, 1768-EWEB and 1768-CNBR records on this site; the connection counts, currents, wattages, port descriptions and dimensions are quoted from the record each belongs to, and a cell reads "not printed" where that record carries no such row.
The Allen-Bradley CompactLogix 1769 controllers category groups the other catalog numbers, options and spare parts in the same range.