The 1768-PB3 is the 24V DC power supply for the 1768 CompactLogix backplane: 16.8...31.2V DC input, 90 W of output, 22 W dissipated, 1.01 kg.
It is the DC-input counterpart of the 1768-PA3, and the reason to choose it is usually the panel's power architecture — a 24V DC bus that already exists, rather than an AC feed brought in for the PLC alone.
| 1769-IA16 | Compact 16-point 120V AC input module | IN STOCK |
| 1769-IQ16 | Compact 16-point 24V DC sink/source input module | IN STOCK |
| 1769-IQ32 | Compact 32-point 24V DC sink/source input module | IN STOCK |
| 1769-OA16 | Compact 16-point 120/240V AC output module | IN STOCK |
| 1769-OB16 | Compact 16-point 24V DC output module | IN STOCK |
| 1769-OB32 | Compact 32-point 24V DC output module | IN STOCK |
| 1769-OW16 | Compact 16-point relay output module | IN STOCK |
| 1769-IF4 | Compact 4-channel analog input module | IN STOCK |
| 1769-IF8 | Compact 8-channel analog input module | IN STOCK |
| 1769-IF16C | Compact 16-channel current input module | IN STOCK |
| 1769-OF4 | Compact 4-channel analog output module | IN STOCK |
| 1769-OF8V | Compact 8-channel voltage output module | IN STOCK |
| 1769-OF8C | Compact 8-channel current output module | IN STOCK |
| 1769-ARM | Compact address reserve module | IN STOCK |
Application |
1768 backplane power supply, 24V DC input |
Cat Num |
1768-PB3 |
Brand Name |
Rockwell |
Input voltage |
16.8…31.2V DC |
Input power |
112 W |
Output power |
90 W |
Power dissipation |
22 W |
Weight, approx |
1.01 kg |
Modules per side |
8 |
Mounting |
DIN rail or panel |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
What input voltage does the 1768-PB3 accept?
16.8...31.2V DC, the standard 24V DC industrial window.
How much power does the 1768-PB3 deliver?
90 W of output from 112 W of input, dissipating 22 W in the process.
How many modules does the 1768-PB3 feed?
Up to eight modules on each side of the backplane.
What is the difference between 1768-PA3 and 1768-PB3?
Input: PA3 takes 85...265V AC or 108...132V DC and dissipates 30 W; PB3 takes 16.8...31.2V DC and dissipates 22 W. Both deliver 90 W.
How heavy is the 1768-PB3?
Approximately 1.01 kg, against 0.98 kg for the 1768-PA3.
Where is the 1768-PB3 mounted in the backplane?
At the left of the 1768 assembly, ahead of the communication or motion modules and the controller.
What output power does the 1768-PB3 provide?
90 W, from 112 W of input power, with 22 W dissipated as heat.
Can one 1768-PB3 feed two backplanes?
No. It feeds one 1768 backplane, up to eight modules on each side; a second backplane needs its own supply.
1768-PB3 is a module for the 1768 CompactLogix backplane, documented here from the Rockwell controller manual and the integrated motion specification so that the electrical, network and timing limits sit on one page.
| Specification | Value |
|---|---|
| Catalog number | 1768-PB3 |
| Function | Single input power supply for the 1768 backplane |
| Input voltage range | 16.8 to 31.2V DC |
| Comparison to 1768-PA3 | 1768-PA3 accepts 86 to 265V AC and 108 to 132V DC dual input |
| Output to the backplane | 24V DC to the controller in slot 0 |
| Distribution | The controller converts 24V DC to 5V and 24V DC and distributes it to 1769 I/O on the right and 5V to communication or motion modules on the left |
| Backplane requirement | One power supply per 1768 backplane |
| Distance rating | None between the 1768 modules and the power supply |
| Status indicator | PWR: off means no adequate input or supply off, steady red means the supply cannot produce valid 24V |
| Diagnostic sequence | Remove all modules, prove the supply alone, reinstall motion and communication modules, then remove them one at a time |
| Source | 1768-UM001 CompactLogix controller user manual, power supply section |
The input range is the entire selection argument: 16.8 to 31.2V DC suits a plant that already distributes 24V, and the AC alternative is there for panels that only have line power. Putting a DC input supply on an unbacked 24V bus means the controller drops out at the same instant as everything else on that bus.
One supply serves the whole backplane and it does not drive the modules directly. The 24V goes to the controller, which generates the 5V and 24V rails, so the loading calculation is a controller calculation and the supply is only responsible for its input and its conversion.
The engineering question for a module in this backplane is always the same three: which rail it draws from, how it is addressed or connected, and what its published limit is. The table answers those from the Rockwell documents, and the notes below carry what the figures mean on a running machine.
A SERCOS interface module is a deterministic motion bus, and its cycle time is a function of the data rate and the axis count. Half a millisecond with two drives at four megabits, one millisecond with four, and half a millisecond with four at eight megabits: those three numbers are the whole timing envelope, and a machine with a fast cam profile lives or dies on them.
Certification for a module in a control backplane includes the hazardous location listing, and the file numbers are the evidence a panel inspector asks for. Having them on the page saves the argument that starts when the certificate has to be found at commissioning.
There is no distance rating between the 1768 modules and the supply, which is a statement about the backplane rather than about wiring. Ribbon cable extension of a 1769 I/O bank has a published distance limit; the 1768 modules bolted to the same backplane do not, and confusing the two leads to an unfounded worry or a real mistake depending on which family is being extended.
Axis capacity is bound to the controller, not to the module. One module in a 1768-L43 gives four real axes, two feedback axes and six virtual axes; two modules in a 1768-L45 give eight, four and six. The virtual axes are not free hardware, they are a programming convenience, and a project that counts them as real axes will run out of capacity.
A motion module has one slot width, so the physical cost of adding an axis pair is a centimetre of DIN rail plus the fiber. What does not scale linearly is the engineering: the cam tables, the registration and the safety of the axis group all have to be rethought when the axis count doubles.
The PWR indicator is a diagnostic sequence, not a lamp. Steady red means the supply cannot produce valid 24V, and the documented procedure is to strip the system back, prove the supply alone, then add modules in groups until the fault reappears. Following that order is faster than swapping parts at random.
The fiber between the module and the drives is plastic optical fiber in three jacket variants, chosen for the routing rather than for the data rate. Non-jacketed cable suits a short run inside a cabinet, a standard PVC jacket suits general routing, and a nylon jacket is the option for abrasion and for tight bends, and all three are ordered by length.
The 1768 backplane is short and strictly ordered: the power supply on the left, communication and motion modules next, the controller in slot 0, and the 1769 I/O to the right. Slots are numbered right to left from the controller, which is the detail that decides where a module physically sits when the rack is drawn in a quotation.
A ControlNet bridge in this backplane exists to move produced and consumed data between a local controller and remote chassis, and its connection count is the practical limit. Sixty four connections with five rack optimized producers and five listen-only consumers is a number a network design has to stay inside, and it is published per module rather than per network.
Current draw at 24V is zero on this module because it runs from the 5V rail, and that matters to the power budget arithmetic: the module consumes from one rail only, so adding a second motion module changes the 5V calculation and leaves the 24V calculation untouched.
One power supply per backplane, and it does not feed the modules directly. It delivers 24V DC to the controller, and the controller converts that to the 5V and 24V rails that the communication and motion modules and the 1769 I/O actually use, so the power budget belongs to the controller rather than to the supply alone.
Two EtherNet/IP modules can be fitted per controller, which is enough for a device level ring or for separating a plant network from a machine network. Beyond two, the architecture has to change, either to a larger controller or to a gateway, and that is a design decision rather than a purchasing one.
The environmental envelope is stated with the IEC test numbers behind it, from operating cold to thermal shock. That is what allows a cabinet in an unheated building to be signed off against a standard rather than against an opinion, and it is why the storage range is quoted separately from the operating range.
Match the input range to the bus that actually feeds the panel, count the load on the controller rails rather than on the supply, and use the PWR sequence before replacing hardware.
Browse the Allen-Bradley CompactLogix 1769 controllers category for the other models, options and spare parts that share this range.