Product Details:
Payment & Shipping Terms:
|
20AC060A0NYNACC0 is a PowerFlex 70 in the 400 V class at the 60 A rating: 30 kW, 40 Hp, frame E.
Its build differs from the plain 20AC060A0AYNANC0 in ControlNet (coax). The power stage is the same across the family, so the differences are in the option slots only.
Quick answer. 20AC060A0NYNACC0 is a PowerFlex 70 drive, 400 V AC class, 60 A normal duty (30 kW / 40 Hp), frame E, A - Panel mount, IP 20, NEMA/UL Type 1.
| 20AC060G3AYNANC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060F0AYNANC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060C0AYNANC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A3AYNANC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A3AYNAEC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A3AYNADC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A0NYNACC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A0AYNANC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060C3AYNANC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A3AYNANC1 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A3AYNACC0 | 60 A / 30 kW, frame E | IN STOCK |
| 20AC060A0AYNADC0 | 60 A / 30 kW, frame E | IN STOCK |
Catalog number |
20AC060A0NYNACC0 |
Voltage class |
400 V AC, 3-phase, 6-pulse |
Normal duty output current |
60 A |
Normal duty motor rating |
30 kW / 40 Hp |
Frame size |
E |
Enclosure (d) |
A - Panel mount, IP 20, NEMA/UL Type 1 |
HIM (e) |
0 - Blank cover |
Documentation (f) |
N - No manual |
Brake IGBT (g) |
Y - Brake IGBT fitted |
Internal brake resistor (h) |
N - No internal brake resistor |
Emission class (i) |
A - Filtered |
Comm slot (j) |
C - ControlNet (coax) |
Control and I/O (k) |
C - Enhanced control, no safe-off |
Feedback (l) |
0 - No feedback, enhanced control |
Source |
20A-UM001 p.10 catalog explanation |
20AC060A0NYNACC0 (PowerFlex 70, 400 V class 3-phase, 60 A / 30 kW / 40 HP, Frame E): a drive with a blank cover instead of a Human Interface Module, ControlNet communication slot, and enhanced control (no Safe-Off). The enclosure is Panel Mount, IP 20 / NEMA-UL Type 1, and no internal brake resistor is fitted.
What that means on the panel: the drive stays inside a cabinet and relies on the panel for its Type 1 rating. Turning to the option set, the drive becomes a ControlNet node on a coax trunk shared with the controller, and enhanced control adds the extended parameter files and the encoderless options, without the safety option. On a high-inertia load the drive will trip on bus overvoltage during deceleration unless a suitable external dynamic brake resistor is added and parameter 163 [DB Resistor Type] is set for it. All voltage and rating values come from the 400 V class rows of the Rockwell catalogue-number table; the digits after the control code are not interpreted here, so match the nameplate before ordering a replacement. Sources: Rockwell publication 20A-UM001 (catalog number explanation and 240 V or 400 V drive ratings).
Attribute values above for 20AC060A0NYNACC0 are reproduced from the manufacturer's product data. For the authoritative technical record see the PowerFlex 70 User Manual, publication 20A-UM001, and the PowerFlex 70 Technical Data, publication 20A-TD001; mounting and wiring are in the Installation Instructions, publication 20A-IN009. Certification details, with certificate and file numbers, are listed in the FAQ below.
The string is 20A (drive), C (400 V AC 3-phase), 060 (rating), then nine option positions d to l.
Here: d=A, e=0, f=N, g=Y, h=N, i=A, j=C, k=C, l=0.
Rockwell prints each position as its own table on page 10 of 20A-UM001; decoding by eye is where most used-drive listings go wrong.
Enclosure (d) decides the mounting: Panel mount, IP 20, NEMA/UL Type 1.
HIM (e): Blank cover. The LCD keypad is removable, so a used drive can arrive with a blank cover.
Brake IGBT (g): Brake IGBT fitted; internal brake resistor (h): No internal brake resistor. On 20AC060A0NYNACC0 the two characters are read together, because both are needed before a holding brake can be wired straight to the drive.
Comm slot (j): ControlNet (coax). Control and I/O (k): Enhanced control, no safe-off. Feedback (l): No feedback, enhanced control.
Normal duty 60 A, 30 kW / 40 Hp on frame E.
Frame sets the heatsink, fan and terminal spacing, so a frame change is also a panel-space change.
What to verify before buying used Nameplate catalog number, full 16 characters, against this page - one letter of 20AC060A0NYNACC0 changes the enclosure or the network option.
Safe-off builds (k=G) carry a second terminal pair; a standard-control drive does not.
Encoder interface (l=1) is a separate board; it is not CE EMC certified when fitted.
Every code above is transcribed from the Catalog Number Explanation, page 10 of Rockwell publication 20A-UM001.
No field on this page is inferred from a distributor listing; positions Rockwell leaves blank are not published and are not shown as data.
What is 20AC060A0NYNACC0?
PowerFlex 70, 400 V, 60 A / 30 kW, frame E, panel mount.
What is the output current of 20AC060A0NYNACC0?
60 A normal duty at 400 V.
Which frame is 20AC060A0NYNACC0?
Frame E, 30 kW / 40 Hp normal duty.
Does 20AC060A0NYNACC0 have a network slot?
ControlNet (coax).
What enclosure is 20AC060A0NYNACC0?
Panel mount, IP 20, NEMA/UL Type 1.
Related catalog numbers in the same rating code. Same 60 A A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.
20AC060G3AYNANC0 (60 A / 30 kW, frame E) · 20AC060F0AYNANC0 (60 A / 30 kW, frame E) · 20AC060C0AYNANC0 (60 A / 30 kW, frame E) · 20AC060A3AYNANC0 (60 A / 30 kW, frame E) · 20AC060A3AYNAEC0 (60 A / 30 kW, frame E) · 20AC060A3AYNADC0 (60 A / 30 kW, frame E) · 20AC060A0AYNANC0 (60 A / 30 kW, frame E) · 20AC060C3AYNANC0 (60 A / 30 kW, frame E) · 20AC060A3AYNANC1 (60 A / 30 kW, frame E)
Related models, options and spare parts for this range are listed in the Allen-Bradley PowerFlex drives and motors category.