|
Product Details:
Payment & Shipping Terms:
|
20AC037F0AYNANC0 is a PowerFlex 70 in the 400 V class at the 37 A rating: 18.5 kW, 25 Hp, frame D.
Its build differs from the plain 20AC037A0AYNANC0 in flange mount. The power stage is the same across the family, so the differences are in the option slots only.
Quick answer. 20AC037F0AYNANC0 is a PowerFlex 70 drive, 400 V AC class, 37 A normal duty (18.5 kW / 25 Hp), frame D, F - Flange mount, front IP 20, rear heatsink IP 66.
| 20AC037F0AYNANC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037C3AYNANC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037C0AYNANC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYYADG0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYNANC1 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYNADC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYNACC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A0AYNANC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYNANC0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYNAEG0 | 37 A / 18.5 kW, frame D | IN STOCK |
| 20AC037A3AYNAEC0 | 37 A / 18.5 kW, frame D | IN STOCK |
Catalog number |
20AC037F0AYNANC0 |
Voltage class |
400 V AC, 3-phase, 6-pulse |
Normal duty output current |
37 A |
Normal duty motor rating |
18.5 kW / 25 Hp |
Frame size |
D |
Enclosure (d) |
F - Flange mount, front IP 20, rear heatsink IP 66 |
HIM (e) |
0 - Blank cover |
Documentation (f) |
A - Manual included |
Brake IGBT (g) |
Y - Brake IGBT fitted |
Internal brake resistor (h) |
N - No internal brake resistor |
Emission class (i) |
A - Filtered |
Comm slot (j) |
N - None |
Control and I/O (k) |
C - Enhanced control, no safe-off |
Feedback (l) |
0 - No feedback, enhanced control |
Source |
20A-UM001 p.10 catalog explanation |
20AC037F0AYNANC0 (PowerFlex 70, 400 V class 3-phase, 37 A / 18.5 kW / 25 HP, Frame D): a drive with a blank cover instead of a Human Interface Module, no communication slot fitted, and enhanced control (no Safe-Off). The enclosure is Flange Mount, front chassis IP 20 / heat sink rear IP 66, and no internal brake resistor is fitted.
What that means on the panel: the drive splits its heat sink through the cabinet wall so the panel stays cooler. Turning to the option set, control is by hard-wired digital inputs and an analog reference only, and enhanced control adds the extended parameter files and the encoderless options, without the safety option. On a high-inertia load the drive will trip on bus overvoltage during deceleration unless a suitable external dynamic brake resistor is added and parameter 163 [DB Resistor Type] is set for it. All voltage and rating values come from the 400 V class rows of the Rockwell catalogue-number table; the digits after the control code are not interpreted here, so match the nameplate before ordering a replacement. Sources: Rockwell publication 20A-UM001 (catalog number explanation and 240 V or 400 V drive ratings).
Attribute values above for 20AC037F0AYNANC0 are reproduced from the manufacturer's product data. For the authoritative technical record see the PowerFlex 70 User Manual, publication 20A-UM001, and the PowerFlex 70 Technical Data, publication 20A-TD001; mounting and wiring are in the Installation Instructions, publication 20A-IN009. Certification details, with certificate and file numbers, are listed in the FAQ below.
The string is 20A (drive), C (400 V AC 3-phase), 037 (rating), then nine option positions d to l.
Here: d=F, e=0, f=A, g=Y, h=N, i=A, j=N, k=C, l=0.
Rockwell prints each position as its own table on page 10 of 20A-UM001; decoding by eye is where most used-drive listings go wrong.
Enclosure (d) decides the mounting: Flange mount, front IP 20, rear heatsink IP 66.
HIM (e): Blank cover. The LCD keypad is removable, so a used drive can arrive with a blank cover.
Brake IGBT (g): Brake IGBT fitted; internal brake resistor (h): No internal brake resistor. On 20AC037F0AYNANC0 the two characters are read together, because both are needed before a holding brake can be wired straight to the drive.
Comm slot (j): None. Control and I/O (k): Enhanced control, no safe-off. Feedback (l): No feedback, enhanced control.
Normal duty 37 A, 18.5 kW / 25 Hp on frame D.
Frame sets the heatsink, fan and terminal spacing, so a frame change is also a panel-space change.
What to verify before buying used Nameplate catalog number, full 16 characters, against this page - one letter of 20AC037F0AYNANC0 changes the enclosure or the network option.
Safe-off builds (k=G) carry a second terminal pair; a standard-control drive does not.
Encoder interface (l=1) is a separate board; it is not CE EMC certified when fitted.
Every code above is transcribed from the Catalog Number Explanation, page 10 of Rockwell publication 20A-UM001.
No field on this page is inferred from a distributor listing; positions Rockwell leaves blank are not published and are not shown as data.
What is 20AC037F0AYNANC0?
PowerFlex 70, 400 V, 37 A / 18.5 kW, frame D, flange mount.
What is the output current of 20AC037F0AYNANC0?
37 A normal duty at 400 V.
Which frame is 20AC037F0AYNANC0?
Frame D, 18.5 kW / 25 Hp normal duty.
Does 20AC037F0AYNANC0 have a network slot?
None.
What enclosure is 20AC037F0AYNANC0?
Flange mount, front IP 20, rear heatsink IP 66.
Related catalog numbers in the same rating code. Same 37 A A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.
20AC037C3AYNANC0 (37 A / 18.5 kW, frame D) · 20AC037C0AYNANC0 (37 A / 18.5 kW, frame D) · 20AC037A3AYYADG0 (37 A / 18.5 kW, frame D) · 20AC037A3AYNANC1 (37 A / 18.5 kW, frame D) · 20AC037A3AYNADC0 (37 A / 18.5 kW, frame D) · 20AC037A3AYNACC0 (37 A / 18.5 kW, frame D) · 20AC037A0AYNANC0 (37 A / 18.5 kW, frame D) · 20AC037A3AYNANC0 (37 A / 18.5 kW, frame D) · 20AC037A3AYNAEG0 (37 A / 18.5 kW, frame D)
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley PowerFlex drives and motors category.