logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 20AC015A0AYNADG0

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 20AC015A0AYNADG0

China Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier
Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier Allen Bradley PowerFlex 20AC015A0AYNADG0 supplier

Large Image :  Allen Bradley PowerFlex 20AC015A0AYNADG0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20AC015A0AYNADG0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1122.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20AC015A0AYNADG0 technical data PDF download 20AC015A0AYNADG0 PowerFlex 70 Drive, 15.4 A / 7.5 kW

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PowerFlex 70 drives

20AC015A0AYNADG0 is a PowerFlex 70 in the 400 V class at the 15.4 A rating: 7.5 kW, 10 Hp, frame C.

Its build differs from the plain 20AC015A0AYNANC0 in DeviceNet, safe-off. The power stage is the same across the family, so the differences are in the option slots only.

Quick answer. 20AC015A0AYNADG0 is a PowerFlex 70 drive, 400 V AC class, 15.4 A normal duty (7.5 kW / 10 Hp), frame C, A - Panel mount, IP 20, NEMA/UL Type 1.

  • Normal duty output current: 15.4 A
  • Motor rating: 7.5 kW / 10 Hp
  • Frame: C
  • Enclosure: A - Panel mount, IP 20, NEMA/UL Type 1
  • Communication slot: D - DeviceNet
  • Control and I/O: G - Enhanced control with safe-off
20AC015C0AYNANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYYANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYYAEC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNANC1 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNAEG0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNAEC1 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNAEC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNADG1 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYYANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYNANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYNAEC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYNADG0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015F0AYNANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015C3AYYANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015C3AYNANC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNADC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A3AYNACC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYNANC1 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYNADC0 15.4 A / 7.5 kW, frame C IN STOCK
20AC015A0AYNACC0 15.4 A / 7.5 kW, frame C IN STOCK

Product Specifications 20AC015A0AYNADG0 (PDF)
 Catalog number
 20AC015A0AYNADG0
 Voltage class
 400 V AC, 3-phase, 6-pulse
 Normal duty output current
 15.4 A
 Normal duty motor rating
 7.5 kW / 10 Hp
 Frame size
 C
 Enclosure (d)
 A - Panel mount, IP 20, NEMA/UL Type 1
 HIM (e)
 0 - Blank cover
 Documentation (f)
 A - Manual included
 Brake IGBT (g)
 Y - Brake IGBT fitted
 Internal brake resistor (h)
 N - No internal brake resistor
 Emission class (i)
 A - Filtered
 Comm slot (j)
 D - DeviceNet
 Control and I/O (k)
 G - Enhanced control with safe-off
 Feedback (l)
 0 - No feedback, enhanced control
 Source
 20A-UM001 p.10 catalog explanation

Attribute values above for 20AC015A0AYNADG0 are reproduced from the manufacturer's product data. For the authoritative technical record see the PowerFlex 70 User Manual, publication 20A-UM001, and the PowerFlex 70 Technical Data, publication 20A-TD001; mounting and wiring are in the Installation Instructions, publication 20A-IN009. Certification details, with certificate and file numbers, are listed in the FAQ below.

20AC015A0AYNADG0 20AC015A0AYNADG0 20AC015A0AYNADG0 20AC015A0AYNADG0 20AC015A0AYNADG0 20AC015A0AYNADG0 20AC015A0AYNADG0

How to read this catalog number

The string is 20A (drive), C (400 V AC 3-phase), 015 (rating), then nine option positions d to l.

Here: d=A, e=0, f=A, g=Y, h=N, i=A, j=D, k=G, l=0.

Rockwell prints each position as its own table on page 10 of 20A-UM001; decoding by eye is where most used-drive listings go wrong.

What each position controls

Enclosure (d) decides the mounting: Panel mount, IP 20, NEMA/UL Type 1.

HIM (e): Blank cover. The LCD keypad is removable, so a used drive can arrive with a blank cover.

Brake IGBT (g): Brake IGBT fitted; internal brake resistor (h): No internal brake resistor. On 20AC015A0AYNADG0 the two characters are read together, because both are needed before a holding brake can be wired straight to the drive.

Comm slot (j): DeviceNet. Control and I/O (k): Enhanced control with safe-off. Feedback (l): No feedback, enhanced control.

Rating and frame

Normal duty 15.4 A, 7.5 kW / 10 Hp on frame C.

Frame sets the heatsink, fan and terminal spacing, so a frame change is also a panel-space change.

What to verify before buying used Nameplate catalog number, full 16 characters, against this page - one letter of 20AC015A0AYNADG0 changes the enclosure or the network option.

Safe-off builds (k=G) carry a second terminal pair; a standard-control drive does not.

Encoder interface (l=1) is a separate board; it is not CE EMC certified when fitted.

Documented source

Every code above is transcribed from the Catalog Number Explanation, page 10 of Rockwell publication 20A-UM001.

No field on this page is inferred from a distributor listing; positions Rockwell leaves blank are not published and are not shown as data.

FAQ — 20AC015A0AYNADG0

What is 20AC015A0AYNADG0?

PowerFlex 70, 400 V, 15.4 A / 7.5 kW, frame C, panel mount.

What is the output current of 20AC015A0AYNADG0?

15.4 A normal duty at 400 V.

Which frame is 20AC015A0AYNADG0?

Frame C, 7.5 kW / 10 Hp normal duty.

Does 20AC015A0AYNADG0 have a network slot?

DeviceNet.

What enclosure is 20AC015A0AYNADG0?

Panel mount, IP 20, NEMA/UL Type 1.

Related catalog numbers in the same rating code. Same 15.4 A A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.

20AC015C0AYNANC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYYANC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYYAEC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNANC1 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNANC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNAEG0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNAEC1 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNAEC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNADG1 (15.4 A / 7.5 kW, frame C) · 20AC015A0AYYANC0 (15.4 A / 7.5 kW, frame C)


Data sources. For 20AC015A0AYNADG0, decoded from Rockwell 20A-UM001 p.10 Catalog Number Explanation, with the rating rows taken from the 400 V 50 Hz table on the same page. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

20AC015A0AYNADG0: PowerFlex 70, 400V three-phase

20AC015A0AYNADG0 is a PowerFlex 70 adjustable frequency drive in the 400V class. The catalog number reads 20A for the family, C for the 400V three-phase rating, 015 for the output current code, and the trailing positions for HIM, filter, brake and feedback options.

AttributeValue
Catalog number20AC015A0AYNADG0
FamilyPowerFlex 70, bulletin 20A
Voltage class400V AC, three-phase, six-pulse
Current code015
FrameC
Normal duty7.5 kW (10 Hp)
Heavy duty5.5 kW (7.5 Hp)
Input current15.1 A
Input kVA10.4 kVA
Output current15.4 / 17.2 / 23.1 A (cont. / 60 s / 3 s)
Dual element time delay fuse20...30 A dual element, 20...60 A non-time delay
Circuit breaker60 A max
Motor circuit protector20 A max
140M / 140MT protector140M-C2E-C16 / 140M-D8E-C16 / 140M-F8E-C16
Minimum enclosure3,441 in3 minimum enclosure

The normal duty and heavy duty columns above are the same hardware at two thermal ratings, and the output current row gives the continuous, 60 second and 3 second values that a drive selection is actually checked against. A load that needs 130 percent for a minute is checked against the 60 second value, not against the continuous value.

Two duty classes share one frame in this range: normal duty and heavy duty are published against the same hardware, with heavy duty one step below normal duty in kW. Sizing a conveyor on normal duty and then adding a high inertia load is the usual reason a 22 kW drive is found running at 18.5 kW.

Single-phase operation is permitted and defined rather than improvised: under the UL 508C listing the drive can run from a single-phase supply with output current derated by 50 percent of the published three-phase rating. That one sentence turns a three-phase drive into a single-phase drive with half the amps, which is why it settles more retrofit questions than any other line in the bulletin.

Minimum enclosure volume is published per rating because heat dissipation is part of the rating: 3,441 in3 for the 7.5 kW frame C unit and 5,098 in3 for frames D and E. A panel built to a smaller volume is outside the published thermal basis even when the ambient temperature looks acceptable.

For this rating the published branch protection starts at a 20...30 A dual element fuse and a 60 A circuit breaker, with the 140M or 140MT protector listed where the frame supports one. Use the published row rather than a computed value, and confirm the enclosure layout against the 3,441 in3 figure before the panel is designed.

The 400V current codes run 1P3, 2P1, 3P5, 5P0, 8P7, 011, 015, 022, 030, 037, 043, 060 and 072, which are current values rather than a copy of the 480V list. Match the code to the supply first, then check the motor current against the continuous output, then read the option positions for the filter, brake and HIM that the panel actually needs.

Related models, options and spare parts for this range are listed in the Allen-Bradley PowerFlex drives and motors category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)