Allen Bradley PowerFlex 20AB028A3AYNANC0

China Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier
Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier Allen Bradley PowerFlex 20AB028A3AYNANC0 supplier

Large Image :  Allen Bradley PowerFlex 20AB028A3AYNANC0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20AB028A3AYNANC0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1234.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20AB028A3AYNANC0

This page documents catalog number 20AB028A3AYNANC0, a PowerFlex 70 drive in the 240V class, rated 7.5 kw, 10 hp normal duty, frame d. Every value comes from the normal duty rating table and the catalog number explanation in the PowerFlex 70 user manual; nothing is inferred.

Published rating for this code

SpecificationValue
Catalog number20AB028A3AYNANC0
Rating code028
FrameD
Output current at 240V, normal duty28 A
Output current at 208V, normal duty32.2 A
Output power, normal duty7.5 kW, 10 HP
Drive family20A, PowerFlex 70 adjustable frequency AC drive
Voltage class codeB, 240V AC three phase, six pulse
Rating table usedNormal duty, 240V and 208V 60 Hz input, as published in the PowerFlex 70 user manual catalog number explanation
Control code NStandard control; no longer available for sale, per the manual
Control code CEnhanced control, without Safe-Off
Control code GEnhanced control with Safe-Off; not available as a factory installed option on 600V ratings
Frame letterPublished per rating code; frames group several ratings and set the physical size of the drive
Heavy duty ratingsPublished separately from the normal duty table in the same manual, and lower for the same frame

What the published rating decides

The catalog number published in the manual's explanation is a template, ten positions, each with its own table: drive family, voltage class, rating code, control and I/O, brake resistor, human interface, enclosure and filter. Reading three of those positions and calling the number decoded is how an order arrives with the wrong human interface.

Ten horsepower in frame D is the point in this family where the published normal duty rating and the installed motor's service factor start to interact. A motor with a 1.15 service factor is allowed to draw more than its nameplate current, and the published drive rating is the ceiling that the interaction runs into.

The 028 code is the largest normal duty rating in frame D at 240V, sharing the frame with the 022 rating.

Sizing, panel and replacement consequences

Frame D at ten horsepower is the size where a drive starts to need attention to cable length and motor insulation. The published installation data covers both, and neither is a rating row; a drive chosen correctly by current can still fail early because of a cable run that was never considered.

Twenty eight amps is a current that a terminal block accepts comfortably and a lug accepts easily, and the published wire range is wider than the current needs. The constraint at this size is usually the enclosure and the heat, not the conductor, which is why the frame matters as much as the amps.

A drive of this rating is often the one that is replaced in a hurry after a failure, and the published rows that decide a like for like replacement are the frame, the current at both supply voltages, the control code and the brake option. Three of those four are visible on the nameplate; the current at the other voltage is not.

The catalog number carries the voltage class as a single letter, and the same rating code appears under four voltage classes with different currents. A number copied from a drawing without the voltage letter is a number that can be ordered correctly for the wrong supply, which is a mistake that survives a purchase order review.

Published ratings assume a switching frequency and an ambient, and both are adjustable. Raising the carrier frequency to quiet a motor reduces the published current, and a drive selected at its limit has no room for that adjustment; the derating curves are the published answer and they are not in the rating table.

Ten horsepower in frame D is a compact package for the power, and compactness is bought with heat. A sealed enclosure with two of these and a braking resistor is a calculation, and the published ambient figures are the input to it rather than a footnote.

The family's published data is stable across decades while the electronics inside it are not, so a page that records the rating and the options is more useful than a page that describes a control board. Maintenance decisions are made against the rating, the frame and the option codes, and all three are published.

Twenty eight amps at 240 volts and seven point five kilowatts, ten horsepower, is the published normal duty rating of this code, and it is the top of frame D. The code below it, 022, is twenty two amps and five point five kilowatts in the same frame, so the frame is a physical size that covers a range of ratings rather than a rating in itself.

The 208 volt column publishes thirty two point two amps for the same code, which is the current a 208 volt site actually draws at that rating. A panel designed against twenty eight amps and installed at 208 volts is under wired by four amps on a drive that will draw them at full load, and that difference is a published figure rather than a margin.

Ten horsepower at 240 volts is the mid size of a plant's drive population, small enough to be numerous and large enough to need a proper panel. The published frame D sits in that band, and what the panel needs from the page is the frame, the current at both voltages and the fact that the normal and heavy duty ratings differ.

Sharing frame D with the twenty two amp rating means the same mounting and the same footprint carry two ratings, and a machine that is upgraded from seven and a half to ten horsepower can reuse the enclosure. That reuse is legitimate, and it moves the drive closer to its thermal limit inside a box that was sized for the smaller unit.

Normal duty is published against a defined load profile, and a load that starts and stops under torque is heavy duty. The distinction matters most at this size, because a ten horsepower drive on a loaded conveyor is a seven and a half horsepower drive in heavy duty terms, and the published heavy duty table is where that number lives.

Six pulse rectification is published for this voltage class, and the harmonic current that comes with it is a property of the drive rather than a fault. A plant with several drives of this size on one transformer is a plant that may need line reactors, and the published data describes the drive's contribution without prescribing the supply's remedy.

An internal brake resistor option is published in the catalog number, and it changes what the drive can stop. A high inertia load without a resistor decelerates only as fast as the published overvoltage limit allows, and a machine that coasts longer than the process needs is usually a machine without that option.

The enhanced control code and the Safe-Off code are published options with different safety consequences. A drive with Safe-Off removes torque without removing power, which is a different maintenance procedure from an isolation switch, and the code in the catalog number is the only place that distinction is recorded.

The other PowerFlex drives and motors in this range are collected in the Drives and Motors category. This drive can be checked against the shop listing at 20AB028A3AYNANC0.

Neighbouring catalog numbers in this class

These records sit in the same site category as 20AB028A3AYNANC0; catalog numbers that share the most characters with this one are listed first.

Site category: AB Drives. This page is 20AB028A3AYNANC0.

Sources. Rockwell publishes the PowerFlex 70 user manual as 20A-UM001 and the combined PowerFlex 70 and 700 reference material as PFLEX-RM001. The ratings, terminal designations and ordering characters quoted on this page for 20AB028A3AYNANC0 follow those publications.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)