This page documents catalog number 440G-T2NBNPH-1B, a TLS-GD2 positive-mode tongue-operated guard locking switch with an 8-pin micro M12 connector. The published selection matrix places this number in the TLS-1 row at 24 V ac/dc, power to release, without an actuator in the box. It is the escape release variant, which places a release button on the rear of the switch. The family figures below are quoted from the TLS-GD2 installation instructions; the assignment is quoted from the matrix row that carries this number.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-1 |
| Locking principle | power to release |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 24 V ac/dc |
| Actuator | none supplied, order separately |
| Entry | 8-pin micro (M12) connector |
| Escape release | fitted, 50 N maximum operating force |
The other numbers in the same TLS-1 24 V ac/dc group are 440G-T27121 (M20 conduit entry, no actuator supplied), 440G-T27233 (12-pin M23 connector, no actuator supplied).
Escape release, where it applies. On the numbers that carry it, the escape release is a push button on the rear of the switch, published at 50 N maximum operating force, intended for guards with full body access. The switch is mounted so the button is reachable from inside the hazardous area, which makes the mounting orientation part of the safety function rather than a convenience.
Cordset and patchcord. The connection system table names the parts that go with this connector: cordset 889D-F8AB with 2, 5 or 10 m lengths, and patchcord 889D-F8ABDM in the same lengths. Matching the connector is not optional, because an M12 micro receptacle will not accept an M23 cable and a 9-wire cordset is published as usable only with the TLS-3 type through the M23 receptacle, not through this one.
Power to release logic. Power to release means the guard is locked whenever the solenoid is unpowered, and the guard opens only when a signal reaches the solenoid. The published note is that this signal can come from CU1 electronic timer relays or CU2 stopped motion detectors, which is the reason the type exists: machines that do not stop immediately need the guard to stay locked until motion is actually gone. This page covers 440G-T2NBNPH-1B and its ordering options.
| Parameter | Value |
| Catalog number | 440G-T2NBNPH-1B |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T2NBNPH-1B the figures above apply as printed.
Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T2NBNPH-1B the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T2NBNPH-1B the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T2NBNPH-1B the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no cable length beyond the published cordsets is stated, because those follow from the application rather than from the catalog number. Where a figure is absent here it is absent from the source publication for 440G-T2NBNPH-1B as well.
ArmorPoint modules are installed by bridging two bases, which is why every mechanical figure in this family is stated with the base included rather than for the module alone. This page covers 440G-T2NBNPH-1B and its ordering options.
No service life claim and no price is implied. The contact, solenoid and environmental figures are the family values from the TLS-GD2 installation instructions; the type, coil, connector and escape release assignment is the one printed against this catalog number in the selection matrix.
This record is placed against the other three 440G TLS-GD2 guard locking switch records on this site. The first table separates what each page assigns from what it declines to assign, because two of the four numbers are not carried in the published selection matrix; the second table is the only real choice left between the two records that are assigned - the contact budget.
| Catalog number | Matrix row | Safety contacts | Auxiliary contacts | Coil and entry | Escape release | What the page assigns |
| 440G-T2NBNP1-1L | not carried in the matrix | not printed | not printed | not printed | not printed | family figures only |
| 440G-T2NBNP2-1L | not carried in the matrix | not printed | not printed | not printed | not printed | family figures only |
| 440G-T2NBNPH-1B | TLS-1 | 3 N.C. direct opening action | 2 N.O., one of them used for solenoid monitoring | 24 V ac/dc, 8-pin M12 | fitted, 50 N maximum | full row assignment |
| 440G-T2NBNPH-2B | TLS-3 | 4 N.C. direct opening action | 1 N.O. | 24 V ac/dc, 8-pin M12 | fitted, 50 N maximum | full row assignment |
The two assigned rows, side by side.
| Type | Safety contacts | Auxiliary contacts |
| TLS-1 | 3 N.C. | 2 N.O. - one of them for solenoid monitoring |
| TLS-3 | 4 N.C. | 1 N.O. |
Where this record sits: the TLS-1 row of the matrix - three normally closed safety contacts with direct opening action, two normally open auxiliary contacts with one reserved for solenoid monitoring, 24 V ac/dc coil, 8-pin M12 entry, escape release fitted.
Holding force on this family is a property of the bolt material and not of the model: 1,950 N with plastic pins against 2,600 N with steel bolts on Fmax, and 1,500 N against 2,000 N on Fzh. The same switch therefore has two published holding forces that differ by a third, and the page prints which material gives which rather than a single headline figure. Against that, the releasable load is printed at 100 N maximum, and the pages give both figures without stating how the two are meant to combine in a guard design.
What these pages do not carry: no assigned type, coil, entry or actuator on the two NP records, no explanation of what the NP digit group encodes, no coding level beyond the printed low coding, no approach speed figures beyond the 160 mm/s maximum and the 100 mm/min minimum, no statement of how holding force and releasable load combine, and no switch dimensions inside a block that is not borrowed from Point I/O.
The two normally open auxiliary contacts are the reason to choose this row over TLS-3, and one of them is already spent on solenoid monitoring - so the free auxiliary contact count is one, not two. A circuit that wants two independent N.O. signals from this switch has to take the second one off the TLS-3 row, which carries only one.
Source: the shared TLS-GD2 family block and the selection-matrix assignments printed on the four 440G records on this site, which cite ISO 14119, IEC 60947-5-1, EN 1088, NFPA 79 and ANSI B11.19 in the family sheet and the TLS-GD2 installation instructions for the family figures; the holding forces, releasable load, solenoid power, switching ratings, actuation limits, mechanical life, enclosure and temperature ratings, the type and contact assignments and the escape release force are quoted from the records that print them, and the four fields the matrix does not assign are shown as not printed.
Twelve of the 86 440G records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 440G-T2NBNPH-1B.
Group index: Allen Bradley Other PLC. 440G-T2NBNPH-1B is filed under that heading in the site's own product tree. It is the entry point used when a project list is assembled group by group.