logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R

China Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier
Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R supplier

Large Image :  Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R

Product Details:

Place of Origin: Made in DOMINICAN REP
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Guardmaster 440G-T2NBBPH-1R / 440GT2NBBPH1R

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $183.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

440G-T2NBBPH-1R

This page documents catalog number 440G-T2NBBPH-1R, a TLS-GD2 positive-mode tongue-operated guard locking switch with an 8-pin micro M12 connector. The published selection matrix places this number in the TLS-1 row at 24 V ac/dc, power to release, without an actuator in the box. It is the version without the rear escape release. The family figures below are quoted from the TLS-GD2 installation instructions; the assignment is quoted from the matrix row that carries this number.

What the switch is and what it carries

FieldValue
StandardsISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet
Safety classificationType 2 interlocking device with guard locking and low coding (tongue) per ISO 14119
Holding force Fmax1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts
Holding force Fzh1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts
Releasable load100 N (22.5 lbf) maximum
Solenoid power7 W typical at 100 percent duty
Escape release button50 N (11.25 lbf) maximum, escape release versions only
Thermal current10 A; rated insulation voltage 500 V
SwitchingA600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc
Actuation160 mm/s maximum, 100 mm/min minimum, 1 cycle per second
Operating radius160 mm minimum, 80 mm with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations at 100 mA load
EnclosureIP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K
Temperatureminus 20 to plus 60 C
Weight400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator

What this catalog number selects

AttributeValue
TypeTLS-1
Locking principlepower to release
Safety contacts3 N.C. direct opening action
Auxiliary contacts2 N.O., one of them used for solenoid monitoring
Solenoid supply24 V ac/dc
Actuatornone supplied, order separately
Entry8-pin micro (M12) connector
Escape releasenot fitted

Where this number sits in the range

The other numbers in the same TLS-1 24 V ac/dc group are 440G-T27121 (M20 conduit entry, no actuator supplied), 440G-T27233 (12-pin M23 connector, no actuator supplied).

Why this combination exists

The eight pin ceiling. An 8-pin micro connector is the narrowest option in this range and the publication states its consequence plainly: not all contacts are connected. A TLS-1 carries three N.C. safety contacts and two N.O. auxiliary contacts, and those five signals plus a two-wire solenoid do not fit through eight pins without something being dropped. What survives is enough for a dual-channel safety input; what is given up is usually the full set of diagnostics.

Cordset and patchcord. The connection system table names the parts that go with this connector: cordset 889D-F8AB with 2, 5 or 10 m lengths, and patchcord 889D-F8ABDM in the same lengths. Matching the connector is not optional, because an M12 micro receptacle will not accept an M23 cable and a 9-wire cordset is published as usable only with the TLS-3 type through the M23 receptacle, not through this one.

Power to release logic. Power to release means the guard is locked whenever the solenoid is unpowered, and the guard opens only when a signal reaches the solenoid. The published note is that this signal can come from CU1 electronic timer relays or CU2 stopped motion detectors, which is the reason the type exists: machines that do not stop immediately need the guard to stay locked until motion is actually gone. This entry is for 440G-T2NBBPH-1R.

The rear escape release is not part of this number. The same type and coil with that option is published as a separate catalog number in this series, so a guard with full body access cannot be upgraded here after the fact; the option is selected at the order, not added on site.

Environment, mounting and maintenance of the TLS-GD2 switch

ParameterValue
Catalog number440G-T2NBBPH-1R
Enclosure type ratingIP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset
Operating temperature-20...+60 °C (-4...+140 °F)
Housing and actuator materialHousing UL-approved glass-filled PBT; actuator stainless steel
Weight400 g (0.88 lb)
Body length and hole spacing126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes
Mounting bolts, max torque1.4 N·m (12.39 lb·in)
Lid screws, max torque1.2 N·m (10.62 lb·in)
Terminal screws, max torque1.02 N·m (9 lb·in)
Break contact force, min30 N (7 lbf)
Actuation speed100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum
Actuation frequency, max1 cycle/s
Operating radius, min160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations

Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T2NBBPH-1R the figures above apply as printed.

Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T2NBBPH-1R the figures above apply as printed.

IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T2NBBPH-1R the gland fitted at installation is what decides whether the claim holds.

The figures above are family values from 440G-IN022. For 440G-T2NBBPH-1R the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.

No performance level for a machine, no guard cycle count and no cable length beyond the published cordsets is stated, because those follow from the application rather than from the catalog number. Where a figure is absent here it is absent from the source publication for 440G-T2NBBPH-1R as well.

No service life claim and no price is implied. The contact, solenoid and environmental figures are the family values from the TLS-GD2 installation instructions; the type, coil, connector and escape release assignment is the one printed against this catalog number in the selection matrix.

Related catalog numbers in the 440G range

This page links twelve of the 86 440G records on this site; the closest rating codes come first. This page is 440G-T2NBBPH-1R.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 440G-T2NBBPH-1R is listed there beside the rest of the other-PLC group. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)