Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 440G-T2NBBPH-1L, a TLS-GD2 positive-mode tongue-operated guard locking switch with an 8-pin micro M12 connector. The published selection matrix places this number in the TLS-2 row at 24 V ac/dc, power to lock, without an actuator in the box. It is the version without the rear escape release. The family figures below are quoted from the TLS-GD2 installation instructions; the assignment is quoted from the matrix row that carries this number.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-2 |
| Locking principle | power to lock |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 24 V ac/dc |
| Actuator | none supplied, order separately |
| Entry | 8-pin micro (M12) connector |
| Escape release | not fitted |
The other numbers in the same TLS-2 24 V ac/dc group are 440G-T27127 (1/2 inch NPT adaptor, no actuator supplied), 440G-T27239 (12-pin M23 connector, no actuator supplied).
Escape release, where it applies. On the numbers that carry it, the escape release is a push button on the rear of the switch, published at 50 N maximum operating force, intended for guards with full body access. The switch is mounted so the button is reachable from inside the hazardous area, which makes the mounting orientation part of the safety function rather than a convenience.
Why the coil voltage is fixed here. Every number in this series is published with a 24 V ac/dc solenoid. On a machine with a 110 V control circuit that is a constraint rather than a preference: the safety circuit can still be 24 V and the interlock fed from a local supply, but the switch cannot be ordered with a 110 V coil in this connector style, and the 110 V variants live in the conduit-entry series instead.
Power to lock caution. Where the switch is power to lock, the published warning is that provisions may be required so that a dangerous situation cannot result from an open circuit fault or a power cut. A power-to-lock guard stays locked when the supply fails, which is the reverse of what most operators assume a guard does, and the warning is aimed at exactly that gap between expectation and behaviour.
The rear escape release is not part of this number. The same type and coil with that option is published as a separate catalog number in this series, so a guard with full body access cannot be upgraded here after the fact; the option is selected at the order, not added on site.
| Parameter | Value |
| Catalog number | 440G-T2NBBPH-1L |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T2NBBPH-1L the figures above apply as printed.
Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T2NBBPH-1L the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T2NBBPH-1L the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T2NBBPH-1L the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no cable length beyond the published cordsets is stated, because those follow from the application rather than from the catalog number. Where a figure is absent here it is absent from the source publication for 440G-T2NBBPH-1L as well.
No service life claim and no price is implied. The contact, solenoid and environmental figures are the family values from the TLS-GD2 installation instructions; the type, coil, connector and escape release assignment is the one printed against this catalog number in the selection matrix.
Twelve of the 86 440G records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 440G-T2NBBPH-1L.
Group index: Allen Bradley Other PLC. 440G-T2NBBPH-1L is filed under that heading in the site's own product tree. Sibling codes of the same group are one click away from that page.