logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Guardmaster 440G-T27355 / 440GT27355

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Guardmaster 440G-T27355 / 440GT27355

China Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier
Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier Allen Bradley Guardmaster 440G-T27355 / 440GT27355 supplier

Large Image :  Allen Bradley Guardmaster 440G-T27355 / 440GT27355

Product Details:

Place of Origin: Made in DOMINICAN REP
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Guardmaster 440G-T27355 / 440GT27355

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $198.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

440G-T27355

This page documents catalog number 440G-T27355, which belongs to the 440G TLS-GD2 guard locking family. The point worth stating first is what the published selection matrix does not cover: this number is not printed in the matrix rows that assign type, solenoid voltage, entry and actuator, so those four attributes are not claimed here. The shared family figures below are established and quoted; the combination is to be read from the nameplate and the Rockwell catalog before the order is confirmed.

It is worth saying plainly what a page like this can and cannot do. It can give the family figures that every TLS-GD2 shares, and it can point to the sibling numbers whose assignment is published. It cannot tell a buyer which coil is inside a box that left the factory years ago, and a page that guessed would be worse than one that says so.

Shared family data for every TLS-GD2 number

FieldValue
StandardsISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet
Safety classificationType 2 interlocking device with guard locking and low coding (tongue) per ISO 14119
Holding force Fmax1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts
Holding force Fzh1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts
Releasable load100 N (22.5 lbf) maximum
Solenoid power7 W typical at 100 percent duty
Escape release button50 N (11.25 lbf) maximum, escape release versions only
Thermal current10 A; rated insulation voltage 500 V
SwitchingA600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc
Actuation160 mm/s maximum, 100 mm/min minimum, 1 cycle per second
Operating radius160 mm minimum, 80 mm with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations at 100 mA load
EnclosureIP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K
Temperatureminus 20 to plus 60 C
Weight400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator

Reading the number that is not in the matrix

Start from the guard, not the number. Full body access needs the escape release series. A guard that must stay locked after the supply fails needs power to lock and the caution that goes with it. A washdown cell needs the IP69K condition met with rated glands. A modular machine built and tested before shipment wants a connector rather than a gland. Those four questions pick the number; the number does not pick the guard.

What the contact set implies for the safety circuit. The TLS-1 and TLS-2 types carry three N.C. safety contacts with direct opening action and two N.O. auxiliary contacts, one of them monitoring the solenoid. The TLS-3 type carries four N.C. safety contacts and one N.O. auxiliary. A dual-channel safety input can be fed from either type; what differs is how much of the contact set remains available for diagnostics once the solenoid has taken its share.

How to establish the combination. Four marks settle it without guesswork. The nameplate carries the complete catalog number and the switch type. The solenoid coil is marked with its voltage on the coil body. The entry is visible: an M20 thread, a 1/2 inch NPT adaptor or a 12-pin M23 receptacle. The actuator, where one is supplied, is the standard 440G-A27011, the fully flexible 440G-A27143, or one of the flat types ordered separately. Reading those four marks answers the question the matrix would have answered.

Nearest numbers in the range that the matrix does place are 440G-T27262, 440G-T27261, each documented on its own page, so the attribute pattern of this number can be checked against them before an order is placed.

Cordset matching. The connection system in the publication is a short list rather than an open choice: 8-pin micro cordsets 889D-F8AB, 12-wire 12-pin M23 cordsets 889M-F12AH, and a 9-wire 12-pin M23 cordset sold as usable only with the TLS-3. Buying the switch first and the cable second is how a project ends up with a receptacle that cannot carry the contacts it was chosen for.

The rest of the TLS-GD2 range is documented page by page on this site, including the numbers whose type, solenoid, entry and actuator the matrix does state. Where a buyer needs certainty on this one, the honest answer is a nameplate photograph rather than a guess, and that is what this page asks for.

Environment, mounting and maintenance of the TLS-GD2 switch

ParameterValue
Catalog number440G-T27355
Enclosure type ratingIP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset
Operating temperature-20...+60 °C (-4...+140 °F)
Housing and actuator materialHousing UL-approved glass-filled PBT; actuator stainless steel
Weight400 g (0.88 lb)
Body length and hole spacing126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes
Mounting bolts, max torque1.4 N·m (12.39 lb·in)
Lid screws, max torque1.2 N·m (10.62 lb·in)
Terminal screws, max torque1.02 N·m (9 lb·in)
Break contact force, min30 N (7 lbf)
Actuation speed100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum
Actuation frequency, max1 cycle/s
Operating radius, min160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations

The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T27355 the figures above apply as printed.

Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T27355 the figures above apply as printed.

IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27355 the gland fitted at installation is what decides whether the claim holds.

The figures above are family values from 440G-IN022. For 440G-T27355 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.

No performance level for a machine, no guard cycle count and no price is stated. The family figures are quoted from the TLS-GD2 installation instructions; the four attributes that vary by catalog number are left open on this page because the published matrix does not carry this number.

Related catalog numbers in the 440G range

Twelve of the 86 440G records carried on this site, ordered by how close their codes sit to this one. This page is 440G-T27355.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 440G-T27355 page is one entry in it. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)