This page documents catalog number 440G-T27257, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-2 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to lock with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 110 V ac/dc solenoid supply, M20 conduit entry, and GD2 standard actuator 440G-A27011 fitted. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-2 |
| Locking principle | power to lock |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 110 V ac/dc |
| Actuator | GD2 standard actuator 440G-A27011 fitted |
| Entry | M20 conduit entry |
The other numbers in the same TLS-2 110 V ac/dc group are 440G-T27257 (M20 conduit entry, GD2 standard actuator 440G-A27011 fitted), 440G-T27178 (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted). At the same coil, entry and actuator the power to release version is 440G-T27253, and the 24 V ac/dc coil version is 440G-T27255.
Power to lock caution. Where the switch is power to lock, the published warning is that provisions may be required so that a dangerous situation cannot result from an open circuit fault or a power cut. A power-to-lock guard stays locked when the supply fails, which is the reverse of what most operators assume a guard does, and the warning is aimed at exactly that gap between expectation and behaviour.
Field wiring. The UL508 section is three constraints: 75 C copper conductors only, one conduit entrance for field connections, and wiring rated no lower than the ambient where the switch sits in a hot panel. Those constraints decide terminal space and cable selection before the switch type is chosen, and they are the reason an NPT adaptor sometimes wins over a plain metric entry on a US-built machine.
Functional safety. The family data gives B10d above 2 million operations at minimum load, PFHD below 3 x 10^-7 and MTTFd above 385 years, on a stated usage rate of 10 operations per 10 minutes, 24 hours a day, 360 days a year, with a mission time of 38 years. PLe or PLd and SIL 2 or SIL 3 are described as possible depending on architecture, so the switch is a component of a performance level rather than a promise of one.
The rear escape release is not part of 440G-T27257. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.
| Parameter | Value |
| Catalog number | 440G-T27257 |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T27257 the figures above apply as printed.
Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T27257 the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27257 the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T27257 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27257 as well.
No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. This page documents 440G-T27257.
Group index: Allen Bradley Other PLC. 440G-T27257 is filed under that heading in the site's own product tree. Sibling codes of the same group are one click away from that page.