This page documents catalog number 440G-T27240, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-2 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to lock with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 24 V ac/dc solenoid supply, 12-pin M23 connector, and GD2 standard actuator 440G-A27011 fitted. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-2 |
| Locking principle | power to lock |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 24 V ac/dc |
| Actuator | GD2 standard actuator 440G-A27011 fitted |
| Entry | 12-pin M23 connector |
The other numbers in the same TLS-2 24 V ac/dc group are 440G-T27240 (12-pin M23 connector, GD2 standard actuator 440G-A27011 fitted), 440G-T27255 (M20 conduit entry, GD2 standard actuator 440G-A27011 fitted). At the same coil, entry and actuator the power to release version is 440G-T27234.
Power to lock caution. Where the switch is power to lock, the published warning is that provisions may be required so that a dangerous situation cannot result from an open circuit fault or a power cut. A power-to-lock guard stays locked when the supply fails, which is the reverse of what most operators assume a guard does, and the warning is aimed at exactly that gap between expectation and behaviour.
Eight pin limit. The selection data states that with an 8-pin micro connector not all contacts are connected. A switch carrying three N.C. safety contacts and two N.O. auxiliary contacts cannot bring all of them out through eight pins together with the solenoid, so choosing a connector is also choosing which diagnostics survive into the control cabinet. The 9-wire cordset is published as usable only with the TLS-3 versions.
Maintenance. Maintenance is specified at two frequencies rather than one. Weekly: check that the switch operates, look for tampering and inspect the casing for damage. Every six months or more often: isolate power, check terminal tightness, clean out fine dirt, inspect the actuator and cam assembly for wear, and re-apply the tamper-evident varnish. A malfunctioning unit is replaced, not repaired.
The rear escape release is not part of 440G-T27240. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.
| Parameter | Value |
| Catalog number | 440G-T27240 |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T27240 the figures above apply as printed.
Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T27240 the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27240 the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T27240 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27240 as well.
No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. The catalog number covered on this page is 440G-T27240.
Of the 86 440G records carried here, these twelve stand closest to this catalog number. This page is 440G-T27240.
Site tree: the Allen Bradley Other PLC index carries 440G-T27240 together with the other entries of the other-PLC group, which is where a catalogue walk usually starts.