This page documents catalog number 440G-T27172, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-1 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to release with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 110 V ac/dc solenoid supply, 1/2 inch NPT adaptor, and GD2 standard actuator 440G-A27011 fitted. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-1 |
| Locking principle | power to release |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 110 V ac/dc |
| Actuator | GD2 standard actuator 440G-A27011 fitted |
| Entry | 1/2 inch NPT adaptor |
The other numbers in the same TLS-1 110 V ac/dc group are 440G-T27172 (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted), 440G-T27253 (M20 conduit entry, GD2 standard actuator 440G-A27011 fitted). At the same coil, entry and actuator the power to lock version is 440G-T27178, and the 24 V ac/dc coil version is 440G-T27169.
Solenoid duty. The solenoid is published at 7 W typical with 100 percent duty, which means it can stay energised continuously without a derating interval. In a sealed enclosure that 7 W still becomes heat, and a bank of them inside a small cabinet is a temperature rise the panel designer owns, not the switch.
Power to release logic. Power to release means the guard is locked whenever the solenoid is unpowered, and the guard opens only when a signal reaches the solenoid. The published note is that this signal can come from CU1 electronic timer relays or CU2 stopped motion detectors, which is the reason the type exists: machines that do not stop immediately need the guard to stay locked until motion is actually gone. 440G-T27172 is the number described on this page.
Actuator coding. The TLS-GD2 is a Type 2 device with low coding, which means the tongue is coded but not uniquely: a spare actuator of the same type will operate the switch. The publication warns that spare actuators compromise the integrity of the safety system, so an actuator kept in a maintenance drawer is a defeated interlock waiting for someone to try it.
The rear escape release is not part of 440G-T27172. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.
| Parameter | Value |
| Catalog number | 440G-T27172 |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T27172 the figures above apply as printed.
Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T27172 the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27172 the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T27172 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
The keyswitch position is part of the install step, not a label: the base is rotated until the number printed for the module class lines up with the notch, and a module pressed onto a base set for another class is the failure that produces a module which powers up and never appears on the network. 440G-T27172 is the number described on this page.
The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27172 as well.
No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. 440G-T27172 is the number described on this page.
For the surrounding range, open the Allen Bradley Other PLC catalogue index — 440G-T27172 is listed there beside the rest of the other-PLC group. The index sits one level above this page in the site tree.