logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Guardmaster 440G-T27132 / 440GT27132

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Guardmaster 440G-T27132 / 440GT27132

China Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier
Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier Allen Bradley Guardmaster 440G-T27132 / 440GT27132 supplier

Large Image :  Allen Bradley Guardmaster 440G-T27132 / 440GT27132

Product Details:

Place of Origin: Made in DOMINICAN REP
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Guardmaster 440G-T27132 / 440GT27132

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $190.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

440G-T27132

This page documents catalog number 440G-T27132, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-2 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to lock with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 110 V ac/dc solenoid supply, 1/2 inch NPT adaptor, and no actuator supplied. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.

What the switch is and what it carries

FieldValue
StandardsISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet
Safety classificationType 2 interlocking device with guard locking and low coding (tongue) per ISO 14119
Holding force Fmax1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts
Holding force Fzh1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts
Releasable load100 N (22.5 lbf) maximum
Solenoid power7 W typical at 100 percent duty
Escape release button50 N (11.25 lbf) maximum, escape release versions only
Thermal current10 A; rated insulation voltage 500 V
SwitchingA600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc
Actuation160 mm/s maximum, 100 mm/min minimum, 1 cycle per second
Operating radius160 mm minimum, 80 mm with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations at 100 mA load
EnclosureIP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K
Temperatureminus 20 to plus 60 C
Weight400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator

What this catalog number selects

AttributeValue
TypeTLS-2
Locking principlepower to lock
Safety contacts3 N.C. direct opening action
Auxiliary contacts2 N.O., one of them used for solenoid monitoring
Solenoid supply110 V ac/dc
Actuatorno actuator supplied
Entry1/2 inch NPT adaptor

Where this number sits in the range

The other numbers in the same TLS-2 110 V ac/dc group are 440G-T27132 (1/2 inch NPT adaptor, no actuator supplied), 440G-T27178 (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted). At the same coil, entry and actuator the power to release version is 440G-T27124, and the 24 V ac/dc coil version is 440G-T27127.

Why this combination exists

Rotatable head. The head carries two entry slots and rotates to give four actuator entry points, with a blanking plug for the slot that is not used. That is real installation freedom on a guard that is hard to align, and it also imposes a duty: the unused slot has to be plugged, because an open slot invites a second actuator and the publication warns that spare actuators compromise the integrity of the safety system.

Actuation geometry. The published actuation speeds bracket the mechanism at both ends: 160 mm/s maximum and 100 mm/min minimum. A guard that closes slower than the minimum does not actuate reliably, which is why a heavy hinged door on a gas strut needs its closing time measured rather than assumed. The minimum operating radius is 160 mm, or 80 mm with the flexible actuator.

Power to lock caution. Where the switch is power to lock, the published warning is that provisions may be required so that a dangerous situation cannot result from an open circuit fault or a power cut. A power-to-lock guard stays locked when the supply fails, which is the reverse of what most operators assume a guard does, and the warning is aimed at exactly that gap between expectation and behaviour.

The rear escape release is not part of 440G-T27132. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.

Environment, mounting and maintenance of the TLS-GD2 switch

ParameterValue
Catalog number440G-T27132
Enclosure type ratingIP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset
Operating temperature-20...+60 °C (-4...+140 °F)
Housing and actuator materialHousing UL-approved glass-filled PBT; actuator stainless steel
Weight400 g (0.88 lb)
Body length and hole spacing126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes
Mounting bolts, max torque1.4 N·m (12.39 lb·in)
Lid screws, max torque1.2 N·m (10.62 lb·in)
Terminal screws, max torque1.02 N·m (9 lb·in)
Break contact force, min30 N (7 lbf)
Actuation speed100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum
Actuation frequency, max1 cycle/s
Operating radius, min160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations

Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T27132 the figures above apply as printed.

Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T27132 the figures above apply as printed.

IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27132 the gland fitted at installation is what decides whether the claim holds.

The figures above are family values from 440G-IN022. For 440G-T27132 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.

The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27132 as well.

No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. This entry is for 440G-T27132.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 440G-T27132 is listed there beside the rest of the other-PLC group.