This page documents catalog number 440G-T2NBNP1-1L, a TLS-GD2 guard locking switch in the eight-pin micro connector series. The published selection matrix does not print this number in the rows that assign type, coil voltage, entry and actuator, so those are not claimed here. What the family establishes is printed below; the combination is to be read from the nameplate before an order is confirmed.
It is worth saying plainly what a page like this can and cannot do. It can give the family figures that every TLS-GD2 shares, and it can point to the sibling numbers whose assignment is published. It cannot tell a buyer which coil is inside a box that left the factory years ago, and a page that guessed would be worse than one that says so.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
Start from the guard, not the number. Full body access needs the escape release series. A guard that must stay locked after the supply fails needs power to lock and the caution that goes with it. A washdown cell needs the IP69K condition met with rated glands. A modular machine built and tested before shipment wants a connector rather than a gland. Those four questions pick the number; the number does not pick the guard.
What the connector fixes. An 8-pin micro M12 connector cannot bring every contact of a TLS-GD2 out at once, which the publication states directly. Cordsets 889D-F8AB and patchcords 889D-F8ABDM are the published mating parts, in 2, 5 and 10 m lengths. If the application needs the full contact set plus independent solenoid monitoring, the 12-pin M23 numbers are the ones to look at.
Sibling numbers in the same connector. The matrix does place 440G-T2NBBPH-1R, 440G-T2NBBPH-1L, 440G-T2NBBPH-2R in this connector style, and each is documented on its own page, so the pattern of the two letters before the suffix can be checked against them.
Manual release points. The power to release types carry two manual release points fitted with security screws, so a locked switch can be released in an emergency without breaking the housing open. Those points are for maintenance access, not for routine operation, and each use has to be followed by the tamper-evident check the maintenance schedule describes.
| Parameter | Value |
| Catalog number | 440G-T2NBNP1-1L |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T2NBNP1-1L the figures above apply as printed.
Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T2NBNP1-1L the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T2NBNP1-1L the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T2NBNP1-1L the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no price is stated. The family figures are quoted from the installation instructions; the four attributes that vary by number are left open here because the published matrix does not carry this number.
This record is placed against the other three 440G TLS-GD2 guard locking switch records on this site. The first table separates what each page assigns from what it declines to assign, because two of the four numbers are not carried in the published selection matrix; the second table is the only real choice left between the two records that are assigned - the contact budget.
| Catalog number | Matrix row | Safety contacts | Auxiliary contacts | Coil and entry | Escape release | What the page assigns |
| 440G-T2NBNP1-1L | not carried in the matrix | not printed | not printed | not printed | not printed | family figures only |
| 440G-T2NBNP2-1L | not carried in the matrix | not printed | not printed | not printed | not printed | family figures only |
| 440G-T2NBNPH-1B | TLS-1 | 3 N.C. direct opening action | 2 N.O., one of them used for solenoid monitoring | 24 V ac/dc, 8-pin M12 | fitted, 50 N maximum | full row assignment |
| 440G-T2NBNPH-2B | TLS-3 | 4 N.C. direct opening action | 1 N.O. | 24 V ac/dc, 8-pin M12 | fitted, 50 N maximum | full row assignment |
The two assigned rows, side by side.
| Type | Safety contacts | Auxiliary contacts |
| TLS-1 | 3 N.C. | 2 N.O. - one of them for solenoid monitoring |
| TLS-3 | 4 N.C. | 1 N.O. |
Where this record sits: one of the two numbers the published selection matrix does not carry, so the page claims no type, no coil voltage, no entry and no actuator, and says the combination has to be read from the nameplate before an order is confirmed.
The two numbers the matrix does not carry leave the family data as the only content: every 440G-TLS-GD2 record here shares the 7 W solenoid at 100 percent duty, the A600 AC-15 rating at 600 V and 1.2 A, the DC-13 rating at 24 V and 2 A, the minimum 5 mA at 5 V dc, the 1,000,000 operations at 100 mA, the IP66, IP67 and IP69K ratings and the -20 to 60 C range. Family figures are the right thing to publish when the assignment is unknown, and they are also the reason two of these four pages cannot be compared with each other at all.
What these pages do not carry: no assigned type, coil, entry or actuator on the two NP records, no explanation of what the NP digit group encodes, no coding level beyond the printed low coding, no approach speed figures beyond the 160 mm/s maximum and the 100 mm/min minimum, no statement of how holding force and releasable load combine, and no switch dimensions inside a block that is not borrowed from Point I/O.
Read the page for what it refuses to say: the selection matrix does not print this catalog number in the rows that assign type, coil voltage, entry and actuator, so none of those four is claimed anywhere on the record. What is left is the TLS-GD2 family block - holding force, switching capacity, enclosure rating and life - which is true of every number in the family and therefore does not separate this one from its neighbours.
Source: the shared TLS-GD2 family block and the selection-matrix assignments printed on the four 440G records on this site, which cite ISO 14119, IEC 60947-5-1, EN 1088, NFPA 79 and ANSI B11.19 in the family sheet and the TLS-GD2 installation instructions for the family figures; the holding forces, releasable load, solenoid power, switching ratings, actuation limits, mechanical life, enclosure and temperature ratings, the type and contact assignments and the escape release force are quoted from the records that print them, and the four fields the matrix does not assign are shown as not printed.
This page links twelve of the 86 440G records on this site; the closest rating codes come first. This page is 440G-T2NBNP1-1L.
For the surrounding range, open the Allen Bradley Other PLC catalogue index — 440G-T2NBNP1-1L is listed there beside the rest of the other-PLC group.