|
Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 440G-T27261, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-3 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to release with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 2 N.C., a 110 V ac/dc solenoid supply, M20 conduit entry, and GD2 standard actuator 440G-A27011 fitted. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-3 |
| Locking principle | power to release |
| Safety contacts | 4 N.C. direct opening action |
| Auxiliary contacts | 1 N.O. |
| Solenoid supply | 110 V ac/dc |
| Actuator | GD2 standard actuator 440G-A27011 fitted |
| Entry | M20 conduit entry |
The other numbers in the same TLS-3 110 V ac/dc group are 440G-T27261 (M20 conduit entry, GD2 standard actuator 440G-A27011 fitted), 440G-T27184 (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted). At the same coil, entry and actuator the power to release version is 440G-T27253, and the 24 V ac/dc coil version is 440G-T27259.
Manual release points. The power to release types carry two manual release points fitted with security screws, so a locked switch can be released in an emergency without breaking the housing open. Those points are for maintenance access, not for routine operation, and each use has to be followed by the tamper-evident check the maintenance schedule describes.
Cordset matching. The connection system in the publication is a short list rather than an open choice: 8-pin micro cordsets 889D-F8AB, 12-wire 12-pin M23 cordsets 889M-F12AH, and a 9-wire 12-pin M23 cordset sold as usable only with the TLS-3. Buying the switch first and the cable second is how a project ends up with a receptacle that cannot carry the contacts it was chosen for.
Conduit practice. The entry choice follows the plant rather than the switch: an M20 thread is the metric default, the 1/2 inch NPT adaptor exists for North American conduit and hubs, and the M23 connector suits machines built as modules and tested before shipment. Getting this wrong costs an adaptor and a re-termination, and on a stainless washdown machine it can cost the IP69K rating as well.
The rear escape release is not part of 440G-T27261. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.
| Parameter | Value |
| Catalog number | 440G-T27261 |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T27261 the figures above apply as printed.
Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T27261 the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27261 the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T27261 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
The sealed housing is the reason this family exists. An IP67 module on a machine frame removes the cabinet from the field side of the design, and the price of that is that every environmental claim is made per module rather than per enclosure. This entry is for 440G-T27261.
The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27261 as well.
No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. This entry is for 440G-T27261.
This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 440G-T27261 page is one entry in it. The index sits one level above this page in the site tree.