This page documents catalog number 440G-T27248, which belongs to the 440G TLS-GD2 guard locking family. The point worth stating first is what the published selection matrix does not cover: this number is not printed in the matrix rows that assign type, solenoid voltage, entry and actuator, so those four attributes are not claimed here. The shared family figures below are established and quoted; the combination is to be read from the nameplate and the Rockwell catalog before the order is confirmed.
The published selection matrix is the document that assigns type, coil, entry and actuator to each number, and it is complete for the rows it prints. This number sits outside those rows, which is a statement about the matrix rather than about the switch: the hardware exists, the number is in the range, and the four assignment marks are on the unit itself.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
Where the matrix stops. The selection table is organised by type, coil voltage, actuator and entry, and each cell carries one catalog number. Numbers outside the table are not errors: they are the same hardware reached through a different ordering path, or a series that post dates the printed table. The practical consequence is that a quotation request for one of them needs the nameplate, not a lookup.
How to establish the combination. Four marks settle it without guesswork. The nameplate carries the complete catalog number and the switch type. The solenoid coil is marked with its voltage on the coil body. The entry is visible: an M20 thread, a 1/2 inch NPT adaptor or a 12-pin M23 receptacle. The actuator, where one is supplied, is the standard 440G-A27011, the fully flexible 440G-A27143, or one of the flat types ordered separately. Reading those four marks answers the question the matrix would have answered.
Why the family figures still apply. The holding force, contact ratings, solenoid power, actuation limits, ingress rating and maintenance intervals are properties of the TLS-GD2 mechanism rather than of any one catalog number, so they hold for every number in the range including this one. What changes with the number is the contact configuration of the chosen type, the coil voltage, the entry and whether an actuator ships in the box.
Nearest numbers in the range that the matrix does place are 440G-T27247, 440G-T27246, 440G-T27251, each documented on its own page, so the attribute pattern of this number can be checked against them before an order is placed.
Conduit practice. The entry choice follows the plant rather than the switch: an M20 thread is the metric default, the 1/2 inch NPT adaptor exists for North American conduit and hubs, and the M23 connector suits machines built as modules and tested before shipment. Getting this wrong costs an adaptor and a re-termination, and on a stainless washdown machine it can cost the IP69K rating as well.
The rest of the TLS-GD2 range is documented page by page on this site, including the numbers whose type, solenoid, entry and actuator the matrix does state. Where a buyer needs certainty on this one, the honest answer is a nameplate photograph rather than a guess, and that is what this page asks for.
| Parameter | Value |
| Catalog number | 440G-T27248 |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T27248 the figures above apply as printed.
Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T27248 the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27248 the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T27248 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no price is stated. The family figures are quoted from the TLS-GD2 installation instructions; the four attributes that vary by catalog number are left open on this page because the published matrix does not carry this number.
Every module in this family carries a green and red module-status indicator, a network-status indicator and per-channel yellow or red status, all on the logic side, so a technician diagnoses a channel from the face of the module rather than from a wiring diagram. 440G-T27248 is the number described on this page.
Twelve of the 86 440G records carried on this site, ordered by how close their codes sit to this one. This page is 440G-T27248.
This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 440G-T27248 page is one entry in it. It is the entry point used when a project list is assembled group by group.