This page documents catalog number 440G-T27203, which belongs to the 440G TLS-GD2 guard locking family. The point worth stating first is what the published selection matrix does not cover: this number is not printed in the matrix rows that assign type, solenoid voltage, entry and actuator, so those four attributes are not claimed here. The shared family figures below are established and quoted; the combination is to be read from the nameplate and the Rockwell catalog before the order is confirmed.
It is worth saying plainly what a page like this can and cannot do. It can give the family figures that every TLS-GD2 shares, and it can point to the sibling numbers whose assignment is published. It cannot tell a buyer which coil is inside a box that left the factory years ago, and a page that guessed would be worse than one that says so.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
Start from the guard, not the number. Full body access needs the escape release series. A guard that must stay locked after the supply fails needs power to lock and the caution that goes with it. A washdown cell needs the IP69K condition met with rated glands. A modular machine built and tested before shipment wants a connector rather than a gland. Those four questions pick the number; the number does not pick the guard.
What the contact set implies for the safety circuit. The TLS-1 and TLS-2 types carry three N.C. safety contacts with direct opening action and two N.O. auxiliary contacts, one of them monitoring the solenoid. The TLS-3 type carries four N.C. safety contacts and one N.O. auxiliary. A dual-channel safety input can be fed from either type; what differs is how much of the contact set remains available for diagnostics once the solenoid has taken its share.
How to establish the combination. Four marks settle it without guesswork. The nameplate carries the complete catalog number and the switch type. The solenoid coil is marked with its voltage on the coil body. The entry is visible: an M20 thread, a 1/2 inch NPT adaptor or a 12-pin M23 receptacle. The actuator, where one is supplied, is the standard 440G-A27011, the fully flexible 440G-A27143, or one of the flat types ordered separately. Reading those four marks answers the question the matrix would have answered.
Nearest numbers in the range that the matrix does place are 440G-T27186, 440G-T27184, 440G-T27233, each documented on its own page, so the attribute pattern of this number can be checked against them before an order is placed.
Ip69k glands. IP69K is conditional in the published text: it requires appropriate IP rated glands or a cordset. A switch with the correct housing and a plain cable entry is an IP67 device in practice, and washdown areas are where that distinction gets discovered. The condition applies to the M20 entry, the 1/2 inch NPT adaptor and the M23 connector equally.
The rest of the TLS-GD2 range is documented page by page on this site, including the numbers whose type, solenoid, entry and actuator the matrix does state. Where a buyer needs certainty on this one, the honest answer is a nameplate photograph rather than a guess, and that is what this page asks for.
| Parameter | Value |
| Catalog number | 440G-T27203 |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T27203 the figures above apply as printed.
Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T27203 the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27203 the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T27203 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no price is stated. The family figures are quoted from the TLS-GD2 installation instructions; the four attributes that vary by catalog number are left open on this page because the published matrix does not carry this number.
This page links twelve of the 86 440G records on this site; the closest rating codes come first. This page is 440G-T27203.
For the surrounding range, open the Allen Bradley Other PLC catalogue index — 440G-T27203 is listed there beside the rest of the other-PLC group. The index sits one level above this page in the site tree.