Allen Bradley Guardmaster 440G-T27124 / 440GT27124

China Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier
Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier Allen Bradley Guardmaster 440G-T27124 / 440GT27124 supplier

Large Image :  Allen Bradley Guardmaster 440G-T27124 / 440GT27124

Product Details:

Place of Origin: Made in DOMINICAN REP
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Guardmaster 440G-T27124 / 440GT27124

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $190.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

440G-T27124

This page documents catalog number 440G-T27124, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-1 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to release with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 110 V ac/dc solenoid supply, 1/2 inch NPT adaptor, and no actuator supplied. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.

What the switch is and what it carries

FieldValue
StandardsISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet
Safety classificationType 2 interlocking device with guard locking and low coding (tongue) per ISO 14119
Holding force Fmax1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts
Holding force Fzh1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts
Releasable load100 N (22.5 lbf) maximum
Solenoid power7 W typical at 100 percent duty
Escape release button50 N (11.25 lbf) maximum, escape release versions only
Thermal current10 A; rated insulation voltage 500 V
SwitchingA600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc
Actuation160 mm/s maximum, 100 mm/min minimum, 1 cycle per second
Operating radius160 mm minimum, 80 mm with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations at 100 mA load
EnclosureIP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K
Temperatureminus 20 to plus 60 C
Weight400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator

What this catalog number selects

AttributeValue
TypeTLS-1
Locking principlepower to release
Safety contacts3 N.C. direct opening action
Auxiliary contacts2 N.O., one of them used for solenoid monitoring
Solenoid supply110 V ac/dc
Actuatorno actuator supplied
Entry1/2 inch NPT adaptor

Where this number sits in the range

The other numbers in the same TLS-1 110 V ac/dc group are 440G-T27124 (1/2 inch NPT adaptor, no actuator supplied), 440G-T27172 (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted). At the same coil, entry and actuator the power to lock version is 440G-T27132, and the 230 V ac/dc coil version is 440G-T27123.

Why this combination exists

Holding force. The two holding force figures in the published table are not interchangeable. Fmax is what the lock survives: 1,950 N with plastic pins and 2,600 N with steel bolts. Fzh is what it holds with acceptable deformation, at 1,500 N and 2,000 N. A guard sized against Fmax alone will still open under a heavy impact, because the deformation allowance is the number that describes normal use.

Power to release logic. Power to release means the guard is locked whenever the solenoid is unpowered, and the guard opens only when a signal reaches the solenoid. The published note is that this signal can come from CU1 electronic timer relays or CU2 stopped motion detectors, which is the reason the type exists: machines that do not stop immediately need the guard to stay locked until motion is actually gone. This page documents 440G-T27124.

Series monitoring. Monitoring the safety contacts and the solenoid feedback in series is the default configuration, and the publication is specific about what makes it work: jumpers in place, pins 4 and 6 on the 12-pin M23 for the TLS-1 and TLS-2, pins 4 and 6 plus 7 and 8 for the TLS-3. Independent monitoring is a different configuration, not a better one, and it requires the 12-wire cordset 889M-F12AH with the jumpers between 12 and 41 removed, plus 22 and 51 on the TLS-3.

The rear escape release is not part of 440G-T27124. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.

Environment, mounting and maintenance of the TLS-GD2 switch

ParameterValue
Catalog number440G-T27124
Enclosure type ratingIP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset
Operating temperature-20...+60 °C (-4...+140 °F)
Housing and actuator materialHousing UL-approved glass-filled PBT; actuator stainless steel
Weight400 g (0.88 lb)
Body length and hole spacing126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes
Mounting bolts, max torque1.4 N·m (12.39 lb·in)
Lid screws, max torque1.2 N·m (10.62 lb·in)
Terminal screws, max torque1.02 N·m (9 lb·in)
Break contact force, min30 N (7 lbf)
Actuation speed100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum
Actuation frequency, max1 cycle/s
Operating radius, min160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations

Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T27124 the figures above apply as printed.

Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T27124 the figures above apply as printed.

IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27124 the gland fitted at installation is what decides whether the claim holds.

The figures above are family values from 440G-IN022. For 440G-T27124 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.

The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27124 as well.

No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. This page documents 440G-T27124.

Site tree: the Allen Bradley Other PLC index carries 440G-T27124 together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. The index sits one level above this page in the site tree.