Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier Allen Bradley Guardmaster 440G-T27121 / 440GT27121 supplier

Large Image :  Allen Bradley Guardmaster 440G-T27121 / 440GT27121

Product Details:

Place of Origin: Made in DOMINICAN REP
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Guardmaster 440G-T27121 / 440GT27121

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $174.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

440G-T27121

This page documents catalog number 440G-T27121, a TLS-GD2 positive-mode tongue-operated guard locking switch. The TLS-1 variant locks a machine guard closed until power is isolated and keeps the isolation in place while the guard is open. This number is power to release with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 24 V ac/dc solenoid supply, M20 conduit entry, and no actuator supplied. The figures below are quoted from the TLS-GD2 installation instructions and from the published selection matrix, not inferred.

What the switch is and what it carries

FieldValue
StandardsISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet
Safety classificationType 2 interlocking device with guard locking and low coding (tongue) per ISO 14119
Holding force Fmax1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts
Holding force Fzh1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts
Releasable load100 N (22.5 lbf) maximum
Solenoid power7 W typical at 100 percent duty
Escape release button50 N (11.25 lbf) maximum, escape release versions only
Thermal current10 A; rated insulation voltage 500 V
SwitchingA600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc
Actuation160 mm/s maximum, 100 mm/min minimum, 1 cycle per second
Operating radius160 mm minimum, 80 mm with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations at 100 mA load
EnclosureIP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K
Temperatureminus 20 to plus 60 C
Weight400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator

What this catalog number selects

AttributeValue
TypeTLS-1
Locking principlepower to release
Safety contacts3 N.C. direct opening action
Auxiliary contacts2 N.O., one of them used for solenoid monitoring
Solenoid supply24 V ac/dc
Actuatorno actuator supplied
EntryM20 conduit entry

Where this number sits in the range

The other numbers in the same TLS-1 24 V ac/dc group are 440G-T27121 (M20 conduit entry, no actuator supplied), 440G-T27233 (12-pin M23 connector, no actuator supplied).

Why this combination exists

Field wiring. The UL508 section is three constraints: 75 C copper conductors only, one conduit entrance for field connections, and wiring rated no lower than the ambient where the switch sits in a hot panel. Those constraints decide terminal space and cable selection before the switch type is chosen, and they are the reason an NPT adaptor sometimes wins over a plain metric entry on a US-built machine.

Power to release logic. Power to release means the guard is locked whenever the solenoid is unpowered, and the guard opens only when a signal reaches the solenoid. The published note is that this signal can come from CU1 electronic timer relays or CU2 stopped motion detectors, which is the reason the type exists: machines that do not stop immediately need the guard to stay locked until motion is actually gone. 440G-T27121 is the number described on this page.

Rotatable head. The head carries two entry slots and rotates to give four actuator entry points, with a blanking plug for the slot that is not used. That is real installation freedom on a guard that is hard to align, and it also imposes a duty: the unused slot has to be plugged, because an open slot invites a second actuator and the publication warns that spare actuators compromise the integrity of the safety system.

The rear escape release is not part of 440G-T27121. That option is published as a separate series, the T21B numbers, where the letter P in the catalog number denotes power to release with escape release. A guard with full body access needs that series, and the distinction is worth checking before a purchase order is raised on a T27 number.

Environment, mounting and maintenance of the TLS-GD2 switch

ParameterValue
Catalog number440G-T27121
Enclosure type ratingIP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset
Operating temperature-20...+60 °C (-4...+140 °F)
Housing and actuator materialHousing UL-approved glass-filled PBT; actuator stainless steel
Weight400 g (0.88 lb)
Body length and hole spacing126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes
Mounting bolts, max torque1.4 N·m (12.39 lb·in)
Lid screws, max torque1.2 N·m (10.62 lb·in)
Terminal screws, max torque1.02 N·m (9 lb·in)
Break contact force, min30 N (7 lbf)
Actuation speed100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum
Actuation frequency, max1 cycle/s
Operating radius, min160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143
Mechanical life1,000,000 operations

The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T27121 the figures above apply as printed.

Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T27121 the figures above apply as printed.

IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T27121 the gland fitted at installation is what decides whether the claim holds.

The figures above are family values from 440G-IN022. For 440G-T27121 the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.

The page states no performance level for a machine, no guard cycle count and no cable length beyond the published cordsets, because those follow from the application and not from the catalog number. Where a figure is missing here it is missing from the source publication for 440G-T27121 as well.

No service life claim and no price is implied. Contacts, solenoid and environmental limits are quoted from the TLS-GD2 installation instructions, and the type, solenoid, entry and actuator assignment is quoted from the published selection matrix row that carries this catalog number. 440G-T27121 is the number described on this page.

Related catalog numbers in the 440G range

Twelve of the 86 440G records carried on this site, ordered by how close their codes sit to this one. This page is 440G-T27121.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 440G-T27121 page is one entry in it. Reach it directly if the suffix on this record still needs confirming against a sibling.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)