This page documents catalog number 440G-T21BGPT-4B, a TLS-GD2 positive-mode tongue-operated guard locking switch with the rear escape release. It is TLS-1 with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 110 V ac/dc solenoid supply, 1/2 inch NPT adaptor, and GD2 standard actuator 440G-A27011 fitted. The escape release exists so that a person locked inside a machine guard can release the lock from within the hazardous area; the switch is mounted with that button reachable from the guarded side. The figures below are quoted from the TLS-GD2 installation instructions and the published selection matrix.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-1 |
| Locking principle | power to release |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 110 V ac/dc |
| Actuator | GD2 standard actuator 440G-A27011 fitted |
| Entry | 1/2 inch NPT adaptor |
| Escape release | fitted, 50 N maximum operating force |
Within the escape release series the TLS-1 at 110 V ac/dc covers 440G-T21BGPT-4B (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted), 440G-T21BGPM-4B (M20 conduit entry, GD2 standard actuator 440G-A27011 fitted). The four contact version of the same coil, entry and actuator is 440G-T21BGPT-5B. The same switch without the escape release is published as 440G-T27172, which is the number to compare when the guard does not need full body access, and the 24 V ac/dc coil version is 440G-T21BGPT-1B.
Escape release. The escape release is a button on the rear of the switch, published at 50 N maximum operating force, intended for guards that a person can enter. The switch is installed so that button is reachable from inside the hazardous area, which makes the mounting side part of the safety function: fit it facing the wrong way and the release still exists, but nobody trapped can reach it. The catalog number covered on this page is 440G-T21BGPT-4B.
Power to release logic. Power to release means the guard is locked whenever the solenoid is unpowered, and the guard opens only when a signal reaches the solenoid. The published note is that this signal can come from CU1 electronic timer relays or CU2 stopped motion detectors, which is the reason the type exists: machines that do not stop immediately need the guard to stay locked until motion is actually gone. The catalog number covered on this page is 440G-T21BGPT-4B.
Series monitoring. Monitoring the safety contacts and the solenoid feedback in series is the default configuration, and the publication is specific about what makes it work: jumpers in place, pins 4 and 6 on the 12-pin M23 for the TLS-1 and TLS-2, pins 4 and 6 plus 7 and 8 for the TLS-3. Independent monitoring is a different configuration, not a better one, and it requires the 12-wire cordset 889M-F12AH with the jumpers between 12 and 41 removed, plus 22 and 51 on the TLS-3.
The sliding bolt actuator 440G-A27163 is published as not to be used with the escape release. That is a mechanical conflict rather than a preference, and a guard that needs both full body access and a sliding bolt has to be solved with a different interlock arrangement rather than by fitting both accessories. The catalog number covered on this page is 440G-T21BGPT-4B.
| Parameter | Value |
| Catalog number | 440G-T21BGPT-4B |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
The unit is not a mechanical stop. Publication 440G-IN022 requires guard stops and guides to be fitted, so the weight of the guard and the impact of closing it are carried by the door hardware and never by the actuator or the head. The switch also has to sit on a metal surface that provides a low-impedance connection to the machine earthing system, which makes the mounting bolts part of the earth path rather than a convenience. The maxima are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws; a screw driven past its figure distorts the glass-filled PBT housing and moves the head alignment the actuator depends on. For 440G-T21BGPT-4B the figures above apply as printed.
Maintenance is prescribed at two frequencies. Weekly, the switching circuit is operated and checked, the casing is inspected for signs of abuse or tampering, and a damaged unit is replaced rather than repaired. At least every six months the power is isolated, the lid removed, every terminal checked for tightness, fine dirt cleaned out, the actuator, cam assembly and contacts inspected for wear or oxidation, the covers refitted at the specified torques, the power reinstated, operation rechecked and the tamper-evident varnish reapplied to the screws. The same publication states that any malfunction or damage means the switch is replaced before the machine is allowed to run. For 440G-T21BGPT-4B the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T21BGPT-4B the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T21BGPT-4B the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no cable length beyond the published cordsets is stated, because those follow from the application rather than from the catalog number. Where a figure is absent here it is absent from the source publication for 440G-T21BGPT-4B as well.
No service life claim and no price is implied. Contacts, solenoid and environmental limits come from the TLS-GD2 installation instructions; the type, coil, entry and actuator assignment comes from the selection matrix row that carries this catalog number. The catalog number covered on this page is 440G-T21BGPT-4B.
Group index: Allen Bradley Other PLC. 440G-T21BGPT-4B is filed under that heading in the site's own product tree. Reach it directly if the suffix on this record still needs confirming against a sibling.