Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 440G-T21BGPL-1B, a TLS-GD2 positive-mode tongue-operated guard locking switch with the rear escape release. It is TLS-1 with position monitoring 2 N.C. and 1 N.O. plus lock monitoring 1 N.C. and 1 N.O., a 24 V ac/dc solenoid supply, 12-pin M23 connector, and GD2 standard actuator 440G-A27011 fitted. The escape release exists so that a person locked inside a machine guard can release the lock from within the hazardous area; the switch is mounted with that button reachable from the guarded side. The figures below are quoted from the TLS-GD2 installation instructions and the published selection matrix.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1, plus EN 1088, NFPA 79 and ANSI B11.19 in the family sheet |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | 1,950 N (488 lbf) with plastic pins, 2,600 N (585 lbf) with steel bolts |
| Holding force Fzh | 1,500 N (337 lbf) with plastic pins, 2,000 N (450 lbf) with steel bolts |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum, escape release versions only |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 5 mA at 5 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second |
| Operating radius | 160 mm minimum, 80 mm with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations at 100 mA load |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands or cordset required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Attribute | Value |
| Type | TLS-1 |
| Locking principle | power to release |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one of them used for solenoid monitoring |
| Solenoid supply | 24 V ac/dc |
| Actuator | GD2 standard actuator 440G-A27011 fitted |
| Entry | 12-pin M23 connector |
| Escape release | fitted, 50 N maximum operating force |
Within the escape release series the TLS-1 at 24 V ac/dc covers 440G-T21BGPL-1B (12-pin M23 connector, GD2 standard actuator 440G-A27011 fitted), 440G-T21BGPT-1B (1/2 inch NPT adaptor, GD2 standard actuator 440G-A27011 fitted). The four contact version of the same coil, entry and actuator is 440G-T21BGPL-2B. The same switch without the escape release is published as 440G-T27234, which is the number to compare when the guard does not need full body access.
Escape release. The escape release is a button on the rear of the switch, published at 50 N maximum operating force, intended for guards that a person can enter. The switch is installed so that button is reachable from inside the hazardous area, which makes the mounting side part of the safety function: fit it facing the wrong way and the release still exists, but nobody trapped can reach it. This page covers 440G-T21BGPL-1B and its ordering options.
Rotatable head. The head carries two entry slots and rotates to give four actuator entry points, with a blanking plug for the slot that is not used. That is real installation freedom on a guard that is hard to align, and it also imposes a duty: the unused slot has to be plugged, because an open slot invites a second actuator and the publication warns that spare actuators compromise the integrity of the safety system.
Actuation geometry. The published actuation speeds bracket the mechanism at both ends: 160 mm/s maximum and 100 mm/min minimum. A guard that closes slower than the minimum does not actuate reliably, which is why a heavy hinged door on a gas strut needs its closing time measured rather than assumed. The minimum operating radius is 160 mm, or 80 mm with the flexible actuator.
The sliding bolt actuator 440G-A27163 is published as not to be used with the escape release. That is a mechanical conflict rather than a preference, and a guard that needs both full body access and a sliding bolt has to be solved with a different interlock arrangement rather than by fitting both accessories. This page covers 440G-T21BGPL-1B and its ordering options.
| Parameter | Value |
| Catalog number | 440G-T21BGPL-1B |
| Enclosure type rating | IP66, IP67, IP69K; IP69K requires appropriate IP-rated glands or cordset |
| Operating temperature | -20...+60 °C (-4...+140 °F) |
| Housing and actuator material | Housing UL-approved glass-filled PBT; actuator stainless steel |
| Weight | 400 g (0.88 lb) |
| Body length and hole spacing | 126 mm (4.96 in.) overall, 105 mm (4.13 in.) between mounting holes |
| Mounting bolts, max torque | 1.4 N·m (12.39 lb·in) |
| Lid screws, max torque | 1.2 N·m (10.62 lb·in) |
| Terminal screws, max torque | 1.02 N·m (9 lb·in) |
| Break contact force, min | 30 N (7 lbf) |
| Actuation speed | 100 mm (3.94 in.) per minute minimum, 160 mm (6.29 in.)/s maximum |
| Actuation frequency, max | 1 cycle/s |
| Operating radius, min | 160 mm (6.3 in.), 80 mm (3.15 in.) with the flexible actuator 440G-A27143 |
| Mechanical life | 1,000,000 operations |
Mounting rules come from 440G-IN022 and they are mechanical rather than electrical. The switch is not a mechanical stop, so guard stops and guides have to be fitted and the impact of a closing guard must not reach the head or the actuator. The mounting surface must be metal with a low-impedance connection to the machine earthing system, and the bolts that hold the body are therefore part of that path. Tightening figures are 1.4 N·m for the mounting bolts, 1.2 N·m for the lid screws and 1.02 N·m for the terminal screws, and over-torque on a glass-filled PBT housing distorts the body enough to shift the four-entry head out of alignment. For 440G-T21BGPL-1B the figures above apply as printed.
Two maintenance intervals are printed, and both are part of the warranty terms. Weekly: operate and check the switching circuit, look for abuse or tampering, inspect the casing for damage and replace a damaged unit. At least every six months: isolate all power, remove the lid, check every terminal for tightness, clean out accumulated fine dirt, inspect the actuator, the cam assembly and the contacts for wear or oxidation, refit the covers at the specified torques, reinstate the power, check operation and reapply tamper-evident varnish to the screws. Repair is not offered in that document; a malfunctioning or damaged switch is replaced before the machine may run again. For 440G-T21BGPL-1B the figures above apply as printed.
IP69K is a claim about the gland as much as about the housing. 440G-IN022 annotates the rating with the condition that appropriate IP-rated glands or a suitable cordset are used, so a switch wired through an ordinary cable entry should be read as an IP66/IP67 device in service. The sealed housing needs no cabinet of its own; a washdown or corrosive atmosphere can still justify one, but that is a plant decision rather than a product limitation. On 440G-T21BGPL-1B the gland fitted at installation is what decides whether the claim holds.
The figures above are family values from 440G-IN022. For 440G-T21BGPL-1B the attributes that do change with the catalog number are the contact set, the solenoid voltage and the entry and actuator combination, and those are stated in the tables earlier on this page.
No performance level for a machine, no guard cycle count and no cable length beyond the published cordsets is stated, because those follow from the application rather than from the catalog number. Where a figure is absent here it is absent from the source publication for 440G-T21BGPL-1B as well.
No service life claim and no price is implied. Contacts, solenoid and environmental limits come from the TLS-GD2 installation instructions; the type, coil, entry and actuator assignment comes from the selection matrix row that carries this catalog number. This page covers 440G-T21BGPL-1B and its ordering options.
Site tree: the Allen Bradley Other PLC index carries 440G-T21BGPL-1B together with the other entries of the other-PLC group, which is where a catalogue walk usually starts.