Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S

China Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier
Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S supplier

Large Image :  Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Kinetix 6000 2094-AC05-M01-S / 2094AC05M01S

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1647.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

2094-AC05-M01-S

This page documents catalog number 2094-AC05-M01-S, a Kinetix 6000 integrated axis module (IAM) on the 230 V class: 3 kW converter with a 9 A inverter. The IAM is the module that supplies the DC bus for the rail and carries one inverter axis of its own, so it is both the power supply and the first axis of a multi-axis system.

Catalog number and published rating

FieldValue
Catalog number2094-AC05-M01-S
FamilyKinetix 6000 multi-axis servo drive, Bulletin 2094
Module typeIAM - integrated axis module, converter plus one inverter axis
Voltage class230 V
Trailing charactersS
Safe torque offpresent, the -S versions in the catalog table carry it
Converter rating3 kW
Inverter rating9 A
DC bus capacitance270 uF

What the module does on a rail

A Kinetix 6000 system is built on a power rail rather than wired module to module. The IAM module is the leader: it converts three-phase AC to a DC bus, regulates that bus, and carries the first inverter axis. AM modules bolt onto the same rail, take the bus through the rail, and each adds one axis. The mounting order rule is published rather than optional: IAM, then AM and IPIM modules ordered by power utilisation from highest to lowest, then the shunt and the slot fillers.

For 2094-AC05-M01-S, power utilisation means the average power the axis consumes in its cycle, not its nameplate rating. A rail ordered by nameplate horsepower and mounted in catalog order can put a small axis to the left of a large one, and the published instruction says the opposite order is what the bus expects.

Peak current and the series question

On 2094-AC05-M01-S the published peak behaviour is one of two, and which of them applies is fixed by the series of the module: the 460 V modules are published with two peak behaviors. Series A modules are factory configured at 150 percent of continuous inverter current, and series B and later modules can be programmed for up to 250 percent on the same continuous rating, with the M05 rating capped at 200 percent. The enhancement is not available until it is enabled in the drive configuration, so a module that is physically a series B unit still behaves as a 150 percent unit out of the box.

For 2094-AC05-M01-S that distinction is what makes two catalog numbers with the same continuous power behave differently on an acceleration-limited cycle. A machine sized on continuous torque and then asked for a short, hard move is sized on the peak column, and the peak column depends on both the module and the series of the module in the panel.

Converter, bus and power cycling

The IAM module is the only module on the rail that connects to the AC line, so the line-side protection, the line filter or LIM module and the DC bus capacitance all belong to it. The published bus capacitance for this converter is 270 uF where the table gives it, and the module carries that capacitance into the power-cycling limit: the published figure is expressed per 10,000 uF, so a rail with more capacitance cycles fewer times per minute.

For this module the main AC input power cycling figure is 4.30 cycles per minute at 10,000 uF, and the manual works the arithmetic in the open: a four-axis system with 2,000 uF of total capacitance multiplies that figure by 10,000 divided by 2,000, then caps it at the published axes-per-system limit. A machine that power-cycles its drive more often than that is a machine that will see bus pre-charge faults rather than drive faults.

Control power is a separate feed. The IAM module needs single-phase control power for its logic, from 95 to 264 V AC at 47 to 63 Hz. On the 230 V IAM the control power is taken line-to-line from the three-phase input, with neither leg bonded to ground or neutral; on the 460 V IAM the published instruction is a step-down transformer for the single-phase control input. That is the difference that catches panel builders who copy a 230 V drawing onto a 460 V rail.

The rail also publishes a control-power current table by axis count: an IAM alone draws 0.36 A at 220 to 230 V, and each additional AM module adds roughly 0.28 A, up to 2.31 A for an IAM with seven AM modules. That is the number to size the control transformer against, not the drive nameplate.

Wiring, brake and analog interface

The published termination for this module is 6 mm2 (10 AWG) maximum on the motor power cable at a 10 mm strip length and 0.5 to 0.6 N-m. The AC input terminals on a 230 V IAM take 2.5 mm2 (14 AWG) at a 10 mm strip and 0.5 to 0.6 N-m, which is a smaller terminal than the motor connection on the same module and a frequent source of a wrong lug on a panel.

The motor brake interface is a relay output on MBRK+ and MBRK-, limited to 30 V DC, and the published brake current limit for this module is 1.0 A on series A and 3.0 A on series C and later. A brake coil above that limit needs an interposing relay, and a brake wired directly to a module that cannot carry the coil current is a brake that releases late or not at all.

Every IAM and AM module, 2094-AC05-M01-S included, carries two analog outputs that can be assigned to drive variables. On the -S versions the output range is 0 to +10 V, on the versions without the safe torque-off feature it is 0 to +5 V, the resolution is +/- 11 bits, the output can source 2 mA, and the bandwidth is DC to 7.2 kHz at 3 dB. A chart recorder or a drive-to-drive torque reference wired to the wrong variant saturates at half scale, which reads as a tuning problem rather than as a wiring one.

The IAM module carries the ground jumper for the whole rail, and it has to match the supply grounding. For this class the published settings are P15 and P16 for the grounded configuration and P15 and P17 for the ungrounded one, with grounded as the default. The jumper is reached by swinging the front panel open to the right after removing the top and bottom screws; the panel is not removable, because the status indicators are connected to the module by a ribbon cable that acts as the hinge. Replacing the panel takes 1.6 N-m (14 lb-in) on its two screws, and the jumper setting is a commissioning record that belongs in the panel documentation.

What the string does and does not settle

On 2094-AC05-M01-S the string settles the voltage class, the converter or axis rating, and the trailing characters, which in the catalog table separate the version with the safe torque-off feature from the version without it. It does not settle the motor, the feedback, the line filter or the LIM module: those are selected against the axis and the supply, and the rail configuration decides whether a shunt module is internal or a separate 2094-BSP2 on the same rail.

The module is a rail-mounted power stage, not a stand-alone drive: it takes the DC bus from the IAM on the left and the Sercos fiber from the ring, and mounts in a fixed order with the IAM, then the axis modules and the IPIM, ordered by power utilization from highest to lowest.

No lifecycle statement and no price is implied for 2094-AC05-M01-S. The converter and inverter ratings, continuous power, peak current behavior, power cycling, termination, brake current and analog output figures are quoted from the Kinetix 6000 user manual, publication 2094-UM001, for this module family.

>

Related catalog numbers in the 2094 range

This page links twelve of the 66 2094 records on this site; the closest rating codes come first. This page is 2094-AC05-M01-S.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 2094-AC05-M01-S is listed there beside the rest of the other-PLC group. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)