Product Details:
Payment & Shipping Terms:
|
This page documents the 1606-XLSRED80, a member of the Bulletin 1606 switched-mode power supply range: DC 12...28 V output at 2x 40 A / 80 A, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XLSRED80 |
| Product family | Bulletin 1606 switched-mode power supply |
| Output voltage, nominal | DC 12...28 V |
| Output current, nominal | 2x 40 A / 80 A |
| Output power | no output power printed |
| Input, AC | not printed for this string |
| Input, DC | DC 8.4...36.4 V |
| Feature or limitation flag | dual-input MOSFET redundancy module |
| Series attribute | Published value |
| Series | 1606-XL Power Supply (legacy line) |
| Power range | 60...960 W |
| Overload / boost | not published for this line in the current technical data |
| Reserve current | not published for this line in the current technical data |
| Efficiency, typical | not published for this line in the current technical data |
| Operating temperature | not published for this line in the current technical data |
| Terminals | screw terminals |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the 2x 40 A / 80 A output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
Sizing from this row means three numbers that are rarely written down together: the continuous rail load against 2x 40 A / 80 A, the inrush allowance taken from the published reserve of the line, and the heat the unit leaves in the enclosure. The third one is the one that decides whether the cabinet needs a fan, and it follows from the efficiency band for this frame rather than from the watts figure alone. The input current at the lowest point of the published window is the fourth, and it is the one the branch device is sized against.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLSRED80, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current. This page covers 1606-XLSRED80 and its ordering options.
A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line. This page covers 1606-XLSRED80 and its ordering options.
Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve. This page covers 1606-XLSRED80 and its ordering options.
This string publishes a DC input window as well as an AC one. DC 8.4...36.4 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.
The feature flag on this row reads: dual-input MOSFET redundancy module. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
This string belongs to the redundancy group. Its job is to decouple two feeds so that one supply failing does not drag the other down, and it is rated in load current rather than in output watts. The group is selected by the load and by whether the two feeds share a source, and the module is always a separate enclosure beside the supplies rather than a stage inside one.
A substitution audit for 1606-XLSRED80 runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.
The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench. This page covers 1606-XLSRED80 and its ordering options.
What is 1606-XLSRED80? 1606-XLSRED80 is a switched-mode power supply in the Bulletin 1606 range: DC 12...28 V output at 2x 40 A / 80 A, no output power printed, with an input window printed in the selection table.
Is 1606-XLSRED80 current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XLSRED80? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
This number is an accessory or a legacy-line member rather than a stand-alone supply row: dual-input MOSFET redundancy module. Its own catalog string therefore carries the family and the function rather than an output rating, and it is selected by the supply it is paired with - the current rating of that supply, the rail it serves and the mounting it needs - instead of by a watts figure. That is why the selection row above marks the electrical fields the publication does not print for this catalog number.
No price and no lead time is implied on this page. For 1606-XLSRED80 the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
Twelve of the 129 1606 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1606-XLSRED80.
Group index: Allen Bradley Other PLC. 1606-XLSRED80 is filed under that heading in the site's own product tree. The index sits one level above this page in the site tree.