Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5 supplier

Large Image :  Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLSBAT5 / 1606XLSBAT5

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $247.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLSBAT5

This page documents the 1606-XLSBAT5, a member of the Bulletin 1606 switched-mode power supply range: 12 V battery output at 5 Ah, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLSBAT5
Product familyBulletin 1606 switched-mode power supply
Output voltage, nominal12 V battery
Output current, nominal5 Ah
Output powerno output power printed
Input, ACnot printed for this string
Input, DCnot printed for this string
Feature or limitation flagreplacement battery for 1606-XLS240-UPSC

Where this model sits in the XL line

Series attributePublished value
Series1606-XL Power Supply (legacy line)
Power range60...960 W
Overload / boostnot published for this line in the current technical data
Reserve currentnot published for this line in the current technical data
Efficiency, typicalnot published for this line in the current technical data
Operating temperaturenot published for this line in the current technical data
Terminalsscrew terminals
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the 5 Ah output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

Three calculations follow from the row above. The output load is the sum of everything on the rail against 5 Ah, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the published window, not at nominal mains, because that is where the current is highest.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLSBAT5, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers to 1606-XLSBAT5 in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating.

Efficiency is a thermal number before it is an energy number. A 90 to 95 percent efficiency figure on a 480 W supply leaves 25 to 48 W of heat inside the enclosure, which is the difference between a sealed cabinet that holds temperature and one that needs forced ventilation. The efficiency band is published per series rather than per model, so the number to check is the one for the frame size that was ordered.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current.

The feature flag on this row reads: replacement battery for 1606-XLS240-UPSC. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

This string belongs to the battery-backed group. Battery modules, buffer modules and UPS units are rated in ampere-hours or in holdup time rather than in continuous watts, and they are selected from the load and from the ride-through the process needs. The charging circuit is part of the unit, so the battery string and the supply are matched as a pair rather than sized independently.

Checks before substituting another 1606 number

A substitution audit for this number runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.

Read this row against the panel it will feed rather than against the catalogue page: the output is what the rail needs, the reserve is what the inrush may borrow, the efficiency is what the cabinet must dissipate, and the input window is what the site must supply. A number that satisfies the first three and fails the fourth is a unit that is correct on paper and unusable on a low-line branch.

Questions this catalog number answers

What is 1606-XLSBAT5? 1606-XLSBAT5 is a switched-mode power supply in the Bulletin 1606 range: 12 V battery output at 5 Ah, no output power printed, with an input window printed in the selection table.

Is 1606-XLSBAT5 current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLSBAT5? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

Role of this string in the range

This number is an accessory or a legacy-line member rather than a stand-alone supply row: replacement battery for 1606-XLS240-UPSC. Its own catalog string therefore carries the family and the function rather than an output rating, and it is selected by the supply it is paired with - the current rating of that supply, the rail it serves and the mounting it needs - instead of by a watts figure. That is why the selection row above marks the electrical fields the publication does not print for this catalog number.

No price and no lead time is implied on this page. For 1606-XLSBAT5 the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

This page links twelve of the 129 1606 records on this site; the closest rating codes come first. This page is 1606-XLSBAT5.