logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE

China Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier
Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE supplier

Large Image :  Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLS480EE / 1606XLS480EE

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $373.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLS480EE

This page documents the 1606-XLS480EE, a member of the Bulletin 1606 switched-mode power supply range (1606-XLS Performance Power Supply): 24 V output at 20 A, 480 W, with AC 200...240 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLS480EE
Product family1606-XLS Performance Power Supply
Output voltage, nominal24 V
Output current, nominal20 A
Output power480 W
Input, ACAC 200...240 V
Input, DCnot printed for this string
Feature or limitation flagnone printed

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLS1606-XLS Performance Power Supply
Digits480rated output power in watts
Voltage letterE24...28 V
Trailing suffixEregional unit for Europe

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XLS line

Series attributePublished value
Series1606-XLS Performance Power Supply
Power range80...960 W
Overload / boost150 % for 5 s
Reserve current50 % additional current
Efficiency, typical90.0...95.3 % typical depending on model
Operating temperature-25...+70 degC, derating above 60 degC
Terminalsspring terminals, screw terminals on the 960 W frame sizes
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the line that carries power factor correction, DC OK relay contacts and the highest efficiency in the bulletin. Against this string that means the 20 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

The rail load is the first number and it is 20 A; the second is the inrush the loads draw at switch-on, which the published reserve covers only for the time the line states; the third is the input current at the lowest point of the AC 200...240 V window, which is what the branch device has to carry without tripping on a cold start. A supply sized on nominal mains current alone fails the third check in winter.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLS480EE, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers in the XLS series are 1606-XLS120E,1606-XLS120EA, 1606-XLS180B, 1606-XLS240-UPS. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve. This entry is for 1606-XLS480EE.

The -3 and regional suffixes are input variants. A trailing numeric suffix on this bulletin marks an input or regional variant rather than a different output: 380...480 V AC three-phase builds and regional mains builds read the same output current from a different input window. Substituting one for the other across a project is an input-side change, and the output side of the panel does not have to be re-validated. This entry is for 1606-XLS480EE.

Dc input is a separate application, not an ac fallback. The DC-input members of this bulletin take 110...300 V DC or a battery-range window, and they exist for rail, vehicle and battery-backed panels. A DC input is not an AC supply with a rectifier bolted on the front: the input window, the inrush and the branch protection all change, and the string carries the DC figure explicitly. This entry is for 1606-XLS480EE.

At 480 W this row sits in the high-power frames. Above roughly 480 W the terminals change to the larger screw or push-in sets and the unit needs the clearance a full-depth cabinet gives it, which is the mechanical difference a drawing has to show. A supply of this size also turns the enclosure thermal calculation into the deciding one, because the loss inside the cabinet is now tens of watts.

Checks before substituting another 1606 number

The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five. This entry is for 1606-XLS480EE.

What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision. This entry is for 1606-XLS480EE.

Questions this catalog number answers

What is 1606-XLS480EE? 1606-XLS480EE is a 1606-XLS Performance Power Supply in the Bulletin 1606 range: 24 V output at 20 A, 480 W, with AC 200...240 V input.

Is 1606-XLS480EE current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLS480EE? The input current at the lowest voltage of the AC 200...240 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLS480EE the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Twelve of the 129 1606 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1606-XLS480EE.

Group index: Allen Bradley Other PLC. 1606-XLS480EE is filed under that heading in the site's own product tree. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)