Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS

China Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier
Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS supplier

Large Image :  Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLS480-UPS / 1606XLS480UPS

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $384.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLS480-UPS

This page documents the 1606-XLS480-UPS, a member of the Bulletin 1606 switched-mode power supply range (1606-XLS Performance Power Supply): DC 24 V output at 20 A, 600 W, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLS480-UPS
Product family1606-XLS Performance Power Supply
Output voltage, nominalDC 24 V
Output current, nominal20 A
Output power600 W
Input, ACnot printed for this string
Input, DCDC 22.5...30 V
Feature or limitation flagbattery DC-UPS, external 24 V battery 3.9...150 Ah

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLS1606-XLS Performance Power Supply
Digits480rated output power in watts
Trailing suffix-UPSa suffix not in the published table; read the printed description

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XLS line

Series attributePublished value
Series1606-XLS Performance Power Supply
Power range80...960 W
Overload / boost150 % for 5 s
Reserve current50 % additional current
Efficiency, typical90.0...95.3 % typical depending on model
Operating temperature-25...+70 degC, derating above 60 degC
Terminalsspring terminals, screw terminals on the 960 W frame sizes
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the line that carries power factor correction, DC OK relay contacts and the highest efficiency in the bulletin. Against this string that means the 20 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

The rail load is the first number and it is 20 A; the second is the inrush the loads draw at switch-on, which the published reserve covers only for the time the line states; the third is the input current at the lowest point of the published window, which is what the branch device has to carry without tripping on a cold start. A supply sized on nominal mains current alone fails the third check in winter.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLS480-UPS, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers in the XLS series are 1606-XLS120E,1606-XLS120EA, 1606-XLS180B, 1606-XLS240-UPS. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current. This page covers 1606-XLS480-UPS and its ordering options.

A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line. This page covers 1606-XLS480-UPS and its ordering options.

Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve. This page covers 1606-XLS480-UPS and its ordering options.

This string publishes a DC input window as well as an AC one. DC 22.5...30 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.

The feature flag on this row reads: battery DC-UPS, external 24 V battery 3.9...150 Ah. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

At 600 W this row sits in the high-power frames. Above roughly 480 W the terminals change to the larger screw or push-in sets and the unit needs the clearance a full-depth cabinet gives it, which is the mechanical difference a drawing has to show. A supply of this size also turns the enclosure thermal calculation into the deciding one, because the loss inside the cabinet is now tens of watts.

This string belongs to the battery-backed group. Battery modules, buffer modules and UPS units are rated in ampere-hours or in holdup time rather than in continuous watts, and they are selected from the load and from the ride-through the process needs. The charging circuit is part of the unit, so the battery string and the supply are matched as a pair rather than sized independently.

Checks before substituting another 1606 number

A substitution audit for 1606-XLS480-UPS runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.

What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision. This page covers 1606-XLS480-UPS and its ordering options.

Questions this catalog number answers

What is 1606-XLS480-UPS? 1606-XLS480-UPS is a 1606-XLS Performance Power Supply in the Bulletin 1606 range: DC 24 V output at 20 A, 600 W, with an input window printed in the selection table.

Is 1606-XLS480-UPS current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLS480-UPS? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLS480-UPS the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Of the 129 1606 records carried here, these twelve stand closest to this catalog number. This page is 1606-XLS480-UPS.

Site tree: the Allen Bradley Other PLC index carries 1606-XLS480-UPS together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)